Index: firmware/App/HDCommon.h =================================================================== diff -u -r46617afb446c35270b59e21085b270433d13d113 -r82e9c6f8c12f684f5aca406e93ff31554017eee8 --- firmware/App/HDCommon.h (.../HDCommon.h) (revision 46617afb446c35270b59e21085b270433d13d113) +++ firmware/App/HDCommon.h (.../HDCommon.h) (revision 82e9c6f8c12f684f5aca406e93ff31554017eee8) @@ -1,18 +1,26 @@ /************************************************************************** * -* Copyright (c) 2019-2020 Diality Inc. - All Rights Reserved. +* Copyright (c) 2019-2021 Diality Inc. - All Rights Reserved. * * THIS CODE MAY NOT BE COPIED OR REPRODUCED IN ANY FORM, IN PART OR IN * WHOLE, WITHOUT THE EXPLICIT PERMISSION OF THE COPYRIGHT OWNER. * -* @file HDCommon.h +* @file HDCommon.h * -* @author (last) Sean Nash -* @date (last) 14-Oct-2020 +<<<<<<< HEAD +* @author (last) Sean Nash +* @date (last) 14-Oct-2020 * -* @author (original) Sean -* @date (original) 27-Feb-2020 +* @author (original) Sean +* @date (original) 27-Feb-2020 +======= +* @author (last) Quang Nguyen +* @date (last) 09-Aug-2021 * +* @author (original) Sean +* @date (original) 27-Feb-2020 +>>>>>>> DEN-9480-dialysate-temperature-control +* ***************************************************************************/ #ifndef __HD_COMMON_H__ @@ -25,7 +33,7 @@ #define HD_VERSION_MAJOR 0 #define HD_VERSION_MINOR 6 #define HD_VERSION_MICRO 0 -#define HD_VERSION_BUILD 0 +#define HD_VERSION_BUILD 91 // ********** development build switches ********** @@ -57,8 +65,9 @@ // #define DISABLE_PUMP_DIRECTION_CHECKS 1 // Do not error on HD pump direction checks #define DISABLE_SYRINGE_PUMP 1 // Disable syringe pump functionality #define ALWAYS_ALLOW_SYRINGE_PUMP_CMDS 1 // Allow syringe pump commands at any time except when pump is busy -// #define DISABLE_PRESSURE_CHECKS 1 // Do not error on HD pressure checks -// #define DISABLE_UF_ALARMS 1 // Do not error on HD ultrafiltration checks + #define DISABLE_UF_ALARMS 1 // Do not error on HD ultrafiltration checks + #define DISABLE_DIALYSATE_TEMP_CHECK 1 // Disable dialysate temperature check + #define DISABLE_PRESSURE_CHECKS 1 // Do not error on HD pressure checks #define DISABLE_VALVE_ALARMS 1 // Do not error on HD valve position #define SKIP_CAL_CHECK 1 // // #define RUN_PUMPS_OPEN_LOOP 1 // BP and DPi pumps will be run open loop (no flow sensor feedback) @@ -71,7 +80,7 @@ #define DISABLE_OCCLUSION_SELF_TEST 1 // Skip occlusion sensor self-test. // #define SKIP_CARTRIDGE_REMOVAL 1 // Skip cartridge removal check // #define DISABLE_FPGA_COUNTER_CHECKS 1 // Disable alarms associated with FPGA read/error counters -// #define DISABLE_VOLTAGE_MONITOR 1 // Disable voltage monitoring/alarms + #define DISABLE_VOLTAGE_MONITOR 1 // Disable voltage monitoring/alarms #define ALLOW_1_MIN_TREATMENT_DURATION 1 // Allow user to change treatment duration to as low as 1 minute #define DISABLE_SYRINGE_PUMP_ALARMS 1 // Disable some syringe pump alarms that are triggering intermittently // #define NO_PUMP_FLOW_LIMITS 1 // Allow any commanded flow rate for peristaltic pumps