Index: firmware/App/HDCommon.h =================================================================== diff -u -r8e7117edb515a425c21ba1a091d5f260252cc7f0 -r1ebbe403d260d9f65695c13d6dbafbe1a93cfdde --- firmware/App/HDCommon.h (.../HDCommon.h) (revision 8e7117edb515a425c21ba1a091d5f260252cc7f0) +++ firmware/App/HDCommon.h (.../HDCommon.h) (revision 1ebbe403d260d9f65695c13d6dbafbe1a93cfdde) @@ -40,7 +40,6 @@ #define DISABLE_ALARM_AUDIO 1 // Disable alarm audio // #define SKIP_POST 1 // Skip POST tests - all pass // #define DONT_SKIP_NV_POST 1 // Do not skip NV Data POST -// #define USE_LIBRARY_TIME_FUNCTIONS 1 // Use the C library functions mktime() and gmtime() for epoch<=>date conversions #define DISABLE_AIR_TRAP_LEVELING_ALARM 1 // Disable air trap level control alarms // #define DISABLE_3WAY_VALVES 1 // Disable 3-way valves // #define TST_3WAY_VALVES_ALWAYS_OPEN 1 // After POST and homing, open all 4 valves @@ -49,15 +48,17 @@ #define DISABLE_ACK_ERRORS 1 // Do not error on failure of other node(s) to ACK a message #define DISABLE_MOTOR_CURRENT_CHECKS 1 // Do not error on HD pump current checks #define DISABLE_PUMP_FLOW_CHECKS 1 // Do not error on HD pump flow checks -// #define DISABLE_PUMP_SPEED_CHECKS 1 // Do not error on HD pump speed checks + #define ENABLE_ALTERNATE_FLOW 1 // Enable calculation of speed/pressure based flow and publish in lieu of MC motor speed + #define DISABLE_PUMP_SPEED_CHECKS 1 // Do not error on HD pump speed checks // #define DISABLE_PUMP_DIRECTION_CHECKS 1 // Do not error on HD pump direction checks #define DISABLE_SYRINGE_PUMP 1 // Disable syringe pump functionality #define ALWAYS_ALLOW_SYRINGE_PUMP_CMDS 1 // Allow syringe pump commands at any time except when pump is busy #define DISABLE_PRESSURE_CHECKS 1 // Do not error on HD pressure checks // #define DISABLE_UF_ALARMS 1 // Do not error on HD ultrafiltration checks #define DISABLE_DIALYSATE_TEMP_CHECK 1 // Disable dialysate temperature check #define DISABLE_VALVE_ALARMS 1 // Do not error on HD valve position - #define SKIP_CAL_CHECK 1 + #define DISABLE_VALVE_ALARMS 1 // Do not error on HD valve position + #define SKIP_CAL_CHECK 1 // // #define RUN_PUMPS_OPEN_LOOP 1 // BP and DPi pumps will be run open loop (no flow sensor feedback) // #define RAW_FLOW_SENSOR_DATA 1 // Test build will not filter flow sensor data // #define READ_FPGA_ASYNC_DATA 1 // Test build reads non-priority register page every other time @@ -77,7 +78,7 @@ #define DISABLE_UI_POST_TEST 1 // Disable the UI POST // Skip Pre-Treatment and get to treatment as soon as possible -// #define SKIP_UI_INTERACTION 1 // Skip UI interaction. + #define SKIP_UI_INTERACTION 1 // Skip UI interaction. #define SKIP_SAMPLE_WATER 1 // Skip pre-treatment sample water #define SKIP_CONSUMABLE_TESTS 1 // Skip pre-treatment consumable Self-tests #define SKIP_DRY_SELF_TESTS 1 // Skip pre-treatment dry self-tests