Index: firmware/App/HDCommon.h =================================================================== diff -u -r563f516a81cb41290008f93b33e7cf5e121717db -rc05775820109b5e83596c58a3b4248ac6cdb1d65 --- firmware/App/HDCommon.h (.../HDCommon.h) (revision 563f516a81cb41290008f93b33e7cf5e121717db) +++ firmware/App/HDCommon.h (.../HDCommon.h) (revision c05775820109b5e83596c58a3b4248ac6cdb1d65) @@ -43,18 +43,18 @@ #define DISABLE_AIR_TRAP_LEVELING_ALARM 1 // Disable air trap level control alarms // #define DISABLE_3WAY_VALVES 1 // Disable 3-way valves // #define TST_3WAY_VALVES_ALWAYS_OPEN 1 // After POST and homing, open all 4 valves - #define DISABLE_ACCELS 1 // Disable accelerometer POST and monitoring +// #define DISABLE_ACCELS 1 // Disable accelerometer POST and monitoring // #define DISABLE_CRC_ERROR 1 // Do not error on bad CRC for CAN messages // #define DISABLE_ACK_ERRORS 1 // Do not error on failure of other node(s) to ACK a message - #define DISABLE_MOTOR_CURRENT_CHECKS 1 // Do not error on HD pump current checks - #define DISABLE_PUMP_FLOW_CHECKS 1 // Do not error on HD pump flow checks - #define DISABLE_PUMP_SPEED_CHECKS 1 // Do not error on HD pump speed checks - #define DISABLE_PUMP_DIRECTION_CHECKS 1 // Do not error on HD pump direction checks +// #define DISABLE_MOTOR_CURRENT_CHECKS 1 // Do not error on HD pump current checks +// #define DISABLE_PUMP_FLOW_CHECKS 1 // Do not error on HD pump flow checks +// #define DISABLE_PUMP_SPEED_CHECKS 1 // Do not error on HD pump speed checks +// #define DISABLE_PUMP_DIRECTION_CHECKS 1 // Do not error on HD pump direction checks // #define DISABLE_SYRINGE_PUMP 1 // Disable syringe pump functionality #define ALWAYS_ALLOW_SYRINGE_PUMP_CMDS 1 // Allow syringe pump commands at any time except when pump is busy - #define DISABLE_PRESSURE_CHECKS 1 // Do not error on HD pressure checks +// #define DISABLE_PRESSURE_CHECKS 1 // Do not error on HD pressure checks // #define DISABLE_UF_ALARMS 1 // Do not error on HD ultrafiltration checks - #define DISABLE_VALVE_ALARMS 1 // Do not error on HD valve position +// #define DISABLE_VALVE_ALARMS 1 // Do not error on HD valve position #define DISABLE_CAL_CHECK 1 // Disable calibration checks // #define RUN_PUMPS_OPEN_LOOP 1 // BP and DPi pumps will be run open loop (no flow sensor feedback) // #define RAW_FLOW_SENSOR_DATA 1 // Test build will not filter flow sensor data @@ -73,10 +73,10 @@ // #define DISABLE_BATT_COMM 1 // Disable battery communication. #define SKIP_AIR_BUBBLE_CHECK 1 // Skip air bubble detector self-test. #define DISABLE_OCCLUSION_SELF_TEST 1 // Skip occlusion sensor self-test. - #define DISABLE_FPGA_COUNTER_CHECKS 1 // Disable alarms associated with FPGA read/error counters - #define DISABLE_VOLTAGE_MONITOR 1 // Disable voltage monitoring/alarms +// #define DISABLE_FPGA_COUNTER_CHECKS 1 // Disable alarms associated with FPGA read/error counters +// #define DISABLE_VOLTAGE_MONITOR 1 // Disable voltage monitoring/alarms #define ALLOW_1_MIN_TREATMENT_DURATION 1 // Allow user to change treatment duration to as low as 1 minute - #define DISABLE_SYRINGE_PUMP_ALARMS 1 // Disable some syringe pump alarms that are triggering intermittently +// #define DISABLE_SYRINGE_PUMP_ALARMS 1 // Disable some syringe pump alarms that are triggering intermittently #include #include