Index: tests/dg_tests.py =================================================================== diff -u -rab95fd4d07280a6af9a18956a4e55ac9d62823e2 -r34fce4de74f1e249b691f6b8a7618cf0f1454115 --- tests/dg_tests.py (.../dg_tests.py) (revision ab95fd4d07280a6af9a18956a4e55ac9d62823e2) +++ tests/dg_tests.py (.../dg_tests.py) (revision 34fce4de74f1e249b691f6b8a7618cf0f1454115) @@ -42,6 +42,7 @@ from dialin.dg.conductivity_sensors import ConductivitySensorsEnum from dialin.dg.voltages import DGMonitoredVoltages from dialin.hd.valves import HDValves +from dialin.hd.voltages import HDMonitoredVoltages from dialin.hd.pretreatment import PreTreatmentRsrvrState from time import sleep from datetime import datetime @@ -241,13 +242,12 @@ def get_hd_fans_info(): info = ('HD_Fan_DC, {:5.3f}, Target_HD_RPM, {:5.3f}, Inlet1_RPM, {:5.3f}, HD_Board_temp, {:5.3f}, ' - 'HD_Power_supply, {:5.3f}, HD_FPGA_temp, {:5.3f}, PBA_ADC_temp, {:5.3f}, Venous_temp, {:5.3f}, ' + 'HD_Power_supply, {:5.3f}, HD_FPGA_temp, {:5.3f}, Venous_temp, {:5.3f}, ' 'Arterial_temp, {:5.3f}, RPM_time_offset, {}, ' .format(hd.fans.duty_cycle, hd.fans.target_rpm, hd.fans.inlet_1_rpm, hd.temperatures.hd_temperatures[HDTemperaturesNames.THERMISTOR_ONBOARD_NTC.name], hd.temperatures.hd_temperatures[HDTemperaturesNames.THERMISTOR_POWER_SUPPLY_1.name], hd.temperatures.hd_temperatures[HDTemperaturesNames.TEMPSENSOR_FPGA_BOARD.name], - hd.temperatures.hd_temperatures[HDTemperaturesNames.TEMPSENSOR_PBA_ADC_SENSOR.name], hd.temperatures.hd_temperatures[HDTemperaturesNames.TEMPSENSOR_VENOUS_PRESS_TEMP.name], hd.temperatures.hd_temperatures[HDTemperaturesNames.TEMPSENSOR_ARTERIAL_PRESS_TEMP.name], hd.fans.rpm_alarm_time)) @@ -291,9 +291,11 @@ def get_hd_pumps_info(): - info = ('DialIn_tgt_flow, {}, DialIn_meas_flow, {:5.3f}, ' + info = ('DialIn_tgt_flow, {}, DialIn_meas_flow, {:5.3f}, DialIn_current, {:5.3f}, DialOut_current, {:5.3f}, ' .format(hd.dialysate_inlet_flow.target_dialysate_inlet_flow_rate, - hd.dialysate_inlet_flow.measured_dialysate_inlet_flow_rate)) + hd.dialysate_inlet_flow.measured_dialysate_inlet_flow_rate, + hd.dialysate_inlet_flow.measured_dialysate_inlet_pump_mc_current, + hd.dialysate_outlet_flow.measured_dialysate_outlet_pump_mc_current)) return info @@ -312,6 +314,12 @@ return info +def get_voltages_info(): + info = ('HD_24, {:5.3f}, HD_24_regen, {:5.3f}, '. + format(hd.voltages.monitored_voltages[HDMonitoredVoltages.MONITORED_LINE_24V.value], + hd.voltages.monitored_voltages[HDMonitoredVoltages.MONITORED_LINE_24V_REGEN.value])) + return info + def run_dg(): counter = 1 timer = 0.1 @@ -447,20 +455,29 @@ #hd.cmd_hd_software_reset_request() + hd.dialysate_inlet_flow.cmd_dialysate_inlet_flow_broadcast_interval_override(50) + sleep(1) + hd.dialysate_outlet_flow.cmd_dialysate_outlet_flow_broadcast_interval_override(50) + sleep(1) + hd.voltages.cmd_monitored_voltages_broadcast_interval_override(50) + try: while True: - sleep(1) + hd_run = get_hd_run_info() + pumps_info = get_hd_pumps_info() + voltages = get_voltages_info() + var = hd_run + pumps_info + voltages + '\r' + print(var) + f.write(var) + sleep(0.05) except KeyboardInterrupt: - events = hd.hd_events.get_hd_events(2, 0) - for event in events: - print(event) f.close() def run_heat_disinfect(): complete_counter = 1 f = open("/home/fw/projects/dialin/tests/Heat_disinfect.log", "w") - dg.hd_proxy.cmd_start_stop_dg_heat_disinfect() + #dg.hd_proxy.cmd_start_stop_dg_heat_disinfect() try: while True: @@ -651,7 +668,7 @@ #run_heat_disinfect() - # run_chemical_disinfect() + #run_chemical_disinfect() #run_dg() @@ -669,11 +686,15 @@ # print(get_new_ro_info(), get_ro_info()) # sleep(1) - # test_dg_fans_alarms() + while True: + print(dg.rtc.get_rtc_epoch(), hd.rtc.get_rtc_epoch()) + sleep(1) + #test_dg_fans_alarms() + #test_dvt_drain_pump() - test_conc_pumps() + #test_conc_pumps() #while True: # print(get_concentrate_pumps_info()) @@ -684,5 +705,7 @@ #test_hd_valves() + #while True: + # print(get_heaters_info()) + # sleep(1) -