Index: firmware/App/HDCommon.h =================================================================== diff -u -r8acad167bcf7ad07043192007e59d253a5216e3a -rafa9d4924d55ac4fc98270a012e92dd1f6ee65d0 --- firmware/App/HDCommon.h (.../HDCommon.h) (revision 8acad167bcf7ad07043192007e59d253a5216e3a) +++ firmware/App/HDCommon.h (.../HDCommon.h) (revision afa9d4924d55ac4fc98270a012e92dd1f6ee65d0) @@ -47,15 +47,15 @@ // #define DISABLE_ACCELS 1 // Disable accelerometer POST and monitoring // #define DISABLE_CRC_ERROR 1 // Do not error on bad CRC for CAN messages // #define DISABLE_ACK_ERRORS 1 // Do not error on failure of other node(s) to ACK a message -// #define DISABLE_MOTOR_CURRENT_CHECKS 1 // Do not error on HD pump current checks -// #define DISABLE_PUMP_FLOW_CHECKS 1 // Do not error on HD pump flow checks -// #define DISABLE_PUMP_SPEED_CHECKS 1 // Do not error on HD pump speed checks -// #define DISABLE_PUMP_DIRECTION_CHECKS 1 // Do not error on HD pump direction checks + #define DISABLE_MOTOR_CURRENT_CHECKS 1 // Do not error on HD pump current checks + #define DISABLE_PUMP_FLOW_CHECKS 1 // Do not error on HD pump flow checks + #define DISABLE_PUMP_SPEED_CHECKS 1 // Do not error on HD pump speed checks + #define DISABLE_PUMP_DIRECTION_CHECKS 1 // Do not error on HD pump direction checks #define DISABLE_SYRINGE_PUMP 1 // Disable syringe pump functionality #define ALWAYS_ALLOW_SYRINGE_PUMP_CMDS 1 // Allow syringe pump commands at any time except when pump is busy #define DISABLE_PRESSURE_CHECKS 1 // Do not error on HD pressure checks // #define DISABLE_UF_ALARMS 1 // Do not error on HD ultrafiltration checks -// #define DISABLE_VALVE_ALARMS 1 // Do not error on HD valve position + #define DISABLE_VALVE_ALARMS 1 // Do not error on HD valve position #define DISABLE_CAL_CHECK 1 // Disable calibration checks #define DISABLE_DIALYSATE_TEMP_CHECK 1 // Disable dialysate temperature check // #define RUN_PUMPS_OPEN_LOOP 1 // BP and DPi pumps will be run open loop (no flow sensor feedback) @@ -64,7 +64,7 @@ // #define EMC_TEST_BUILD 1 // EMC test build - HD/DG run separately but connected, HD pumps toggle on/off w/ stop button #define ALARMS_DEBUG 1 // Triggered alarms sent to debug UART #define ALARM_VOLUME_DEFAULT_LOW 1 // Set default alarm volume to lowest - #define TEMP_UI_ALARM_SILENCE_FIX 1 // Temporary UI fix for handling alarm silence request msg +// #define TEMP_UI_ALARM_SILENCE_FIX 1 // Temporary UI fix for handling alarm silence request msg // #define V2_0_SYSTEM 1 // Build for v2.0 system #define DISABLE_BATT_COMM 1 // Disable battery communication. #define SKIP_AIR_BUBBLE_CHECK 1 // Skip air bubble detector self-test. @@ -73,7 +73,10 @@ // #define DISABLE_FPGA_COUNTER_CHECKS 1 // Disable alarms associated with FPGA read/error counters // #define DISABLE_VOLTAGE_MONITOR 1 // Disable voltage monitoring/alarms #define ALLOW_1_MIN_TREATMENT_DURATION 1 // Allow user to change treatment duration to as low as 1 minute -// #define DISABLE_SYRINGE_PUMP_ALARMS 1 // Disable some syringe pump alarms that are triggering intermittently + #define DISABLE_SYRINGE_PUMP_ALARMS 1 // Disable some syringe pump alarms that are triggering intermittently +// #define NO_PUMP_FLOW_LIMITS 1 // Allow any commanded flow rate for peristaltic pumps + #define DISABLE_BUBBLE_ALARMS 1 // Disable bubble alarms + #define DISABLE_UI_POST_TEST 1 // Disable the UI POST // Skip Pre-Treatment and get to treatment as soon as possible // #define SKIP_UI_INTERACTION 1 // Skip UI interaction.