Index: firmware/App/Modes/ModeFill.c =================================================================== diff -u -r4ca9ae0989215af5b543637dc4b435f8b38480d2 -r77cf960846ef93d74fec68572fa596bf1f24bdc3 --- firmware/App/Modes/ModeFill.c (.../ModeFill.c) (revision 4ca9ae0989215af5b543637dc4b435f8b38480d2) +++ firmware/App/Modes/ModeFill.c (.../ModeFill.c) (revision 77cf960846ef93d74fec68572fa596bf1f24bdc3) @@ -627,7 +627,7 @@ { result = DG_FILL_MODE_STATE_PRIME_CONCENTRATE_LINES; - if ( TRUE == getTestConfigStatus( TEST_CONFIG_MIX_WITH_WATER ) ) + if ( TRUE == getTestConfigStatus( TEST_CONFIG_EXPEDITE_PRE_TREATMENT ) ) { // If expedite pre-treatment flag is enabled, do not do the initial fill result = DG_FILL_MODE_STATE_PRODUCE_DIALYSATE; Index: firmware/App/Modes/ModeHeatDisinfect.c =================================================================== diff -u -r4ca9ae0989215af5b543637dc4b435f8b38480d2 -r77cf960846ef93d74fec68572fa596bf1f24bdc3 --- firmware/App/Modes/ModeHeatDisinfect.c (.../ModeHeatDisinfect.c) (revision 4ca9ae0989215af5b543637dc4b435f8b38480d2) +++ firmware/App/Modes/ModeHeatDisinfect.c (.../ModeHeatDisinfect.c) (revision 77cf960846ef93d74fec68572fa596bf1f24bdc3) @@ -780,8 +780,8 @@ rsrvr2Status = DG_RESERVOIR_BELOW_TARGET; // Done with flushing the concentrate pumps line - requestConcentratePumpOff( CONCENTRATEPUMPS_CP1_ACID, PARK_CONC_PUMPS ); // NO_PARK_CONC_PUMPS ); - requestConcentratePumpOff( CONCENTRATEPUMPS_CP2_BICARB, PARK_CONC_PUMPS ); // NO_PARK_CONC_PUMPS ); + requestConcentratePumpOff( CONCENTRATEPUMPS_CP1_ACID, NO_PARK_CONC_PUMPS ); + requestConcentratePumpOff( CONCENTRATEPUMPS_CP2_BICARB, NO_PARK_CONC_PUMPS ); setValveState( VPO, VALVE_STATE_FILL_C_TO_NC ); setValveState( VRF, VALVE_STATE_R1_C_TO_NC ); @@ -1192,8 +1192,8 @@ break; case HEAT_DISINFECT_COMPLETE: - requestConcentratePumpOff( CONCENTRATEPUMPS_CP1_ACID, PARK_CONC_PUMPS ); //NO_PARK_CONC_PUMPS ); - requestConcentratePumpOff( CONCENTRATEPUMPS_CP2_BICARB, PARK_CONC_PUMPS ); // NO_PARK_CONC_PUMPS ); + requestConcentratePumpOff( CONCENTRATEPUMPS_CP1_ACID, NO_PARK_CONC_PUMPS ); + requestConcentratePumpOff( CONCENTRATEPUMPS_CP2_BICARB, NO_PARK_CONC_PUMPS ); // Although there is fluid in both reservoirs, but they are set to empty // to begin the transition of hot water from R1 to R2. @@ -1355,8 +1355,8 @@ else #endif { - requestConcentratePumpOff( CONCENTRATEPUMPS_CP1_ACID, PARK_CONC_PUMPS ); //NO_PARK_CONC_PUMPS ); - requestConcentratePumpOff( CONCENTRATEPUMPS_CP2_BICARB, PARK_CONC_PUMPS ); // NO_PARK_CONC_PUMPS ); + requestConcentratePumpOff( CONCENTRATEPUMPS_CP1_ACID, NO_PARK_CONC_PUMPS ); + requestConcentratePumpOff( CONCENTRATEPUMPS_CP2_BICARB, NO_PARK_CONC_PUMPS ); stopHeater( DG_PRIMARY_HEATER ); stopHeater( DG_TRIMMER_HEATER );