Index: firmware/App/Controllers/DryBiCart.c =================================================================== diff -u -r3aa700c036437377bca1de55bc01307705abf0a5 -r4e35963753273d2481691fceb799ca8d5819309a --- firmware/App/Controllers/DryBiCart.c (.../DryBiCart.c) (revision 3aa700c036437377bca1de55bc01307705abf0a5) +++ firmware/App/Controllers/DryBiCart.c (.../DryBiCart.c) (revision 4e35963753273d2481691fceb799ca8d5819309a) @@ -52,8 +52,8 @@ #define DRY_BICART_FILL_COMPLETE_TIME_MS ( 1 * MS_PER_SECOND ) ///< Wait time to reset the request flag after fill complete #define DRY_BICART_WCID2_FILL_COMPLETE_PRESSURE_PSI ( 10.0F + WCDI2_PRESSURE_OFFSET_PSI ) ///< Maximum pressure reached to indicate the dry bicart fill being completed for WCID2 #define DRY_BICART_WCID1_FILL_COMPLETE_PRESSURE_PSI ( 10.0F + WCID1_PRESSURE_OFFSET_PSI ) ///< Maximum pressure reached to indicate the dry bicart fill being completed for WCID1 -#define GET_DRY_BICART_FILL_COMPLETE_PRESSURE_PSI (getTestConfigStatus( TEST_CONFIG_DD_ENABLE_WCID_1 ) \ - != TRUE ? DRY_BICART_WCID2_FILL_COMPLETE_PRESSURE_PSI : DRY_BICART_WCID1_FILL_COMPLETE_PRESSURE_PSI ) +#define GET_FILL_COMPLETE_PRESSURE_PSI (getTestConfigStatus( TEST_CONFIG_DD_ENABLE_WCID_1 ) != TRUE ? \ + DRY_BICART_WCID2_FILL_COMPLETE_PRESSURE_PSI : DRY_BICART_WCID1_FILL_COMPLETE_PRESSURE_PSI ) ///< Get fill complete pressure based on the WCID configuration #define DRY_BICART_FILL_INITIATE_PRESSURE_PSI 1.5F ///< Minimum pressure required to initiate the dry bicart fill process. #define DRY_BICART_FILL_COMPLETE_SUPPLY_PRESSURE_PSI 10.0F ///< Maximum pressure allowed at bicart fill during supply process/state #define DRY_BICART_FILL_INITIATE_SUPPLY_PRESSURE_PSI 3.0F ///< Minimum pressure required to initiate the dry bicart fill during supply process/state @@ -760,7 +760,7 @@ { DRY_BICART_FILL_EXEC_STATE_T state = DRY_BICART_FILL_WATER_END_STATE; F32 d66Pressure = getFilteredPressure( D66_PRES ); - F32 fillCompletePressure = GET_DRY_BICART_FILL_COMPLETE_PRESSURE_PSI; + F32 fillCompletePressure = GET_FILL_COMPLETE_PRESSURE_PSI; // Close dry bicart inlet water if D66 pressure is 17 PSI if ( d66Pressure >= fillCompletePressure ) @@ -1023,7 +1023,7 @@ { BICARB_CHAMBER_FILL_EXEC_STATE_T state = BICARB_CARTRIDGE_FILL_WATER_END_STATE; F32 d66Pressure = getFilteredPressure( D66_PRES ); - F32 fillCompletePressure = GET_DRY_BICART_FILL_COMPLETE_PRESSURE_PSI; + F32 fillCompletePressure = GET_FILL_COMPLETE_PRESSURE_PSI; // check D66 pressure greater than or equal to 17 PSI if ( d66Pressure >= fillCompletePressure )