Index: tests/dg_tests.py =================================================================== diff -u -r63b4319afbaac8d4e6df4eb62978d201d81bd6e8 -r183a3606fd69f41a1f53a31e2e6a001810c48bd6 --- tests/dg_tests.py (.../dg_tests.py) (revision 63b4319afbaac8d4e6df4eb62978d201d81bd6e8) +++ tests/dg_tests.py (.../dg_tests.py) (revision 183a3606fd69f41a1f53a31e2e6a001810c48bd6) @@ -141,7 +141,7 @@ def get_dg_valves_states(): info = ('VPi, {}, VSP, {}, VPd, {}, VBf, {}, VPo, {}, VDr, {}, VRc, {}, VRo, {}, VRd, {}, VRi, {}, VRf, {}, ' - 'VRD1, {}, VRD2, {}, All, {}, ' + 'VRD1, {}, VRD2, {}, ' .format(dg.valves.valve_states_enum[dg.valves.VALVE_PRESSURE_INLET], dg.valves.valve_states_enum[dg.valves.VALVE_SAMPLING_PORT], dg.valves.valve_states_enum[dg.valves.VALVE_PRODUCTION_DRAIN], @@ -154,8 +154,7 @@ dg.valves.valve_states_enum[dg.valves.VALVE_RESERVOIR_INLET], dg.valves.valve_states_enum[dg.valves.VALVE_RESERVOIR_FILL], dg.valves.valve_states_enum[dg.valves.VALVE_RESERVOIR_DRAIN_1], - dg.valves.valve_states_enum[dg.valves.VALVE_RESERVOIR_DRAIN_2], - dg.valves.valves_sensed_states)) + dg.valves.valve_states_enum[dg.valves.VALVE_RESERVOIR_DRAIN_2])) return info @@ -201,8 +200,7 @@ info = ('Pri_main_DC, {:5.3f}, Pri_state, {}, Trimmer_DC, {:5.3f}, Trimmer_state, {}, ' 'Primary_target_temp, {:5.3f}, Trimmer_target_temp, {:5.3f}, Primary_eff, {:5.3f}, ' 'Primary_calc_temp, {:5.3f}, Trimmer_calc_temp, {:5.3f}, Primary_power, {:5.3f}, ' - 'Primary_volt, {:5.3f}, Primary_sec_volt, {:5.3f},' - ' Trimmer_volt, {:5.3f}, ' + 'Primary_volt, {:5.3f}, Primary_sec_volt, {:5.3f}, Trimmer_volt, {:5.3f}, Trimmer_use_last_dc, {}, ' .format(dg.heaters.main_primary_heater_duty_cycle, dg.heaters.primary_heater_state, dg.heaters.trimmer_heater_duty_cycle, dg.heaters.trimmer_heater_state, dg.heaters.primary_heaters_target_temperature, dg.heaters.trimmer_heater_target_temperature, @@ -211,7 +209,8 @@ dg.voltages.monitored_voltages[DGMonitoredVoltages.MONITORED_LINE_24V_POWER_PRIM_HTR_V.value], dg.voltages.monitored_voltages[DGMonitoredVoltages.MONITORED_LINE_24V_GND_MAIN_PRIM_HTR_V.value], dg.voltages.monitored_voltages[DGMonitoredVoltages.MONITORED_LINE_24V_GND_SMALL_PRIM_HTR_V.value], - dg.voltages.monitored_voltages[DGMonitoredVoltages.MONITORED_LINE_24V_GND_TRIM_HTR_V.value])) + dg.voltages.monitored_voltages[DGMonitoredVoltages.MONITORED_LINE_24V_GND_TRIM_HTR_V.value], + dg.heaters.trimmer_use_last_duty_cycle)) return info @@ -436,9 +435,10 @@ fill_info = get_dg_fill_info() idle_bad_fill = get_dg_idle_bad_fill_info() uv = get_uv_reactors_info() + hd_fans = get_hd_fans_info() var = str(datetime.now()) + ', ' + hd_run + dg_run + hd_rsrvrs + dg_rsrvrs + load_cell + drain + ro + \ - temp + heaters + conc_pumps + dg_fans + valves + blood_leak + hd_pumps + fill_info + uv + '\r' + temp + heaters + conc_pumps + dg_fans + valves + blood_leak + hd_pumps + fill_info + uv + hd_fans + '\r' if hd.alarms.get_alarm_state(97) and start is False: dg.conductivity_sensors.cmd_conductivity_sensor_override(ConductivitySensorsEnum.CD2.value, 13700.00) @@ -698,12 +698,12 @@ # cmd_set_disinfect_ui_screen() - #collect_treatment_data() + collect_treatment_data() #collect_hd_treatment() #while True: - # print(get_temperature_sensors_info(), get_dg_fans_info()) + # print(get_hd_fans_info(), get_dg_fans_info()) # sleep(1) #while True: @@ -735,10 +735,10 @@ #sleep(1) #dg.heaters.cmd_start_stop_trimmer_heater(0) - dg.valves.cmd_valve_sensed_state_override(4, 1, reset=0) + #dg.valves.cmd_valve_sensed_state_override(4, 1, reset=0) - while True: - print(get_dg_valves_states()) - sleep(1) + #while True: + # print(get_dg_valves_states()) + # sleep(1)