Index: firmware/App/Controllers/Heaters.c =================================================================== diff -u -r09583a9e0a51bb47dd04c825cd706f5a3774bded -r739fdfd941e5d4dc52ca3b9916aabb8ef2d2ad45 --- firmware/App/Controllers/Heaters.c (.../Heaters.c) (revision 09583a9e0a51bb47dd04c825cd706f5a3774bded) +++ firmware/App/Controllers/Heaters.c (.../Heaters.c) (revision 739fdfd941e5d4dc52ca3b9916aabb8ef2d2ad45) @@ -52,7 +52,7 @@ #define HEATERS_DUTY_CYCLE_CONVERSION_FACTOR 100.0F ///< Heaters duty cycle 0: OFF, 100: 100% duty cycle. #define HEATERS_ZERO_EFFICIENCY 0.0F ///< Zero heater efficiency #define HEATER_CNTL_TRANSFER_DELTA_TEMP_C 0.50F ///< AC heater delta temperature to transfer control from open to close loop -#define MAX_ADJ_DELTA_TEMP_C 2.0F ///< Maximum adjusted delta temperature to add/remove from calculated target temperature +#define MAX_ADJ_DELTA_TEMP_C 10.0F ///< Maximum adjusted delta temperature to add/remove from calculated target temperature #define D5_HEAT_TX_INIT_FEED_FORWARD 0.0F ///< Initial Feed forward term for heater control //#define D5_HEAT_TX_P_COEFFICIENT 0.050F ///< P Term for AC primary heater control during treatment mode. @@ -82,7 +82,7 @@ #define D5_HEAT_CONTROL_INTERVAL_COUNT ( D5_HEAT_CONTROL_INTERVAL_MS / TASK_GENERAL_INTERVAL ) ///< Primary heater control interval count. #define D45_HEAT_CONTROL_INTERVAL_MS ( 1 * MS_PER_SECOND ) ///< Trimmer heater control interval in milli seconds #define D45_HEAT_CONTROL_INTERVAL_COUNT ( D45_HEAT_CONTROL_INTERVAL_MS / TASK_GENERAL_INTERVAL ) ///< Trimmer heater control interval count. -#define D5_TARGET_TEMP_ADJUST_INTERVAL_MS ( 10 * SEC_PER_MIN * MS_PER_SECOND / TASK_GENERAL_INTERVAL ) ///< Adjust primary target temperature +#define D5_TARGET_TEMP_ADJUST_INTERVAL_MS ( 2 * SEC_PER_MIN * MS_PER_SECOND / TASK_GENERAL_INTERVAL ) ///< Adjust primary target temperature #define PRIMARY_HEATER_MAX_PWR_WATTS 1400.0F ///< AC Primary Heater Max Power consumeption in Watts #define TX_PRIMARY_HEATER_MAX_PWR_WATTS 700.0F ///< Estimated power to be supplied to the primary heater during treatement mode #define HEAT_PRIMARY_HEATER_MAX_PWR_WATTS 980.0F ///< Estimated power to be supplied to the primary heater during heat disinfect mode