Index: firmware/App/Services/SystemComm.c =================================================================== diff -u -rd838fbaa8507b883fa112e69137e86fc9fb2cb6f -r2a88e9acf15658fb4ed6515c486a230cb4490452 --- firmware/App/Services/SystemComm.c (.../SystemComm.c) (revision d838fbaa8507b883fa112e69137e86fc9fb2cb6f) +++ firmware/App/Services/SystemComm.c (.../SystemComm.c) (revision 2a88e9acf15658fb4ed6515c486a230cb4490452) @@ -1,20 +1,19 @@ -/************************************************************************** - * - * Copyright (c) 2019-2020 Diality Inc. - All Rights Reserved. - * - * THIS CODE MAY NOT BE COPIED OR REPRODUCED IN ANY FORM, IN PART OR IN - * WHOLE, WITHOUT THE EXPLICIT PERMISSION OF THE COPYRIGHT OWNER. - * - * @file SystemComm.c - * - * @date 08-Oct-2019 - * @author S. Nash - * - * @brief SystemComm service module. Provides system message communication \n - * functionality. Messages can be queued for transmission. Incoming messages \n - * are processed. - * - **************************************************************************/ +/************************************************************************** +* +* Copyright (c) 2019-2020 Diality Inc. - All Rights Reserved. +* +* THIS CODE MAY NOT BE COPIED OR REPRODUCED IN ANY FORM, IN PART OR IN +* WHOLE, WITHOUT THE EXPLICIT PERMISSION OF THE COPYRIGHT OWNER. +* +* @file SystemComm.c +* +* @author (last) Quang Nguyen +* @date (last) 23-Jul-2020 +* +* @author (original) Dara Navaei +* @date (original) 05-Nov-2019 +* +***************************************************************************/ #include // for memcpy() @@ -533,12 +532,12 @@ { signalCANXmitsCompleted(); // TODO - shouldn't get here, but let's see if we do - SET_ALARM_WITH_1_U32_DATA( ALARM_ID_SOFTWARE_FAULT, (U32)mBox ) + SET_ALARM_WITH_1_U32_DATA( ALARM_ID_DG_SOFTWARE_FAULT, (U32)mBox ) } } else { // TODO - shouldn't get here - just testing - set first data to new s/w fault enum later - SET_ALARM_WITH_2_U32_DATA( ALARM_ID_SOFTWARE_FAULT, (U32)buffer, (U32)dataSize ) + SET_ALARM_WITH_2_U32_DATA( ALARM_ID_DG_SOFTWARE_FAULT, (U32)buffer, (U32)dataSize ) } } @@ -1070,7 +1069,7 @@ handleTestROPumpDataBroadcastIntervalOverrideRequest( message ); break; - case MSG_ID_DRAIN_PUMP_SET_PT_OVERRIDE: + case MSG_ID_DRAIN_PUMP_SET_RPM_OVERRIDE: handleTestDrainPumpSetPointOverrideRequest( message ); break; @@ -1088,6 +1087,7 @@ case MSG_ID_DG_SAFETY_SHUTDOWN_OVERRIDE: handleTestDGSafetyShutdownOverrideRequest( message ); + break; case MSG_ID_TEMPERATURE_SENSORS_VALUE_OVERRIDE: handleTestTemperatureSensorsOverrideRequest ( message ); @@ -1099,8 +1099,16 @@ case MSG_ID_HEATERS_PUBLISH_INTERVAL_ORVERRIDE: handleTestHeatersDataPublishOverrideRequest ( message ); - break; + break; + case MSG_ID_CONDUCTIVITY_OVERRIDE: + handleTestSetConductivityOverrideRequest ( message ); + break; + + case MSG_ID_CONDUCTIVITY_PUBLISH_INTERVAL_OVERRIDE: + handleTestSetConductivityDataPublishIntervalOverrideRequest ( message ); + break; + default: // TODO - unrecognized message ID received - ignore break;