Index: firmware/App/HDCommon.h =================================================================== diff -u -r7de1ffc01a8b979c8e9c1bb9020a768ab62f0320 -r2c162a8b414b9eeb48ac7bbbcfc1671cf4b21b01 --- firmware/App/HDCommon.h (.../HDCommon.h) (revision 7de1ffc01a8b979c8e9c1bb9020a768ab62f0320) +++ firmware/App/HDCommon.h (.../HDCommon.h) (revision 2c162a8b414b9eeb48ac7bbbcfc1671cf4b21b01) @@ -1,17 +1,17 @@ /************************************************************************** * -* Copyright (c) 2019-2020 Diality Inc. - All Rights Reserved. +* Copyright (c) 2019-2021 Diality Inc. - All Rights Reserved. * * THIS CODE MAY NOT BE COPIED OR REPRODUCED IN ANY FORM, IN PART OR IN * WHOLE, WITHOUT THE EXPLICIT PERMISSION OF THE COPYRIGHT OWNER. * -* @file HDCommon.h +* @file HDCommon.h * -* @author (last) Sean Nash -* @date (last) 14-Oct-2020 +* @author (last) Sean Nash +* @date (last) 14-Oct-2020 * -* @author (original) Sean -* @date (original) 27-Feb-2020 +* @author (original) Sean +* @date (original) 27-Feb-2020 * ***************************************************************************/ @@ -25,7 +25,7 @@ #define HD_VERSION_MAJOR 0 #define HD_VERSION_MINOR 6 #define HD_VERSION_MICRO 0 -#define HD_VERSION_BUILD 0 +#define HD_VERSION_BUILD 107 // ********** development build switches ********** @@ -50,15 +50,16 @@ // #define RUN_BP_OPEN_LOOP 1 // Run blood pump in open loop mode // #define RUN_DPI_OPEN_LOOP 1 // Run dialysate inlet pump in open loop mode #define WORN_OUT_CARTRIDGE 1 // Running with an old worn out cartridge (max wear) - #define PBA_ESTIMATION 1 // Estimate arterial pressure rather than look at PBA sensor +// #define PBA_ESTIMATION 1 // Estimate arterial pressure rather than look at PBA sensor #define DISABLE_MOTOR_CURRENT_CHECKS 1 // Do not error on HD pump current checks #define DISABLE_PUMP_FLOW_CHECKS 1 // Do not error on HD pump flow checks #define DISABLE_PUMP_SPEED_CHECKS 1 // Do not error on HD pump speed checks #define DISABLE_PUMP_DIRECTION_CHECKS 1 // Do not error on HD pump direction checks - #define DISABLE_SYRINGE_PUMP 1 // Disable syringe pump functionality +// #define DISABLE_SYRINGE_PUMP 1 // Disable syringe pump functionality #define ALWAYS_ALLOW_SYRINGE_PUMP_CMDS 1 // Allow syringe pump commands at any time except when pump is busy -// #define DISABLE_PRESSURE_CHECKS 1 // Do not error on HD pressure checks -// #define DISABLE_UF_ALARMS 1 // Do not error on HD ultrafiltration checks + #define DISABLE_UF_ALARMS 1 // Do not error on HD ultrafiltration checks + #define DISABLE_DIALYSATE_TEMP_CHECK 1 // Disable dialysate temperature check + #define DISABLE_PRESSURE_CHECKS 1 // Do not error on HD pressure checks #define DISABLE_VALVE_ALARMS 1 // Do not error on HD valve position #define SKIP_CAL_CHECK 1 // // #define RUN_PUMPS_OPEN_LOOP 1 // BP and DPi pumps will be run open loop (no flow sensor feedback) @@ -71,11 +72,11 @@ #define DISABLE_OCCLUSION_SELF_TEST 1 // Skip occlusion sensor self-test. // #define SKIP_CARTRIDGE_REMOVAL 1 // Skip cartridge removal check // #define DISABLE_FPGA_COUNTER_CHECKS 1 // Disable alarms associated with FPGA read/error counters -// #define DISABLE_VOLTAGE_MONITOR 1 // Disable voltage monitoring/alarms + #define DISABLE_VOLTAGE_MONITOR 1 // Disable voltage monitoring/alarms #define ALLOW_1_MIN_TREATMENT_DURATION 1 // Allow user to change treatment duration to as low as 1 minute - #define DISABLE_SYRINGE_PUMP_ALARMS 1 // Disable some syringe pump alarms that are triggering intermittently +// #define DISABLE_SYRINGE_PUMP_ALARMS 1 // Disable some syringe pump alarms that are triggering intermittently // #define NO_PUMP_FLOW_LIMITS 1 // Allow any commanded flow rate for peristaltic pumps -// #define DISABLE_BUBBLE_ALARMS 1 // Disable bubble alarms + #define DISABLE_BUBBLE_ALARMS 1 // Disable bubble alarms #define DISABLE_UI_POST_TEST 1 // Disable the UI POST // #define DISABLE_UI_COMM_TO_ALARM 1 // Disable UI comm timeouts