Index: tests/dg_tests.py =================================================================== diff -u -r621bb43cdd732ac9f81c4b2d0912c52bbbb084ab -rc0e18c09e54b46dfb97ae7024303873225ef03b6 --- tests/dg_tests.py (.../dg_tests.py) (revision 621bb43cdd732ac9f81c4b2d0912c52bbbb084ab) +++ tests/dg_tests.py (.../dg_tests.py) (revision c0e18c09e54b46dfb97ae7024303873225ef03b6) @@ -782,5 +782,6 @@ # print(hd.alarms.get_alarm_state(286), hd.alarms.get_alarm_state(289), dg.alarms.get_alarm_state(286), # dg.alarms.get_alarm_state(289)) # sleep(0.5) - hd.test_configs.cmd_set_test_config(HDTestConfigOptions.TEST_CONFIG_SKIP_DISINFECT_AND_SERVICE_TX_BLOCKERS.value) - dg.cmd_dg_set_operation_mode(1) + #hd.test_configs.cmd_set_test_config(HDTestConfigOptions.TEST_CONFIG_SKIP_DISINFECT_AND_SERVICE_TX_BLOCKERS.value) + #dg.cmd_dg_set_operation_mode(3) + hd.cmd_hd_set_operation_mode(1) Index: tests/hd_nvm_scripts.py =================================================================== diff -u -r621bb43cdd732ac9f81c4b2d0912c52bbbb084ab -rc0e18c09e54b46dfb97ae7024303873225ef03b6 --- tests/hd_nvm_scripts.py (.../hd_nvm_scripts.py) (revision 621bb43cdd732ac9f81c4b2d0912c52bbbb084ab) +++ tests/hd_nvm_scripts.py (.../hd_nvm_scripts.py) (revision c0e18c09e54b46dfb97ae7024303873225ef03b6) @@ -50,12 +50,12 @@ # It creates a folder called HD_NV_Records in the destination that is called # If no address is provided, the default location is one folder above the dialin folder wherever it is installed # in your computer. - #hd.calibration_record.cmd_get_hd_calibration_record_report() + hd.calibration_record.cmd_get_hd_calibration_record_report() # Use cmd_set_hd_calibration_excel_to_fw() set the changes back to firmware # This function requires an address for the excel report. Use the absolute address of your excel report like the # example below - hd.calibration_record.cmd_set_hd_calibration_excel_to_fw('/home/fw/projects/HD_NV_Records/2024-02-27-HD-Record.xlsx') + #hd.calibration_record.cmd_set_hd_calibration_excel_to_fw('/home/fw/projects/HD_NV_Records/2024-02-27-HD-Record.xlsx') # For resetting the calibration record to benign values, use the function below #hd.calibration_record.cmd_reset_hd_calibration_record() @@ -111,7 +111,7 @@ #hd.institutional_record.cmd_get_hd_institutional_record() - hd.institutional_record.cmd_set_hd_institutional_record_excel_to_fw('/home/fw/projects/HD_NV_Records/2024-02-29-HD-Record.xlsx') + hd.institutional_record.cmd_set_hd_institutional_record_excel_to_fw('/home/fw/projects/HD_NV_Records/2024-03-18-HD-Record.xlsx') #hd.institutional_record.cmd_reset_hd_institutional_record()