Index: tests/dg_heat_and_chemical_disinfect_test.py =================================================================== diff -u -rd9310e1930f9237650263dcad07f676439468b50 -r107697bd31dc87e450f18cca334025c631a6825d --- tests/dg_heat_and_chemical_disinfect_test.py (.../dg_heat_and_chemical_disinfect_test.py) (revision d9310e1930f9237650263dcad07f676439468b50) +++ tests/dg_heat_and_chemical_disinfect_test.py (.../dg_heat_and_chemical_disinfect_test.py) (revision 107697bd31dc87e450f18cca334025c631a6825d) @@ -1,3 +1,18 @@ +########################################################################### +# +# Copyright (c) 2019-2021 Diality Inc. - All Rights Reserved. +# +# THIS CODE MAY NOT BE COPIED OR REPRODUCED IN ANY FORM, IN PART OR IN +# WHOLE, WITHOUT THE EXPLICIT PERMISSION OF THE COPYRIGHT OWNER. +# +# @file dg_heat_and_chemical_disinfect_test.py +# +# @author (last) Dara Navaei +# @date (last) 30-Jun-2021 +# @author (original) Dara Navaei +# @date (original) 02-May-2021 +# +############################################################################ from dialin.dg.dialysate_generator import DG @@ -11,6 +26,7 @@ from dialin.dg.temperature_sensors import TemperatureSensorsNames from dialin.dg.dialysate_generator import DGOperationModes from dialin.hd.temperatures import HDTemperaturesNames +from dialin.dg.events import DGEvents from time import sleep from datetime import datetime import sys @@ -56,8 +72,9 @@ def get_dg_run_info(): - info = ('DG_op_mode, {}, DG_sub_mode, {}, '.format(DGOperationModes(dg.dg_operation_mode).name, - dg.dg_operation_sub_mode)) + info = ('DG_op_mode, {}, DG_sub_mode, {}, DG_event, {}, '.format(DGOperationModes(dg.dg_operation_mode).name, + dg.dg_operation_sub_mode, + dg.events.get_dg_events())) return info @@ -101,10 +118,10 @@ def get_ro_info(): - info = ('RO, {}, PPi, {:5.3f}, PPo, {:5.3f}, PWM, {:5.3f}, Flow, {:5.3f}, Tgt_flow, {:5.3f}, ' + info = ('RO, {}, PPi, {:5.3f}, PPo, {:5.3f}, PWM, {:5.3f}, Flow, {:5.3f}, Tgt_flow, {:5.3f}, Temp_flow, {:5.3f}, ' .format(dg.ro_pump.ro_pump_state, dg.pressures.ro_pump_inlet_pressure, dg.pressures.ro_pump_outlet_pressure, dg.ro_pump.pwm_duty_cycle_pct, - dg.ro_pump.measured_flow_rate_lpm, dg.ro_pump.target_flow_lpm)) + dg.ro_pump.measured_flow_rate_lpm, dg.ro_pump.target_flow_lpm, dg.ro_pump.temporary_flow_value)) return info @@ -288,7 +305,7 @@ print(var) f.write(var) - if run_number > 5 and dg.dg_operation_sub_mode == 2: + if run_number > 7 and dg.dg_operation_sub_mode == 2: dg.hd_proxy.cmd_start_stop_dg(start=False) f.close() break @@ -528,9 +545,9 @@ #run_chemical_disinfect() - #run_dg() + run_dg() - run_ro_pump_duty_cycles() + #run_ro_pump_duty_cycles() #cmd_set_disinfect_ui_screen()