Index: firmware/App/HDCommon.h =================================================================== diff -u -r320cbdabca36d3a79bbdb04a6580f7e69561b259 -r07e300aea17e29b411908d3dbf3e7e47eb6beded --- firmware/App/HDCommon.h (.../HDCommon.h) (revision 320cbdabca36d3a79bbdb04a6580f7e69561b259) +++ firmware/App/HDCommon.h (.../HDCommon.h) (revision 07e300aea17e29b411908d3dbf3e7e47eb6beded) @@ -37,13 +37,13 @@ // #define RUN_WITHOUT_DG 1 // Run HD w/o DG // #define SIMULATE_UI 1 // Build w/o requirement that UI be there // #define TASK_TIMING_OUTPUT_ENABLED 1 // Re-purposes alarm lamp pins for task timing - #define DISABLE_ALARM_AUDIO 1 // Disable alarm audio -// #define SKIP_POST 1 // Skip POST tests - all pass -// #define DONT_SKIP_NV_POST 1 // Do not skip NV Data POST +// #define DISABLE_ALARM_AUDIO 1 // Disable alarm audio + #define SKIP_POST 1 // Skip POST tests - all pass + #define DONT_SKIP_NV_POST 1 // Do not skip NV Data POST #define DISABLE_AIR_TRAP_LEVELING_ALARM 1 // Disable air trap level control alarms // #define DISABLE_3WAY_VALVES 1 // Disable 3-way valves // #define TST_3WAY_VALVES_ALWAYS_OPEN 1 // After POST and homing, open all 4 valves -// #define DISABLE_ACCELS 1 // Disable accelerometer POST and monitoring + #define DISABLE_ACCELS 1 // Disable accelerometer POST and monitoring // #define DISABLE_CRC_ERROR 1 // Do not error on bad CRC for CAN messages // #define DISABLE_ACK_ERRORS 1 // Do not error on failure of other node(s) to ACK a message #define DISABLE_MOTOR_CURRENT_CHECKS 1 // Do not error on HD pump current checks @@ -52,9 +52,9 @@ #define DISABLE_PUMP_DIRECTION_CHECKS 1 // Do not error on HD pump direction checks #define DISABLE_SYRINGE_PUMP 1 // Disable syringe pump functionality #define ALWAYS_ALLOW_SYRINGE_PUMP_CMDS 1 // Allow syringe pump commands at any time except when pump is busy -// #define DISABLE_PRESSURE_CHECKS 1 // Do not error on HD pressure checks -// #define DISABLE_UF_ALARMS 1 // Do not error on HD ultrafiltration checks -// #define DISABLE_VALVE_ALARMS 1 // Do not error on HD valve position + #define DISABLE_PRESSURE_CHECKS 1 // Do not error on HD pressure checks + #define DISABLE_UF_ALARMS 1 // Do not error on HD ultrafiltration checks + #define DISABLE_VALVE_ALARMS 1 // Do not error on HD valve position #define DISABLE_CAL_CHECK 1 // Disable calibration checks // #define RUN_PUMPS_OPEN_LOOP 1 // BP and DPi pumps will be run open loop (no flow sensor feedback) // #define RAW_FLOW_SENSOR_DATA 1 // Test build will not filter flow sensor data @@ -63,22 +63,22 @@ #define ALARMS_DEBUG 1 // Triggered alarms sent to debug UART #define ALARM_VOLUME_DEFAULT_LOW 1 // Set default alarm volume to lowest // #define TEMP_UI_ALARM_SILENCE_FIX 1 // Temporary UI fix for handling alarm silence request msg -// #define SKIP_PRIMING 1 // Skip Pre-treatment Prime + #define SKIP_PRIMING 1 // Skip Pre-treatment Prime #define SKIP_WET_SELF_TESTS 1 // Skip Pre-treatment prime wet self-tests -// #define V2_0_SYSTEM 1 // Build for v2.0 system -// #define SKIP_SAMPLE_WATER 1 // Skip pre-treatment sample water + #define V2_0_SYSTEM 1 // Build for v2.0 system + #define SKIP_SAMPLE_WATER 1 // Skip pre-treatment sample water #define SKIP_CONSUMABLE_TESTS 1 // Skip pre-treatment consumable Self-tests #define SKIP_DRY_SELF_TESTS 1 // Skip pre-treatment dry self-tests -// #define SKIP_UI_INTERACTION 1 // Skip UI interaction. -// #define DISABLE_BATT_COMM 1 // Disable battery communication. + #define SKIP_UI_INTERACTION 1 // Skip UI interaction. + #define DISABLE_BATT_COMM 1 // Disable battery communication. #define SKIP_AIR_BUBBLE_CHECK 1 // Skip air bubble detector self-test. #define DISABLE_OCCLUSION_SELF_TEST 1 // Skip occlusion sensor self-test. -// #define SKIP_CARTRIDGE_REMOVAL 1 // Skip cartridge removal check + #define SKIP_CARTRIDGE_REMOVAL 1 // Skip cartridge removal check #define SKIP_EMPTY_RES_CHECK 1 // Skip reservoir empty check -// #define DISABLE_FPGA_COUNTER_CHECKS 1 // Disable alarms associated with FPGA read/error counters -// #define DISABLE_VOLTAGE_MONITOR 1 // Disable voltage monitoring/alarms + #define DISABLE_FPGA_COUNTER_CHECKS 1 // Disable alarms associated with FPGA read/error counters + #define DISABLE_VOLTAGE_MONITOR 1 // Disable voltage monitoring/alarms #define ALLOW_1_MIN_TREATMENT_DURATION 1 // Allow user to change treatment duration to as low as 1 minute -// #define DISABLE_SYRINGE_PUMP_ALARMS 1 // Disable some syringe pump alarms that are triggering intermittently + #define DISABLE_SYRINGE_PUMP_ALARMS 1 // Disable some syringe pump alarms that are triggering intermittently #include #include