Index: firmware/App/Controllers/ConcentratePumps.c =================================================================== diff -u -r7d4711edd7b40cd3e29f43e766f79a8a09586fe9 -rc1d5811ec6c4c0005870ef1fb955eb5b6b2ec27c --- firmware/App/Controllers/ConcentratePumps.c (.../ConcentratePumps.c) (revision 7d4711edd7b40cd3e29f43e766f79a8a09586fe9) +++ firmware/App/Controllers/ConcentratePumps.c (.../ConcentratePumps.c) (revision c1d5811ec6c4c0005870ef1fb955eb5b6b2ec27c) @@ -65,7 +65,6 @@ #define NUMBER_OF_ACID_AND_BICARB_NV_DATA_TO_CHECK 1 ///< Number of acid and bicarb non-volatile data to check. #define DATA_PUBLISH_COUNTER_START_COUNT 0 ///< Data publish counter start count. -#define CONENTREATE_PUMP_PARK_FAULT_TIMEOUT_MS ( 1 * MS_PER_SECOND ) ///< Concentrate pump park fault timeout in milliseconds. #define CONCENTRATE_PUMP_FAULT_PERSISTENCE_PERIOD 500 ///< Concentrate pump fault persistence period in milliseconds. #define CONCENTRATE_PUMP_TRANS_TO_RAMP_SPEED_THRESHOLD_MLPM 5.0F ///< Concentrate pump transition to ramp to target speed threshold in mL/min. @@ -179,8 +178,6 @@ initPersistentAlarm( ALARM_ID_DG_CP1_SPEED_CONTROL_ERROR, 0, CONCENTRATE_PUMP_SPEED_OUT_OF_RANGE_TIMEOUT_MS ); initPersistentAlarm( ALARM_ID_DG_CP2_SPEED_CONTROL_ERROR, 0, CONCENTRATE_PUMP_SPEED_OUT_OF_RANGE_TIMEOUT_MS ); initPersistentAlarm( ALARM_ID_DG_CONC_PUMP_HALL_SENSOR_OUT_OF_RANGE, CONCENTRATE_PUMP_HALL_SENSORS_OUT_OF_RANGE_TIME_MS, CONCENTRATE_PUMP_HALL_SENSORS_OUT_OF_RANGE_TIME_MS ); - initPersistentAlarm( ALARM_ID_DG_ACID_CONCENTRATE_PUMP_PARK_FAULT, CONENTREATE_PUMP_PARK_FAULT_TIMEOUT_MS, CONENTREATE_PUMP_PARK_FAULT_TIMEOUT_MS ); - initPersistentAlarm( ALARM_ID_DG_BICARB_CONCENTRATE_PUMP_PARK_FAULT, CONENTREATE_PUMP_PARK_FAULT_TIMEOUT_MS, CONENTREATE_PUMP_PARK_FAULT_TIMEOUT_MS ); initPersistentAlarm( ALARM_ID_DG_CONCENTRATE_PUMP_FAULT, CONCENTRATE_PUMP_FAULT_PERSISTENCE_PERIOD, CONCENTRATE_PUMP_FAULT_PERSISTENCE_PERIOD ); } @@ -250,17 +247,6 @@ monitorPumpSpeed( CONCENTRATEPUMPS_CP2_BICARB, ALARM_ID_DG_CP2_SPEED_CONTROL_ERROR ); } -#ifndef _RELEASE_ - if ( getSoftwareConfigStatus( SW_CONFIG_DISABLE_CONCENTRATE_PUMPS_PARK ) != SW_CONFIG_ENABLE_VALUE ) -#endif - { - BOOL isAcidPumpParked = getConcPumpParkIsFaulted( CONCENTRATEPUMPS_CP1_ACID ); - BOOL isBicarbPumpParked = getConcPumpParkIsFaulted( CONCENTRATEPUMPS_CP2_BICARB ); - - checkPersistentAlarm( ALARM_ID_DG_ACID_CONCENTRATE_PUMP_PARK_FAULT, isAcidPumpParked, isAcidPumpParked, CONENTREATE_PUMP_PARK_FAULT_TIMEOUT_MS ); - checkPersistentAlarm( ALARM_ID_DG_BICARB_CONCENTRATE_PUMP_PARK_FAULT, isBicarbPumpParked, isBicarbPumpParked, CONENTREATE_PUMP_PARK_FAULT_TIMEOUT_MS ); - } - checkPersistentAlarm( ALARM_ID_DG_CONCENTRATE_PUMP_FAULT, isConcPumpFault, fpgaConcPumpsFault, CONCENTRATE_PUMP_FAULT_PERSISTENCE_PERIOD ); if ( ++concentratePumpMonitorTimerCounter >= getU32OverrideValue( &concentratePumpDataPublishInterval ) )