Index: firmware/App/Modes/FPModes/FlushFilter.c =================================================================== diff -u -rfd21e08ba076054488aa112641e0db4191ee0b35 -r7594294ed040b16277a89be6161d7ab9321e4b08 --- firmware/App/Modes/FPModes/FlushFilter.c (.../FlushFilter.c) (revision fd21e08ba076054488aa112641e0db4191ee0b35) +++ firmware/App/Modes/FPModes/FlushFilter.c (.../FlushFilter.c) (revision 7594294ed040b16277a89be6161d7ab9321e4b08) @@ -34,7 +34,6 @@ #define FILTER_FLUSH_MAX_TIMEOUT ( 600 * MS_PER_SECOND ) ///< Max override timeout for 10 minutes #define FILTER_FLUSH_DATA_PUBLISH_INTERVAL ( MS_PER_SECOND / TASK_GENERAL_INTERVAL ) ///< Interval (ms/task time) at which the gen water mode data published. #define FILTER_FLUSH_TIMEOUT ( 30 * MS_PER_SECOND ) ///< Filter flush timer (in ms) -#define FILTER_HEALTH_PRESSURE_DIFF 15 ///< Filter flush pressure difference threshold for alarm // ********** private data ********** @@ -136,19 +135,8 @@ if( TRUE == didTimeout( filterFlushTimer, getFilterFlushTimeout() ) ) { - pressureDif = fabs( getFilteredPressure(M3_PRES) - getFilteredPressure(P8_PRES) ); - isPressureOutOfRange = ( pressureDif > FILTER_HEALTH_PRESSURE_DIFF ? TRUE : FALSE ); - - if( TRUE == isPressureOutOfRange ) - { - SET_ALARM_WITH_2_U32_DATA( ALARM_ID_FP_FILTER_HEALTH_PRESSURE_OUT_OF_RANGE, pressureDif, FILTER_HEALTH_PRESSURE_DIFF ); - state = FILTER_FLUSH_PAUSED; - } - else - { - isFlushComplete = TRUE; - state = FILTER_FLUSH_PAUSED; - } + isFlushComplete = TRUE; + state = FILTER_FLUSH_PAUSED; } return state;