Index: firmware/App/Modes/FPModes/StateFlushPermeate.c =================================================================== diff -u -r2d295ca85f19e95da42476a57ca6b4496baf980a -r9f1f5a95111b55ee99bbdcd60a2c8b4cc088237c --- firmware/App/Modes/FPModes/StateFlushPermeate.c (.../StateFlushPermeate.c) (revision 2d295ca85f19e95da42476a57ca6b4496baf980a) +++ firmware/App/Modes/FPModes/StateFlushPermeate.c (.../StateFlushPermeate.c) (revision 9f1f5a95111b55ee99bbdcd60a2c8b4cc088237c) @@ -157,7 +157,7 @@ // TODO update the default min duty cycle value after testing F32 currentDutyCyclePct = getCurrentBoostPumpDutyCyclePCT() > MIN_BOOST_PUMP_DUTY_CYCLE_PCT ? getCurrentBoostPumpDutyCyclePCT(): MIN_BOOST_PUMP_DUTY_CYCLE_PCT; - setBoostPumpTargetDutyCycle( currentDutyCyclePct ); + setBoostPumpTargetDutyCycle( currentDutyCyclePct, TRUE ); isTankFilled = TRUE; } } @@ -167,7 +167,7 @@ // set boost pump to closed loop when M4 closed. Added Tank fill check to avoid reset during initial transition if ( ( TRUE == isBoostPumpInstalled() ) && ( TRUE == isTankFilled ) ) { - setBoostPumpTargetPressure( PERMEATE_FLUSH_BOOST_PUMP_TGT_PSI ); + setBoostPumpTargetPressure( PERMEATE_FLUSH_BOOST_PUMP_TGT_PSI, TRUE ); isTankFilled = FALSE; } @@ -260,7 +260,7 @@ setValveState( P39_VALV, VALVE_STATE_OPEN ); if ( TRUE == isBoostPumpInstalled() ) { - setBoostPumpTargetPressure( PERMEATE_FLUSH_BOOST_PUMP_TGT_PSI ); + setBoostPumpTargetPressure( PERMEATE_FLUSH_BOOST_PUMP_TGT_PSI, TRUE ); } //TODO update target macro after changing it to 750 + rinse pump rate setROPumpTargetFlowRateMLPM( PERMEATE_FLUSH_RO_PUMP_TGT_ML, TRUE );