Index: firmware/App/HDCommon.h =================================================================== diff -u -r6c34ce9c95ba654ebb9f880bf35b7e8c594184f1 -r29cb4f24819fd6590283fd5312bd373c6f0b7bd8 --- firmware/App/HDCommon.h (.../HDCommon.h) (revision 6c34ce9c95ba654ebb9f880bf35b7e8c594184f1) +++ firmware/App/HDCommon.h (.../HDCommon.h) (revision 29cb4f24819fd6590283fd5312bd373c6f0b7bd8) @@ -43,18 +43,18 @@ #define DISABLE_AIR_TRAP_LEVELING 1 // Disable air trap level control // #define DISABLE_3WAY_VALVES 1 // Disable 3-way valves // #define TST_3WAY_VALVES_ALWAYS_OPEN 1 // After POST and homing, open all 4 valves -// #define DISABLE_ACCELS 1 // Disable accelerometer POST and monitoring + #define DISABLE_ACCELS 1 // Disable accelerometer POST and monitoring // #define DISABLE_CRC_ERROR 1 // Do not error on bad CRC for CAN messages // #define DISABLE_ACK_ERRORS 1 // Do not error on failure of other node(s) to ACK a message #define DISABLE_MOTOR_CURRENT_CHECKS 1 // Do not error on HD pump current checks #define DISABLE_PUMP_FLOW_CHECKS 1 // Do not error on HD pump flow checks #define DISABLE_PUMP_SPEED_CHECKS 1 // Do not error on HD pump speed checks #define DISABLE_PUMP_DIRECTION_CHECKS 1 // Do not error on HD pump direction checks -// #define DISABLE_SYRINGE_PUMP 1 // Disable syringe pump functionality + #define DISABLE_SYRINGE_PUMP 1 // Disable syringe pump functionality #define ALWAYS_ALLOW_SYRINGE_PUMP_CMDS 1 // Allow syringe pump commands at any time except when pump is busy #define DISABLE_PRESSURE_CHECKS 1 // Do not error on HD pressure checks // #define DISABLE_UF_ALARMS 1 // Do not error on HD ultrafiltration checks - #define DISABLE_VALVE_ALARMS 1 // Do not error on HD valve position +// #define DISABLE_VALVE_ALARMS 1 // Do not error on HD valve position #define DISABLE_CAL_CHECK 1 // Disable calibration checks // #define RUN_PUMPS_OPEN_LOOP 1 // BP and DPi pumps will be run open loop (no flow sensor feedback) // #define RAW_FLOW_SENSOR_DATA 1 // Test build will not filter flow sensor data @@ -66,7 +66,7 @@ #define SKIP_PRIMING 1 // Skip Pre-treatment Prime #define SKIP_WET_SELF_TESTS 1 // Skip Pre-treatment prime wet self-tests // #define V1_5_SYSTEM 1 // Build for v1.5 system -// #define V2_0_SYSTEM 1 // Build for v2.0 system + #define V2_0_SYSTEM 1 // Build for v2.0 system // #define SKIP_SAMPLE_WATER 1 // Skip pre-treatment sample water #define SKIP_CONSUMABLE_TESTS 1 // Skip pre-treatment consumable Self-tests #define SKIP_DRY_SELF_TESTS 1 // Skip pre-treatment dry self-tests @@ -77,8 +77,6 @@ // #define SKIP_CARTRIDGE_REMOVAL 1 // Skip cartridge removal check #define SKIP_EMPTY_RES_CHECK 1 // Skip reservoir empty check #define DISABLE_FPGA_COUNTER_CHECKS 1 // Disable alarms associated with FPGA read/error counters - #define DISABLE_VOLTAGE_MONITOR 1 // Disable voltage monitoring/alarms - #define ALLOW_1_MIN_TREATMENT_DURATION 1 // Allow user to change treatment duration to as low as 1 minute #include