Index: firmware/App/HDCommon.h =================================================================== diff -u -r8f799f87cfdc5ecfb74ea6a55b5493512767214f -r5577d7fcbf40b3e188174328143369c84c2e68b1 --- firmware/App/HDCommon.h (.../HDCommon.h) (revision 8f799f87cfdc5ecfb74ea6a55b5493512767214f) +++ firmware/App/HDCommon.h (.../HDCommon.h) (revision 5577d7fcbf40b3e188174328143369c84c2e68b1) @@ -63,26 +63,27 @@ // #define EMC_TEST_BUILD 1 // EMC test build - HD/DG run separately but connected, HD pumps toggle on/off w/ stop button #define ALARMS_DEBUG 1 // Triggered alarms sent to debug UART #define ALARM_VOLUME_DEFAULT_LOW 1 // Set default alarm volume to lowest -// #define TEMP_UI_ALARM_SILENCE_FIX 1 // Temporary UI fix for handling alarm silence request msg - #define SKIP_PRIMING 1 // Skip Pre-treatment Prime - #define SKIP_WET_SELF_TESTS 1 // Skip Pre-treatment prime wet self-tests + #define TEMP_UI_ALARM_SILENCE_FIX 1 // Temporary UI fix for handling alarm silence request msg // #define V2_0_SYSTEM 1 // Build for v2.0 system - #define SKIP_SAMPLE_WATER 1 // Skip pre-treatment sample water - #define SKIP_CONSUMABLE_TESTS 1 // Skip pre-treatment consumable Self-tests - #define SKIP_DRY_SELF_TESTS 1 // Skip pre-treatment dry self-tests -// #define SKIP_UI_INTERACTION 1 // Skip UI interaction. #define DISABLE_BATT_COMM 1 // Disable battery communication. #define SKIP_AIR_BUBBLE_CHECK 1 // Skip air bubble detector self-test. #define DISABLE_OCCLUSION_SELF_TEST 1 // Skip occlusion sensor self-test. // #define SKIP_CARTRIDGE_REMOVAL 1 // Skip cartridge removal check -// #define SKIP_EMPTY_RES_CHECK 1 // Skip reservoir empty check #define DISABLE_FPGA_COUNTER_CHECKS 1 // Disable alarms associated with FPGA read/error counters #define DISABLE_VOLTAGE_MONITOR 1 // Disable voltage monitoring/alarms #define ALLOW_1_MIN_TREATMENT_DURATION 1 // Allow user to change treatment duration to as low as 1 minute #define DISABLE_SYRINGE_PUMP_ALARMS 1 // Disable some syringe pump alarms that are triggering intermittently #define NO_PUMP_FLOW_LIMITS 1 // Allow any commanded flow rate for peristaltic pumps #define DISABLE_BUBBLE_ALARMS 1 // Disable bubble alarms + // Skip Pre-Treatment and get to treatment as soon as possible +// #define SKIP_UI_INTERACTION 1 // Skip UI interaction. + #define SKIP_SAMPLE_WATER 1 // Skip pre-treatment sample water + #define SKIP_CONSUMABLE_TESTS 1 // Skip pre-treatment consumable Self-tests + #define SKIP_DRY_SELF_TESTS 1 // Skip pre-treatment dry self-tests + #define SKIP_PRIMING 1 // Skip Pre-treatment Prime + #define SKIP_WET_SELF_TESTS 1 // Skip Pre-treatment prime wet self-tests + #include #include #endif