Index: tests/hd_nvm_scripts.py =================================================================== diff -u -rddf8a289ffc27f86d69a60922ce71d1681b668ce -r6d6c2318a81c130b7875bfad31424e56fd8f59f2 --- tests/hd_nvm_scripts.py (.../hd_nvm_scripts.py) (revision ddf8a289ffc27f86d69a60922ce71d1681b668ce) +++ tests/hd_nvm_scripts.py (.../hd_nvm_scripts.py) (revision 6d6c2318a81c130b7875bfad31424e56fd8f59f2) @@ -1,28 +1,58 @@ from dialin import HD -if __name__ == "__main__": - hd = HD(log_level="DEBUG") +def run_sw_configs_commands(): + # NOTE: For further details, please refer to 'Instructions to Change the Software Configurations Dynamically' in + # the development section of the DevOps OneNote file - if hd.cmd_log_in_to_hd(): + # Comment and un-comment any of the functions that you would like to use or you can use your own scripts. - # NOTE: For further details, please refer to 'Instructions to Change the Software Configurations Dynamically' in - # the development section of the DevOps OneNote file + # Use cmd_get_hd_sw_config_record() to get the software configurations record in an excel + # This function gets an address to locate the report there (i.e. /home/fw/projects/) + # It creates a folder called HD_NV_Records in the destination that is called + # If no address is provided, the default location is one folder above the dialin folder wherever it is installed + # in your computer. + hd.sw_configs.cmd_get_hd_sw_config_record() - # Comment and un-comment any of the functions that you would like to use or you can use your own scripts. + # Use cmd_update_hd_sw_config_record() set the changes back to firmware + # This function requires an address for the excel report. Use the absolute address of your excel report like the + # example below + #hd.sw_configs.cmd_update_hd_sw_config_record('/home/fw/projects/HD_NV_Records/2022-02-14-HD-SW-CONFIGS-Record.xlsx') - # Use cmd_get_hd_sw_config_record() to get the software configurations record in an excel - # This function gets an address to locate the report there (i.e. /home/fw/projects/) - # It creates a folder called HD_NV_Records in the destination that is called - # If no address is provided, the default location is one folder above the dialin folder wherever it is installed - # in you computer. - #hd.sw_configs.cmd_get_hd_sw_config_record() + # Use this function to reset the configuration records to all be 0 + # hd.sw_configs.cmd_reset_hd_sw_config_record() - # Use cmd_update_hd_sw_config_record() set the changes back to firmware - # This function requires an address for the excel report. Use the absolute address of your excel report like the - # example below - hd.sw_configs.cmd_update_hd_sw_config_record('/home/fw/projects/HD_NV_Records/2022-02-14-HD-SW-CONFIGS-Record.xlsx') - # Use this function to reset the configuration records to all be 0 - #hd.sw_configs.cmd_reset_hd_sw_config_record() +def run_calibration_commands(): + # NOTE: For further details, please refer to 'Instructions to Calibrate a Device Using the Calibration Report' + # in the development section of the DevOps OneNote file + # Comment and un-comment any of the functions that you would like to use or you can use your own scripts. + + # Use cmd_get_dg_calibration_record_report() to get the calibration record in an excel + # This function gets an address to locate the report there (i.e. /home/fw/projects/) + # It creates a folder called HD_NV_Records in the destination that is called + # If no address is provided, the default location is one folder above the dialin folder wherever it is installed + # in your computer. + hd.calibration_record.cmd_get_hd_calibration_record_report() + + # Use cmd_set_hd_calibration_excel_to_fw() set the changes back to firmware + # This function requires an address for the excel report. Use the absolute address of your excel report like the + # example below + #hd.calibration_record.cmd_set_hd_calibration_excel_to_fw('/home/fw/projects/HD_NV_Records/2022-02-21-HD-Record.xlsx') + + # For resetting the calibration record to benign values, use the function below + #hd.calibration_record.cmd_reset_hd_calibration_record() + + +if __name__ == "__main__": + + hd = HD(log_level="DEBUG") + + if hd.cmd_log_in_to_hd(): + + # Comment this function if not needed + run_sw_configs_commands() + + # Comment this function if not needed + #run_calibration_commands()