Index: tools/Code_Report.csv =================================================================== diff -u -reb7088d107c8fc612d5cc9b764283298bf23ddea -rbd5dbef63b70c3c6c6435a184b9c4f060e5455d6 --- tools/Code_Report.csv (.../Code_Report.csv) (revision eb7088d107c8fc612d5cc9b764283298bf23ddea) +++ tools/Code_Report.csv (.../Code_Report.csv) (revision bd5dbef63b70c3c6c6435a184b9c4f060e5455d6) @@ -298,6 +298,7 @@ ./hd/battery.py, Function, cmd_battery_comm_status_override(self, status: int, reset: int = NO_RESET) -> int: ./hd/blood_flow.py, Function, get_pwm_duty_cycle_pct(self): ./hd/blood_flow.py, Function, get_rotor_count(self): +./hd/blood_flow.py, Function, get_pres_blood_flow_rate(self): ./hd/blood_flow.py, Function, cmd_blood_flow_set_point_override(self, flow: int, mode: int = PUMP_CONTROL_MODE_CLOSED_LOOP, ./hd/blood_flow.py, Function, cmd_blood_flow_measured_override(self, flow: int, reset: int = NO_RESET) -> int: ./hd/blood_flow.py, Function, cmd_blood_pump_measured_motor_controller_speed_override(self, speed: int, reset: int = NO_RESET) -> int: @@ -334,6 +335,7 @@ ./hd/calibration_record.py, Function, cmd_get_hd_calibration_record_report(self, report_destination: str = None): ./hd/dialysate_inlet_flow.py, Function, get_pwm_duty_cycle_pct(self): ./hd/dialysate_inlet_flow.py, Function, get_rotor_count(self): +./hd/dialysate_inlet_flow.py, Function, get_pres_dialysate_flow_rate(self): ./hd/dialysate_inlet_flow.py, Function, cmd_dialysate_inlet_flow_set_point_override(self, ./hd/dialysate_inlet_flow.py, Function, cmd_dialysate_inlet_flow_measured_override(self, flow: int, reset: int = NO_RESET) -> int: ./hd/dialysate_inlet_flow.py, Function, cmd_dialysate_inlet_pump_measured_motor_controller_speed_override(self, speed: int, @@ -928,6 +930,7 @@ hd/blood_flow.py, Variable, measured_blood_pump_mc_current hd/blood_flow.py, Variable, pwm_duty_cycle_pct hd/blood_flow.py, Variable, rotor_count +hd/blood_flow.py, Variable, pres_blood_flow_rate hd/blood_leak.py, Variable, blood_leak_status hd/blood_leak.py, Variable, blood_leak_state hd/blood_leak.py, Variable, blood_leak_emb_mode_cmds @@ -942,6 +945,7 @@ hd/dialysate_inlet_flow.py, Variable, measured_dialysate_inlet_pump_mc_current hd/dialysate_inlet_flow.py, Variable, pwm_duty_cycle_pct hd/dialysate_inlet_flow.py, Variable, rotor_count +hd/dialysate_inlet_flow.py, Variable, pres_dialysate_flow_rate hd/dialysate_outlet_flow.py, Variable, reference_dialysate_outlet_uf_volume hd/dialysate_outlet_flow.py, Variable, measured_dialysate_outlet_uf_volume hd/dialysate_outlet_flow.py, Variable, measured_dialysate_outlet_pump_rotor_speed