Index: firmware/App/DGCommon.h =================================================================== diff -u -r2f13a0f53d8081b6be32a7aae0d4c287ac31e2f3 -r23fd3843b6e50ff90b4db987be553c823bfd6597 --- firmware/App/DGCommon.h (.../DGCommon.h) (revision 2f13a0f53d8081b6be32a7aae0d4c287ac31e2f3) +++ firmware/App/DGCommon.h (.../DGCommon.h) (revision 23fd3843b6e50ff90b4db987be553c823bfd6597) @@ -8,7 +8,7 @@ * @file DGCommon.h * * @author (last) Dara Navaei -* @date (last) 02-Mar-2022 +* @date (last) 31-Mar-2022 * * @author (original) Sean * @date (original) 27-Feb-2020 @@ -32,37 +32,39 @@ #ifndef _RELEASE_ #ifndef _VECTORCAST_ // TODO: Removed debug build flags when release build is ready -// #define BOARD_WITH_NO_HARDWARE 1 -// #define TASK_TIMING_OUTPUT_ENABLED 1 // re-purposes drain pump enable pin for task timing -// #define DISABLE_HEATERS_AND_TEMPS 1 - #define DISABLE_ACCELS 1 -// #define SKIP_POST 1 - #define SKIP_CAL_CHECK 1 -// #define ENABLE_DIP_SWITCHES 1 -// #define EMC_TEST_BUILD 1 - #define ALARMS_DEBUG 1 -// #define HEATERS_DEBUG 1 -// #define PRESSURES_DEBUG 1 - // #define IGNORE_DRAIN_PUMP_MONITOR 1 - #define IGNORE_HEATERS_MONITOR 1 - #define IGNORE_RO_PUMP_MONITOR 1 - #define DISABLE_RO_RATIO_CHECK 1 - #define DISABLE_COND_SENSOR_CHECK 1 // Disabled for Tom -// #define DISABLE_WATER_QUALITY_CHECK 1 // Disabled for Tom - #define DISABLE_RTC_CONFIG 1 - #define THD_USING_TRO_CONNECTOR 1 - #define DISABLE_FLOW_CHECK_IN_FILL 1 - #define IGNORE_CONC_PUMP_IN_HEAT_DISINFECT 1 -// #define NEW_FMD_FLOW_SENSOR 1 +// #define BOARD_WITH_NO_HARDWARE 1 // Build switch +// #define TASK_TIMING_OUTPUT_ENABLED 1 // Build switch // re-purposes drain pump enable pin for task timing +// #define DISABLE_HEATERS_AND_TEMPS 1 // Implement +// #define DISABLE_ACCELS 1 // Implement +// #define SKIP_POST 1 // Not needed + #define SKIP_CAL_CHECK 1 // Implement +// #define ENABLE_DIP_SWITCHES 1 // Not needed +// #define EMC_TEST_BUILD 1 // Build switch + #define ALARMS_DEBUG 1 // Not needed +// #define HEATERS_DEBUG 1 // Not needed +// #define PRESSURES_DEBUG 1 // Not needed + // #define IGNORE_DRAIN_PUMP_MONITOR 1 // Build switch + #define IGNORE_HEATERS_MONITOR 1 // Build switch + #define IGNORE_RO_PUMP_MONITOR 1 // Build switch + #define DISABLE_RO_RATIO_CHECK 1 // Implement + #define DISABLE_COND_SENSOR_CHECK 1 // Disabled for Tom // Implement + #define DISABLE_WATER_QUALITY_CHECK 1 // Disabled for Tom // Implement + #define DISABLE_RTC_CONFIG 1 // Not needed + #define THD_USING_TRO_CONNECTOR 1 // Build switch + #define DISABLE_FLOW_CHECK_IN_FILL 1 // Implement + #define IGNORE_CONC_PUMP_IN_HEAT_DISINFECT 1 // Not needed +// #define NEW_FMD_FLOW_SENSOR 1 // Not needed + #define DISABLE_HEATERS_EFFICIENCY 1 #define DISABLE_COND_STATUS_CHECK 1 /// Build switch #define DISABLE_DISINFECT_CONDUCTIVITY 1 // Implement // #define DISABLE_CONC_PUMPS 1 // #define DISABLE_CAP_SWITCHES 1 // Implement // #define DISABLE_UV_REACTORS 1 #define DISABLE_ACID_BICARB_ALARMS 1 // Implement + #define DISABLE_EMPTY_BOTTLES_ALARMS 1 // Implement - #define DISABLE_PRIME_CONCENT_LINES 1 + #define DISABLE_BICARB_CONDUCTIVITY_TEST 1 #define DISABLE_ACID_CONDUCTIVITY_TEST 1 // Turn these flags on to disable dialysate mixing