Index: firmware/App/Controllers/PresOccl.c =================================================================== diff -u -r24b2fe72608344e67ef37234085d15ad5e4fcc37 -rbd241ef5231a9869adaf7bb5ed166135beb2c0fb --- firmware/App/Controllers/PresOccl.c (.../PresOccl.c) (revision 24b2fe72608344e67ef37234085d15ad5e4fcc37) +++ firmware/App/Controllers/PresOccl.c (.../PresOccl.c) (revision bd241ef5231a9869adaf7bb5ed166135beb2c0fb) @@ -363,15 +363,7 @@ // Check for stale arterial pressure reading if ( FALSE == isPersistentAlarmTriggered( ALARM_ID_HD_VENOUS_PRESSURE_READ_TIMEOUT_ERROR, ( lastArterialPressureReadCtr == artReadCtr || artErrorCtr > 0 ) ) ) { -#ifndef PBA_ESTIMATION arterialPressure.data = ARTERIAL_PRESSURE_V_PER_BIT * ( (F32)(artPres) / ( ARTERIAL_PRESSURE_SENSITIVITY * ARTERIAL_PRESSURE_V_BIAS ) ) + getF32OverrideValue( &arterialPressureOffset ); -#else - // TODO - temporary test code - remove later - F32 artPres = -0.1146 * getMeasuredBloodPumpMCSpeed(); - artPres = MAX(-200.0,artPres); - artPres = MIN(0,artPres); - arterialPressure.data = artPres; -#endif } else { @@ -468,7 +460,7 @@ { F32 artPres = getFilteredArterialPressure(); -#ifndef DISABLE_PRESSURE_CHECKS +#ifndef DISABLE_ARTERIAL_PRESSURE_CHECK // Check arterial pressure is in range if ( TRUE == isPersistentAlarmTriggered( ALARM_ID_HD_ARTERIAL_PRESSURE_OUT_OF_RANGE, ( artPres > ARTERIAL_PRESSURE_MAX_MMHG || artPres < ARTERIAL_PRESSURE_MIN_MMHG ) ) ) @@ -513,15 +505,15 @@ { F32 venPres = getFilteredVenousPressure(); -#ifndef DISABLE_PRESSURE_CHECKS - // Check arterial pressure is in range +#ifndef DISABLE_VENOUS_PRESSURE_CHECK + // Check venous pressure is in range if ( TRUE == isPersistentAlarmTriggered( ALARM_ID_HD_VENOUS_PRESSURE_OUT_OF_RANGE, venPres > VENOUS_PRESSURE_MAX_MMHG ) || TRUE == isPersistentAlarmTriggered( ALARM_ID_HD_VENOUS_PRESSURE_OUT_OF_RANGE, venPres < VENOUS_PRESSURE_MIN_MMHG ) ) { SET_ALARM_WITH_1_F32_DATA( ALARM_ID_HD_VENOUS_PRESSURE_OUT_OF_RANGE, venPres ); } - // Check arterial pressure during treatment mode + // Check venous pressure during treatment mode if ( ( MODE_TREA == getCurrentOperationMode() ) && ( getTreatmentState() <= TREATMENT_DIALYSIS_STATE ) ) { F32 venLowLimit = (F32)getTreatmentParameterS32( TREATMENT_PARAM_VEN_PRESSURE_LOW_LIMIT ); @@ -576,11 +568,11 @@ if ( bpOccl > ( OCCLUSION_THRESHOLD_OFFSET + bloodPumpOcclusionAfterCartridgeInstall ) ) { signalBloodPumpHardStop(); // Stop pump immediately - SET_ALARM_WITH_1_U32_DATA( ALARM_ID_OCCLUSION_BLOOD_PUMP, bpOccl ) + //SET_ALARM_WITH_1_U32_DATA( ALARM_ID_OCCLUSION_BLOOD_PUMP, bpOccl ) } else if ( bpOccl < ( OCCLUSION_CLEAR_THRESHOLD_OFFSET + bloodPumpOcclusionAfterCartridgeInstall ) ) { - clearAlarmCondition( ALARM_ID_OCCLUSION_BLOOD_PUMP ); + //clearAlarmCondition( ALARM_ID_OCCLUSION_BLOOD_PUMP ); } #endif }