Index: tools/Code_Report.csv =================================================================== diff -u -r0f5ebacfd87c640894d9d690371bf56a52e19005 -rf907f54529f4534126c183c5a816722b5fa5baf8 --- tools/Code_Report.csv (.../Code_Report.csv) (revision 0f5ebacfd87c640894d9d690371bf56a52e19005) +++ tools/Code_Report.csv (.../Code_Report.csv) (revision f907f54529f4534126c183c5a816722b5fa5baf8) @@ -44,10 +44,11 @@ ./dg/concentrate_pumps.py, Function, cmd_concentrate_pump_broadcast_interval_override(self, ms: int, reset: int = NO_RESET) -> int: ./dg/concentrate_pumps.py, Function, get_concentrate_pumps(self): ./dg/concentrate_pumps.py, Function, get_concentrate_pumps_parked(self): +./dg/conductivity_sensors.py, Function, get_ro_rejection_ratio(self): ./dg/conductivity_sensors.py, Function, cmd_conductivity_sensor_override(self, sensor: int, conductivity: float, reset: int = NO_RESET) -> int: ./dg/conductivity_sensors.py, Function, cmd_conductivity_sensor_data_broadcast_interval_override(self, ms: int, reset: int = NO_RESET) -> int: +./dg/conductivity_sensors.py, Function, cmd_set_conductivity_sensor_cal_table(self, sensor_id: int, cal_table_id: int): ./dg/conductivity_sensors.py, Function, get_conductivity_sensors(self): -./dg/conductivity_sensors.py, Function, get_ro_rejection_ratio(self): ./dg/cpld.py, Function, get_cpld_wdog(self) -> int: ./dg/cpld.py, Function, get_cpld_audio(self) -> int: ./dg/cpld.py, Function, get_cpld_fault_led(self) -> int: @@ -155,9 +156,11 @@ ./dg/heaters.py, Function, cmd_heaters_broadcast_interval_override(self, ms: int, reset: int = NO_RESET) -> int: ./dg/heaters.py, Function, get_main_primary_heater_duty_cycle(self): ./dg/heaters.py, Function, get_small_primary_heater_duty_cycle(self): +./dg/load_cells.py, Function, cmd_load_cell_override(self, sensor: int, grams: float, raw: int, reset: int = NO_RESET) -> int: ./dg/load_cells.py, Function, cmd_load_cell_data_broadcast_interval_override(self, ms: int, reset: int = NO_RESET) -> int: +./dg/load_cells.py, Function, cmd_set_load_cells_tare_values(self): +./dg/load_cells.py, Function, cmd_get_load_cells_tare_values(self): ./dg/load_cells.py, Function, get_load_cells(self): -./dg/load_cells.py, Function, cmd_load_cell_override(self, sensor: int, grams: float, raw: int, reset: int = NO_RESET) -> int: ./dg/pressures.py, Function, cmd_pressure_override(self, sensor: int, pressure: int, reset: int = NO_RESET) -> int: ./dg/pressures.py, Function, cmd_pressure_broadcast_interval_override(self, ms: int, reset: int = NO_RESET) -> int: ./dg/pressures.py, Function, get_pressures(self): @@ -567,7 +570,7 @@ ./hd/ui_proxy.py, Function, cmd_ui_blood_and_dialysate_flow_settings_change_request(self, blood_flow: int, dial_flow: int) -> None: ./hd/ui_proxy.py, Function, cmd_ui_initiate_treatment_request(self, cmnd: int = 1) -> None: ./hd/ui_proxy.py, Function, set_a_treatment_parameter(self, param_idx: int, value: int) -> None: -./hd/ui_proxy.py, Function, cmd_set_treatment_parameters(self, bld_flow: int = 100, +./hd/ui_proxy.py, Function, cmd_set_treatment_parameters(self, bld_flow: int = 350, ./hd/ui_proxy.py, Function, cmd_ui_confirm_treatment_parameters(self, cmd: int = 0) -> None: ./hd/ui_proxy.py, Function, cmd_ui_request_saline_bolus(self, start: bool = False) -> None: ./hd/ui_proxy.py, Function, cmd_ui_rinseback_user_action( @@ -866,6 +869,9 @@ dg/load_cells.py, Variable, load_cell_A2 dg/load_cells.py, Variable, load_cell_B1 dg/load_cells.py, Variable, load_cell_B2 +dg/load_cells.py, Variable, load_cells_tare_values +dg/load_cells.py, Variable, dg_load_cells_tare_values_timestamp +dg/load_cells.py, Variable, load_cells_tare_values[cell] dg/pressures.py, Variable, ro_pump_inlet_pressure dg/pressures.py, Variable, ro_pump_outlet_pressure dg/pressures.py, Variable, drain_pump_inlet_pressure @@ -2697,15 +2703,24 @@ common/msg_ids.py, Enum, MsgIds, MSG_ID_DG_SEND_TEST_CONFIGURATION