Index: firmware/App/HDCommon.h =================================================================== diff -u -r0777f4cdb777147312925391be3422cc5b52a401 -r3cdfce9c1c4fa0fd205756eb458ac5d3bffc9045 --- firmware/App/HDCommon.h (.../HDCommon.h) (revision 0777f4cdb777147312925391be3422cc5b52a401) +++ firmware/App/HDCommon.h (.../HDCommon.h) (revision 3cdfce9c1c4fa0fd205756eb458ac5d3bffc9045) @@ -48,17 +48,17 @@ #define DISABLE_ACK_ERRORS 1 // Do not error on failure of other node(s) to ACK a message // #define RUN_BP_OPEN_LOOP 1 // Run blood pump in open loop mode // #define RUN_DPI_OPEN_LOOP 1 // Run dialysate inlet pump in open loop mode -// #define WORN_OUT_CARTRIDGE 1 // Running with an old worn out cartridge (max wear) + #define WORN_OUT_CARTRIDGE 1 // Running with an old worn out cartridge (max wear) // #define PBA_ESTIMATION 1 // Estimate arterial pressure rather than look at PBA sensor #define DISABLE_MOTOR_CURRENT_CHECKS 1 // Do not error on HD pump current checks #define DISABLE_PUMP_FLOW_CHECKS 1 // Do not error on HD pump flow checks #define DISABLE_PUMP_SPEED_CHECKS 1 // Do not error on HD pump speed checks #define DISABLE_PUMP_DIRECTION_CHECKS 1 // Do not error on HD pump direction checks #define DISABLE_SYRINGE_PUMP 1 // Disable syringe pump functionality #define ALWAYS_ALLOW_SYRINGE_PUMP_CMDS 1 // Allow syringe pump commands at any time except when pump is busy - #define DISABLE_UF_ALARMS 1 // Do not error on HD ultrafiltration checks - #define DISABLE_DIALYSATE_TEMP_CHECK 1 // Disable dialysate temperature check #define DISABLE_PRESSURE_CHECKS 1 // Do not error on HD pressure checks +// #define DISABLE_UF_ALARMS 1 // Do not error on HD ultrafiltration checks + #define DISABLE_DIALYSATE_TEMP_CHECK 1 // Disable dialysate temperature check #define DISABLE_VALVE_ALARMS 1 // Do not error on HD valve position #define SKIP_CAL_CHECK 1 // // #define RUN_PUMPS_OPEN_LOOP 1 // BP and DPi pumps will be run open loop (no flow sensor feedback) @@ -73,12 +73,13 @@ // #define DISABLE_FPGA_COUNTER_CHECKS 1 // Disable alarms associated with FPGA read/error counters #define DISABLE_VOLTAGE_MONITOR 1 // Disable voltage monitoring/alarms #define ALLOW_1_MIN_TREATMENT_DURATION 1 // Allow user to change treatment duration to as low as 1 minute -// #define DISABLE_SYRINGE_PUMP_ALARMS 1 // Disable some syringe pump alarms that are triggering intermittently - #define NO_PUMP_FLOW_LIMITS 1 // Allow any commanded flow rate for peristaltic pumps + #define DISABLE_SYRINGE_PUMP_ALARMS 1 // Disable some syringe pump alarms that are triggering intermittently +// #define NO_PUMP_FLOW_LIMITS 1 // Allow any commanded flow rate for peristaltic pumps #define DISABLE_BUBBLE_ALARMS 1 // Disable bubble alarms #define DISABLE_UI_POST_TEST 1 // Disable the UI POST // #define DISABLE_UI_COMM_TO_ALARM 1 // Disable UI comm timeouts #define DISABLE_WD_AND_SFTY_POST_TESTS 1 // Disable watchdog and safety shutdown POST tests + #define DISABLE_ILLEGAL_AIR_TRAP_ALARM 1 // Disable illegal state for air trap alarm // Skip Pre-Treatment and get to treatment as soon as possible #define SKIP_UI_INTERACTION 1 // Skip UI interaction.