Index: firmware/App/Modes/ModeChemicalDisinfect.c =================================================================== diff -u -rc4f3105da2ed8a7c40950588b54b79067185a3ad -rc940dea020a10f2bab23ae92aa6932c375c26dd4 --- firmware/App/Modes/ModeChemicalDisinfect.c (.../ModeChemicalDisinfect.c) (revision c4f3105da2ed8a7c40950588b54b79067185a3ad) +++ firmware/App/Modes/ModeChemicalDisinfect.c (.../ModeChemicalDisinfect.c) (revision c940dea020a10f2bab23ae92aa6932c375c26dd4) @@ -1367,7 +1367,7 @@ static DG_RESERVOIR_STATUS_T getRsrvrDrainStatus( DG_RESERVOIR_ID_T r, U32 drainSteadyStateTimeout, U32 timeout ) { DG_RESERVOIR_STATUS_T status = DG_RESERVOIR_ABOVE_TARGET; - BOOL isDrainComplete = hasTargetDrainVolumeBeenReached( r, drainSteadyStateTimeout ); + BOOL isDrainComplete = hasTargetDrainToZeroBeenReached( r, drainSteadyStateTimeout ); // If the drain parameters of the reservoir is not initialized, initialize them if ( FALSE == haveDrainParamsBeenInit[ r ] ) Index: firmware/App/Modes/ModeChemicalDisinfectFlush.c =================================================================== diff -u -rc4f3105da2ed8a7c40950588b54b79067185a3ad -rc940dea020a10f2bab23ae92aa6932c375c26dd4 --- firmware/App/Modes/ModeChemicalDisinfectFlush.c (.../ModeChemicalDisinfectFlush.c) (revision c4f3105da2ed8a7c40950588b54b79067185a3ad) +++ firmware/App/Modes/ModeChemicalDisinfectFlush.c (.../ModeChemicalDisinfectFlush.c) (revision c940dea020a10f2bab23ae92aa6932c375c26dd4) @@ -950,7 +950,7 @@ // NOTE: the drain status should be checked once the reservoirs parameters are initialized. This is to make sure the // the timers for stable drain time are initialized prior to using them again - isDrainComplete = hasTargetDrainVolumeBeenReached( r, drainSteadyStateTimeout ); + isDrainComplete = hasTargetDrainToZeroBeenReached( r, drainSteadyStateTimeout ); if ( TRUE == isDrainComplete ) { Index: firmware/App/Modes/ModeFill.c =================================================================== diff -u -re58e3385eaf5e920335f963937b2e9f654a32cfe -rc940dea020a10f2bab23ae92aa6932c375c26dd4 --- firmware/App/Modes/ModeFill.c (.../ModeFill.c) (revision e58e3385eaf5e920335f963937b2e9f654a32cfe) +++ firmware/App/Modes/ModeFill.c (.../ModeFill.c) (revision c940dea020a10f2bab23ae92aa6932c375c26dd4) @@ -8,7 +8,7 @@ * @file ModeFill.c * * @author (last) Dara Navaei -* @date (last) 26-Apr-2023 +* @date (last) 11-May-2023 * * @author (original) Leonardo Baloa * @date (original) 19-Nov-2019 @@ -609,11 +609,14 @@ bicarbConductivitySampleCount = 0; // Set pumps flow rate to prepare for bicarb conductivity testing - setROPumpTargetFlowRateLPM( RO_PUMP_400_ML_PER_MIN / MILLILITERS_PER_LITER, TARGET_RO_PRESSURE_PSI ); + setROPumpTargetFlowRateLPM( RO_PUMP_800_ML_PER_MIN / MILLILITERS_PER_LITER, TARGET_RO_PRESSURE_PSI ); setConcentratePumpTargetSpeed( CONCENTRATEPUMPS_CP2_BICARB, BICARB_PUMP_40_ML_PER_MIN ); requestConcentratePumpOn( CONCENTRATEPUMPS_CP2_BICARB ); + // Prior to collecting data for bicarb test, change the CD2 calibration table + setCondcutivitySensorCalTable( CONDUCTIVITYSENSORS_CD2_SENSOR, CAL_DATA_CD2_COND_SENSOR_FILL_BICARB_TEST ); + // State transition concentrateTestStartTime = getMSTimerCount(); result = DG_FILL_MODE_STATE_TEST_BICARB_CONDUCTIVITY; @@ -680,6 +683,10 @@ setROPumpTargetFlowRateLPM( RO_PUMP_800_ML_PER_MIN / MILLILITERS_PER_LITER, TARGET_RO_PRESSURE_PSI ); setConcentratePumpTargetSpeed( CONCENTRATEPUMPS_CP1_ACID, ACID_PUMP_20_ML_PER_MIN ); requestConcentratePumpOn( CONCENTRATEPUMPS_CP1_ACID ); + + // Set back the conductivity of CD2 calibration table to the normal calibration table + setCondcutivitySensorCalTable( CONDUCTIVITYSENSORS_CD2_SENSOR, CAL_DATA_CD2_COND_SENSOR ); + // State transition concentrateTestStartTime = getMSTimerCount(); result = DG_FILL_MODE_STATE_TEST_ACID_CONDUCTIVITY;