Index: firmware/App/Controllers/ROPump.c =================================================================== diff -u -r5652568f680408e60fe5fb84eee926e8804c07d7 -rbc79ea1fc44ed327da7efcca54af9db15b8c88cd --- firmware/App/Controllers/ROPump.c (.../ROPump.c) (revision 5652568f680408e60fe5fb84eee926e8804c07d7) +++ firmware/App/Controllers/ROPump.c (.../ROPump.c) (revision bc79ea1fc44ed327da7efcca54af9db15b8c88cd) @@ -184,15 +184,15 @@ MIN_RO_PUMP_DUTY_CYCLE, MAX_RO_PUMP_DUTY_CYCLE ); // Initialize the persistent alarm for flow out of upper and lower range - initPersistentAlarm( ALARM_ID_FLOW_RATE_OUT_OF_UPPER_RANGE, FLOW_OUT_OF_RANGE_TIME_OUT_MS, FLOW_OUT_OF_RANGE_TIME_OUT_MS ); - initPersistentAlarm( ALARM_ID_FLOW_RATE_OUT_OF_LOWER_RANGE, FLOW_OUT_OF_RANGE_TIME_OUT_MS, FLOW_OUT_OF_RANGE_TIME_OUT_MS ); + initPersistentAlarm( ALARM_ID_DG_FLOW_RATE_OUT_OF_UPPER_RANGE, FLOW_OUT_OF_RANGE_TIME_OUT_MS, FLOW_OUT_OF_RANGE_TIME_OUT_MS ); + initPersistentAlarm( ALARM_ID_DG_FLOW_RATE_OUT_OF_LOWER_RANGE, FLOW_OUT_OF_RANGE_TIME_OUT_MS, FLOW_OUT_OF_RANGE_TIME_OUT_MS ); // Initialize the persistent alarm for max allowed pressure out of range - initPersistentAlarm( ALARM_ID_RO_PUMP_PRESSURE_OUT_OF_RANGE, MAX_PRESSURE_OUT_OF_RANGE_PERSISTENT_INTERVAL, + initPersistentAlarm( ALARM_ID_DG_RO_PUMP_PRESSURE_OUT_OF_RANGE, MAX_PRESSURE_OUT_OF_RANGE_PERSISTENT_INTERVAL, MAX_PRESSURE_OUT_OF_RANGE_PERSISTENT_INTERVAL ); // Initialize the persistent alarm for not turning off the pump - initPersistentAlarm( ALARM_ID_RO_PUMP_DUTY_CYCLE_OUT_OF_RANGE, SAFETY_SHUTDOWN_TIMEOUT, SAFETY_SHUTDOWN_TIMEOUT ); + initPersistentAlarm( ALARM_ID_DG_RO_PUMP_DUTY_CYCLE_OUT_OF_RANGE, SAFETY_SHUTDOWN_TIMEOUT, SAFETY_SHUTDOWN_TIMEOUT ); // Initialize the variables roControlTimerCounter = 0; @@ -388,7 +388,7 @@ BOOL isPressureMax = ( actualPressure >= MAX_ALLOWED_MEASURED_PRESSURE_PSI ? TRUE : FALSE ); BOOL isDutyCylceOutOfRange = FALSE; - checkPersistentAlarm( ALARM_ID_RO_PUMP_PRESSURE_OUT_OF_RANGE, isPressureMax, actualPressure, MAX_ALLOWED_MEASURED_PRESSURE_PSI ); + checkPersistentAlarm( ALARM_ID_DG_RO_PUMP_PRESSURE_OUT_OF_RANGE, isPressureMax, actualPressure, MAX_ALLOWED_MEASURED_PRESSURE_PSI ); if ( ( getMeasuredFlowRateLPM( RO_FLOW_SENSOR ) > NEARLY_ZERO ) && ( VALVE_STATE_CLOSED == getValveStateName( VBF ) ) ) { @@ -418,13 +418,13 @@ BOOL isFlowOutOfUpperRange = ( isFlowOutOfRange && ( currentFlow > targetFlow ) ? TRUE : FALSE ); BOOL isFlowOutOfLowerRange = ( isFlowOutOfRange && ( currentFlow < targetFlow ) ? TRUE : FALSE ); - checkPersistentAlarm( ALARM_ID_FLOW_RATE_OUT_OF_UPPER_RANGE, isFlowOutOfUpperRange, currentFlow, targetFlow ); - checkPersistentAlarm( ALARM_ID_FLOW_RATE_OUT_OF_LOWER_RANGE, isFlowOutOfLowerRange, currentFlow, targetFlow ); + checkPersistentAlarm( ALARM_ID_DG_FLOW_RATE_OUT_OF_UPPER_RANGE, isFlowOutOfUpperRange, currentFlow, targetFlow ); + checkPersistentAlarm( ALARM_ID_DG_FLOW_RATE_OUT_OF_LOWER_RANGE, isFlowOutOfLowerRange, currentFlow, targetFlow ); } else { - checkPersistentAlarm( ALARM_ID_FLOW_RATE_OUT_OF_UPPER_RANGE, FALSE, 0.0F, 0.0F ); - checkPersistentAlarm( ALARM_ID_FLOW_RATE_OUT_OF_LOWER_RANGE, FALSE, 0.0F, 0.0F ); + checkPersistentAlarm( ALARM_ID_DG_FLOW_RATE_OUT_OF_UPPER_RANGE, FALSE, 0.0F, 0.0F ); + checkPersistentAlarm( ALARM_ID_DG_FLOW_RATE_OUT_OF_LOWER_RANGE, FALSE, 0.0F, 0.0F ); } #ifndef _RELEASE_ @@ -436,10 +436,10 @@ roPumpFeedbackDutyCyclePct.data = 1.0F - ( roFeedbackVoltage / ROP_FEEDBACK_0_PCT_DUTY_CYCLE_VOLTAGE ); isDutyCylceOutOfRange = ( fabs( getROFeedbackDutyCycle() - roPumpDutyCyclePctSet ) > ROP_DUTY_CYCLE_OUT_OF_RANGE_TOLERANCE ? TRUE : FALSE ); - checkPersistentAlarm( ALARM_ID_RO_PUMP_DUTY_CYCLE_OUT_OF_RANGE, isDutyCylceOutOfRange, getROFeedbackDutyCycle(), roPumpDutyCyclePctSet ); + checkPersistentAlarm( ALARM_ID_DG_RO_PUMP_DUTY_CYCLE_OUT_OF_RANGE, isDutyCylceOutOfRange, getROFeedbackDutyCycle(), roPumpDutyCyclePctSet ); // Check if it the alarm has timed out and if the pump is supposed to be off but it is still on, activate the safety shutdown - if ( ( TRUE == isAlarmActive( ALARM_ID_RO_PUMP_DUTY_CYCLE_OUT_OF_RANGE ) ) && ( FALSE == isROPumpOn ) ) + if ( ( TRUE == isAlarmActive( ALARM_ID_DG_RO_PUMP_DUTY_CYCLE_OUT_OF_RANGE ) ) && ( FALSE == isROPumpOn ) ) { activateSafetyShutdown(); }