common/msg_ids.py, Enum, MsgIds, MSG_ID_DG_RESET_ALL_TEST_CONFIGURATIONS common/msg_ids.py, Enum, MsgIds, MSG_ID_DG_DIALIN_CHECK_IN +common/msg_ids.py, Enum, MsgIds, MSG_ID_DG_GET_LOAD_CELLS_TARE_VALUES +common/msg_ids.py, Enum, MsgIds, MSG_ID_DG_SET_LOAD_CELLS_TARE_VALUES +common/msg_ids.py, Enum, MsgIds, MSG_ID_DG_SEND_LOAD_CELLS_TARE_VALUES_TO_DIALIN +common/msg_ids.py, Enum, MsgIds, MSG_ID_DG_SET_COND_SENSOR_CAL_TABLE common/msg_ids.py, Enum, MsgIds, MSG_ID_HD_DEBUG_EVENT common/msg_ids.py, Enum, MsgIds, MSG_ID_DG_DEBUG_EVENT common/msg_ids.py, Enum, MsgIds, MSG_ID_ACK_MESSAGE_THAT_REQUIRES_ACK common/test_config_defs.py, Enum, DGTestConfigOptions, DGTestConfigOptions -common/test_config_defs.py, Enum, DGTestConfigOptions, TEST_CONFIG_ENABLE_MIXING_WITH_WATER +common/test_config_defs.py, Enum, DGTestConfigOptions, TEST_CONFIG_MIX_WITH_WATER +common/test_config_defs.py, Enum, DGTestConfigOptions, TEST_CONFIG_DISABLE_INLET_WATER_TEMP_CHECK common/test_config_defs.py, Enum, DGTestConfigOptions, NUM_OF_TEST_CONFIGS common/test_config_defs.py, Enum, HDTestConfigOptions, HDTestConfigOptions common/test_config_defs.py, Enum, HDTestConfigOptions, TEST_CONFIG_USE_WET_CARTRIDGE common/test_config_defs.py, Enum, HDTestConfigOptions, TEST_CONFIG_USE_WORN_CARTRIDGE +common/test_config_defs.py, Enum, HDTestConfigOptions, TEST_CONFIG_EXPEDITE_PRE_TREATMENT +common/test_config_defs.py, Enum, HDTestConfigOptions, TEST_CONFIG_SKIP_BLOOD_PRIME +common/test_config_defs.py, Enum, HDTestConfigOptions, TEST_CONFIG_SKIP_DISINFECT_AND_SERVICE_TX_BLOCKERS +common/test_config_defs.py, Enum, HDTestConfigOptions, TEST_CONFIG_DISABLE_WET_SELFTEST_DISPLACEMENT_CHECK common/test_config_defs.py, Enum, HDTestConfigOptions, NUM_OF_TEST_CONFIGS dg/chemical_disinfect.py, Enum, ChemCancellationModes, ChemCancellationModes dg/chemical_disinfect.py, Enum, ChemCancellationModes, CANCELLATION_MODE_NONE @@ -2726,6 +2741,15 @@ dg/conductivity_sensors.py, Enum, ConductivitySensorsEnum, CPO dg/conductivity_sensors.py, Enum, ConductivitySensorsEnum, CD1 dg/conductivity_sensors.py, Enum, ConductivitySensorsEnum, CD2 +dg/conductivity_sensors.py, Enum, ConductivitySensorsEnum, NUM_OF_CONDUCTIVITY_SENSORS +dg/conductivity_sensors.py, Enum, ConductivitySensorsCalTableName, ConductivitySensorsCalTableName +dg/conductivity_sensors.py, Enum, ConductivitySensorsCalTableName, CAL_DATA_CPI_COND_SENSOR +dg/conductivity_sensors.py, Enum, ConductivitySensorsCalTableName, CAL_DATA_CPO_COND_SENSOR +dg/conductivity_sensors.py, Enum, ConductivitySensorsCalTableName, CAL_DATA_CD1_COND_SENSOR +dg/conductivity_sensors.py, Enum, ConductivitySensorsCalTableName, CAL_DATA_CD2_COND_SENSOR +dg/conductivity_sensors.py, Enum, ConductivitySensorsCalTableName, CAL_DATA_CD2_COND_SENSOR_CHEM_DISINFECT +dg/conductivity_sensors.py, Enum, ConductivitySensorsCalTableName, CAL_DATA_CD2_COND_SENSOR_FILL_BICARB_TEST +dg/conductivity_sensors.py, Enum, ConductivitySensorsCalTableName, NUM_OF_CAL_DATA_COND_SENSORS dg/cpld.py, Enum, CPLD_LED_COLORS, CPLD_LED_COLORS dg/cpld.py, Enum, CPLD_LED_COLORS, CPLD_LED_COLOR_OFF dg/cpld.py, Enum, CPLD_LED_COLORS, CPLD_LED_COLOR_ORANGE_HEAT_DISINFECT @@ -2815,6 +2839,12 @@ dg/heaters.py, Enum, HeatersNames, DG_PRIMARY_HEATER dg/heaters.py, Enum, HeatersNames, DG_TRIMMER_HEATER dg/heaters.py, Enum, HeatersNames, NUM_OF_DG_HEATERS +dg/load_cells.py, Enum, DGLoadCellNames, DGLoadCellNames +dg/load_cells.py, Enum, DGLoadCellNames, LOAD_CELL_RESERVOIR_1_PRIMARY +dg/load_cells.py, Enum, DGLoadCellNames, LOAD_CELL_RESERVOIR_1_BACKUP +dg/load_cells.py, Enum, DGLoadCellNames, LOAD_CELL_RESERVOIR_2_PRIMARY +dg/load_cells.py, Enum, DGLoadCellNames, LOAD_CELL_RESERVOIR_2_BACKUP +dg/load_cells.py, Enum, DGLoadCellNames, NUM_OF_LOAD_CELLS dg/reservoirs.py, Enum, DGReservoirsNames, DGReservoirsNames dg/reservoirs.py, Enum, DGReservoirsNames, RESERVOIR1 dg/reservoirs.py, Enum, DGReservoirsNames, RESERVOIR2