Index: firmware/App/HDCommon.h =================================================================== diff -u -r494828bba7e66a82f498a0fee6f370e387f99fb9 -rdd1a9a6f5e43a5da27f4d51f56388f7d019cc43d --- firmware/App/HDCommon.h (.../HDCommon.h) (revision 494828bba7e66a82f498a0fee6f370e387f99fb9) +++ firmware/App/HDCommon.h (.../HDCommon.h) (revision dd1a9a6f5e43a5da27f4d51f56388f7d019cc43d) @@ -10,8 +10,8 @@ * @author (last) Dara Navaei * @date (last) 04-Jan-2022 * -* @author (original) Sean -* @date (original) 27-Feb-2020 +* @author (original) Sean +* @date (original) 27-Feb-2020 * ***************************************************************************/ @@ -25,7 +25,7 @@ #define HD_VERSION_MAJOR 0 #define HD_VERSION_MINOR 6 #define HD_VERSION_MICRO 0 -#define HD_VERSION_BUILD 31 +#define HD_VERSION_BUILD 154 // ********** development build switches ********** @@ -49,7 +49,7 @@ // #define RUN_BP_OPEN_LOOP 1 // Run blood pump in open loop mode // #define RUN_DPI_OPEN_LOOP 1 // Run dialysate inlet pump in open loop mode #define WORN_OUT_CARTRIDGE 1 // Running with an old worn out cartridge (max wear) -// #define PBA_ESTIMATION 1 // Estimate arterial pressure rather than look at PBA sensor + #define PBA_ESTIMATION 1 // Estimate arterial pressure rather than look at PBA sensor #define DISABLE_MOTOR_CURRENT_CHECKS 1 // Do not error on HD pump current checks #define DISABLE_PUMP_FLOW_CHECKS 1 // Do not error on HD pump flow checks #define DISABLE_PUMP_SPEED_CHECKS 1 // Do not error on HD pump speed checks @@ -62,8 +62,8 @@ // #define DISABLE_UF_ALARMS 1 // Do not error on HD ultrafiltration checks #define DISABLE_DIALYSATE_TEMP_CHECK 1 // Disable dialysate temperature check -// #define DISABLE_VALVE_ALARMS 1 // Do not error on HD valve position - #define SKIP_CAL_CHECK 1 + #define DISABLE_VALVE_ALARMS 1 // Do not error on HD valve position + #define SKIP_CAL_CHECK 1 // // #define RUN_PUMPS_OPEN_LOOP 1 // BP and DPi pumps will be run open loop (no flow sensor feedback) // #define READ_FPGA_ASYNC_DATA 1 // Test build reads non-priority register page every other time // #define EMC_TEST_BUILD 1 // EMC test build - HD/DG run separately but connected, HD pumps toggle on/off w/ stop button @@ -78,23 +78,25 @@ #define ALLOW_1_MIN_TREATMENT_DURATION 1 // Allow user to change treatment duration to as low as 1 minute // #define DISABLE_SYRINGE_PUMP_ALARMS 1 // Disable some syringe pump alarms that are triggering intermittently // #define NO_PUMP_FLOW_LIMITS 1 // Allow any commanded flow rate for peristaltic pumps -// #define DISABLE_BUBBLE_ALARMS 1 // Disable bubble alarms + #define DISABLE_BUBBLE_ALARMS 1 // Disable bubble alarms #define DISABLE_UI_POST_TEST 1 // Disable the UI POST // #define DISABLE_UI_COMM_TO_ALARM 1 // Disable UI comm timeouts #define DISABLE_WD_AND_SFTY_POST_TESTS 1 // Disable watchdog and safety shutdown POST tests #define DISABLE_ILLEGAL_AIR_TRAP_ALARM 1 // Disable illegal state for air trap alarm #define SKIP_RESERVOIR_ALARMS 1 // Skip reservoir management alarms - #define IGNORE_BLOOD_LEAK_SELF_TEST 1 // Ignore blood leak self test +// #define SKIP_RESERVOIR_ALARMS 1 // Skip reservoir management alarms +// #define IGNORE_BLOOD_LEAK_SELF_TEST 1 // Ignore blood leak self test #define IGNORE_BLOOD_LEAK_ALARM 1 // Ignore blood leak alarm // Skip Pre-Treatment and get to treatment as soon as possible -// #define SKIP_UI_INTERACTION 1 // Skip UI interaction. + #define SKIP_UI_INTERACTION 1 // Skip UI interaction. #define SKIP_SAMPLE_WATER 1 // Skip pre-treatment sample water #define SKIP_CONSUMABLE_TESTS 1 // Skip pre-treatment consumable Self-tests #define SKIP_DRY_SELF_TESTS 1 // Skip pre-treatment dry self-tests -// #define SKIP_PRIMING 1 // Skip Pre-treatment Prime -// #define SKIP_WET_SELF_TESTS 1 // Skip Pre-treatment prime wet self-tests + #define SKIP_PRIMING 1 // Skip Pre-treatment Prime + #define SKIP_WET_SELF_TESTS 1 // Skip Pre-treatment prime wet self-tests + #include #include #endif