Index: firmware/App/Controllers/LoadCell.c =================================================================== diff -u -r95eefee71702fbf031025dc35ebaf553dfb050b7 -r1af5c9d200064f18e2727e896f74308e683492a7 --- firmware/App/Controllers/LoadCell.c (.../LoadCell.c) (revision 95eefee71702fbf031025dc35ebaf553dfb050b7) +++ firmware/App/Controllers/LoadCell.c (.../LoadCell.c) (revision 1af5c9d200064f18e2727e896f74308e683492a7) @@ -183,7 +183,7 @@ if ( TRUE == isNewCalibrationRecordAvailable() ) { getNVRecord2Driver( GET_CAL_LOAD_CELL_SENSORS, (U08*)&loadCellsCalRecord, sizeof( DG_LOAD_CELLS_CAL_RECORD_T ), - NUM_OF_CAL_DATA_LOAD_CELLS, ALARM_ID_DG_LOAD_CELLS_INVALID_CALIBRATION ); + NUM_OF_CAL_DATA_LOAD_CELLS, ALARM_ID_DG_LOAD_CELLS_INVALID_CAL_RECORD ); // Zero the current tare values when new calibration data is available loadcells[ LOAD_CELL_RESERVOIR_1_PRIMARY ].autoCalOffset = 0.0; @@ -275,7 +275,7 @@ SELF_TEST_STATUS_T result = SELF_TEST_STATUS_IN_PROGRESS; BOOL calStatus = getNVRecord2Driver( GET_CAL_LOAD_CELL_SENSORS, (U08*)&loadCellsCalRecord, sizeof( DG_LOAD_CELLS_CAL_RECORD_T ), - NUM_OF_CAL_DATA_LOAD_CELLS, ALARM_ID_DG_LOAD_CELLS_INVALID_CALIBRATION ); + NUM_OF_CAL_DATA_LOAD_CELLS, ALARM_ID_DG_LOAD_CELLS_INVALID_CAL_RECORD ); if ( TRUE == calStatus ) { Index: firmware/App/Controllers/Pressures.c =================================================================== diff -u -r95eefee71702fbf031025dc35ebaf553dfb050b7 -r1af5c9d200064f18e2727e896f74308e683492a7 --- firmware/App/Controllers/Pressures.c (.../Pressures.c) (revision 95eefee71702fbf031025dc35ebaf553dfb050b7) +++ firmware/App/Controllers/Pressures.c (.../Pressures.c) (revision 1af5c9d200064f18e2727e896f74308e683492a7) @@ -117,8 +117,8 @@ measuredPressureReadingsSum[ i ] = 0; } - pressuresState = PRESSURE_INIT_STATE; - pressuresSelfTestState = PRESSURE_SELF_TEST_STATE_START; + pressuresState = PRESSURE_INIT_STATE; + pressuresSelfTestState = PRESSURE_SELF_TEST_STATE_START; pressuresDataPublicationTimerCounter = DATA_PUBLISH_COUNTER_START_COUNT; initPersistentAlarm( ALARM_ID_INLET_WATER_PRESSURE_IN_LOW_RANGE, INLET_WATER_PRESSURE_PERSISTENCE_PERIOD, INLET_WATER_PRESSURE_PERSISTENCE_PERIOD ); @@ -389,7 +389,7 @@ for ( i = 0; i < PRESSURE_SENSORS_ADC_CHECK_ARRAY_LEN; i++ ) { - sensorADC = sensorsADC[ i ]; + sensorADC = sensorsADC[ i ]; if ( ( 0 == sensorADC ) || ( sensorADC >= INT_ADC_FULL_SCALE_BITS ) ) { Index: firmware/App/DGCommon.h =================================================================== diff -u -r95eefee71702fbf031025dc35ebaf553dfb050b7 -r1af5c9d200064f18e2727e896f74308e683492a7 --- firmware/App/DGCommon.h (.../DGCommon.h) (revision 95eefee71702fbf031025dc35ebaf553dfb050b7) +++ firmware/App/DGCommon.h (.../DGCommon.h) (revision 1af5c9d200064f18e2727e896f74308e683492a7) @@ -44,7 +44,7 @@ // #define HEATERS_DEBUG 1 // Not needed // #define PRESSURES_DEBUG 1 // Not needed // #define IGNORE_DRAIN_PUMP_MONITOR 1 // Build switch - // #define IGNORE_HEATERS_MONITOR 1 // Build switch + #define IGNORE_HEATERS_MONITOR 1 // Build switch #define IGNORE_RO_PUMP_MONITOR 1 // Build switch #define DISABLE_RO_RATIO_CHECK 1 // Implement // #define DISABLE_COND_SENSOR_CHECK 1 // Disabled for Tom // Implement Index: firmware/App/Services/SystemComm.c =================================================================== diff -u -r66cc826068b54bc436cde0fae70a05ba6c1ac974 -r1af5c9d200064f18e2727e896f74308e683492a7 --- firmware/App/Services/SystemComm.c (.../SystemComm.c) (revision 66cc826068b54bc436cde0fae70a05ba6c1ac974) +++ firmware/App/Services/SystemComm.c (.../SystemComm.c) (revision 1af5c9d200064f18e2727e896f74308e683492a7) @@ -672,7 +672,7 @@ { if ( TRUE == incTimeWindowedCount( TIME_WINDOWED_COUNT_BAD_MSG_CRC ) ) { - SET_ALARM_WITH_1_U32_DATA( ALARM_ID_COMM_TOO_MANY_BAD_CRCS, 2 ); // 2 for DG + SET_ALARM_WITH_1_U32_DATA( ALARM_ID_DG_COMM_TOO_MANY_BAD_CRCS, 2 ); // 2 for DG } } @@ -781,7 +781,7 @@ memcpy( &msgID, &pendingAckList[ i ].msg[ sizeof( U08 ) + sizeof( U16) ], sizeof( U16 ) ); #ifndef DISABLE_ACK_ALARM - SET_ALARM_WITH_1_U32_DATA( ALARM_ID_CAN_MESSAGE_NOT_ACKED, (U32)msgID ); + SET_ALARM_WITH_1_U32_DATA( ALARM_ID_DG_CAN_MESSAGE_NOT_ACKED, (U32)msgID ); #endif pendingAckList[ i ].used = FALSE; // take pending message off of list } Index: firmware/App/Services/WatchdogMgmt.c =================================================================== diff -u -re0cdf49eb0f54239e5d765282e0952cea7ded1bd -r1af5c9d200064f18e2727e896f74308e683492a7 --- firmware/App/Services/WatchdogMgmt.c (.../WatchdogMgmt.c) (revision e0cdf49eb0f54239e5d765282e0952cea7ded1bd) +++ firmware/App/Services/WatchdogMgmt.c (.../WatchdogMgmt.c) (revision 1af5c9d200064f18e2727e896f74308e683492a7) @@ -121,7 +121,7 @@ ( getCurrentOperationMode() != DG_MODE_INIT ) ) { #ifndef DEBUG_ENABLED - activateAlarmNoData( ALARM_ID_WATCHDOG_EXPIRED ); + activateAlarmNoData( ALARM_ID_DG_WATCHDOG_EXPIRED ); #endif } } @@ -191,7 +191,7 @@ case WATCHDOG_SELF_TEST_STATE_RECOVER: if ( TRUE == didTimeout( watchdogSelfTestTimerCount, WATCHDOG_RECOVERY_TIME_MS ) ) { - if ( getCPLDWatchdogExpired() == PIN_SIGNAL_HIGH ) + if ( PIN_SIGNAL_HIGH == getCPLDWatchdogExpired() ) { F32 v24 = getIntADCVoltageConverted( INT_ADC_PRIMARY_HEATER_24_VOLTS );