Index: firmware/App/HDCommon.h =================================================================== diff -u -ra4198d6a6d52cedcf24cd9260067d5632e94c20f -r0cc09b5d47c4018e6bfa8fb5f5c1a5d341512106 --- firmware/App/HDCommon.h (.../HDCommon.h) (revision a4198d6a6d52cedcf24cd9260067d5632e94c20f) +++ firmware/App/HDCommon.h (.../HDCommon.h) (revision 0cc09b5d47c4018e6bfa8fb5f5c1a5d341512106) @@ -10,8 +10,8 @@ * @author (last) Dara Navaei * @date (last) 04-Jan-2022 * -* @author (original) Sean -* @date (original) 27-Feb-2020 +* @author (original) Sean +* @date (original) 27-Feb-2020 * ***************************************************************************/ @@ -25,7 +25,7 @@ #define HD_VERSION_MAJOR 0 #define HD_VERSION_MINOR 6 #define HD_VERSION_MICRO 0 -#define HD_VERSION_BUILD 31 +#define HD_VERSION_BUILD 205 // ********** development build switches ********** @@ -37,6 +37,7 @@ // #define RUN_WITHOUT_DG 1 // Run HD w/o DG // #define SIMULATE_UI 1 // Build w/o requirement that UI be there // #define TASK_TIMING_OUTPUT_ENABLED 1 // Re-purposes alarm lamp pins for task timing + // TODO convert the new configuration way #define DISABLE_ALARM_AUDIO 1 // Disable alarm audio // #define SKIP_POST 1 // Skip POST tests - all pass // #define DONT_SKIP_NV_POST 1 // Do not skip NV Data POST @@ -54,16 +55,17 @@ // #define DISABLE_PUMP_FLOW_CHECKS 1 // Do not error on HD pump flow checks // #define DISABLE_PUMP_SPEED_CHECKS 1 // Do not error on HD pump speed checks // #define DISABLE_PUMP_DIRECTION_CHECKS 1 // Do not error on HD pump direction checks - #define DISABLE_SYRINGE_PUMP 1 // Disable syringe pump functionality +// #define DISABLE_SYRINGE_PUMP 1 // Disable syringe pump functionality #define ALWAYS_ALLOW_SYRINGE_PUMP_CMDS 1 // Allow syringe pump commands at any time except when pump is busy #define DISABLE_PRESSURE_CHECKS 1 // Do not error on HD pressure checks #define DISABLE_ARTERIAL_PRESSURE_CHECK 1 // Do not error on arterial pressure out of range #define DISABLE_VENOUS_PRESSURE_CHECK 1 // Do not error on venous pressure out of range +// #define USE_PBO_AS_PBA 1 // PBo readings used for PBA, PBo replaced with fixed pressure (100 mmHg) // #define DISABLE_UF_ALARMS 1 // Do not error on HD ultrafiltration checks #define DISABLE_DIALYSATE_TEMP_CHECK 1 // Disable dialysate temperature check // #define DISABLE_VALVE_ALARMS 1 // Do not error on HD valve position - #define SKIP_CAL_CHECK 1 + #define SKIP_CAL_CHECK 1 // // #define RUN_PUMPS_OPEN_LOOP 1 // BP and DPi pumps will be run open loop (no flow sensor feedback) // #define READ_FPGA_ASYNC_DATA 1 // Test build reads non-priority register page every other time // #define EMC_TEST_BUILD 1 // EMC test build - HD/DG run separately but connected, HD pumps toggle on/off w/ stop button @@ -76,23 +78,24 @@ // #define DISABLE_FPGA_COUNTER_CHECKS 1 // Disable alarms associated with FPGA read/error counters #define DISABLE_VOLTAGE_MONITOR 1 // Disable voltage monitoring/alarms #define ALLOW_1_MIN_TREATMENT_DURATION 1 // Allow user to change treatment duration to as low as 1 minute - #define DISABLE_SYRINGE_PUMP_ALARMS 1 // Disable some syringe pump alarms that are triggering intermittently -// #define NO_PUMP_FLOW_LIMITS 1 // Allow any commanded flow rate for peristaltic pumps -// #define DISABLE_BUBBLE_ALARMS 1 // Disable bubble alarms +// #define DISABLE_SYRINGE_PUMP_ALARMS 1 // Disable some syringe pump alarms that are triggering intermittently + #define NO_PUMP_FLOW_LIMITS 1 // Allow any commanded flow rate for peristaltic pumps + #define DISABLE_BUBBLE_ALARMS 1 // Disable bubble alarms #define DISABLE_UI_POST_TEST 1 // Disable the UI POST // #define DISABLE_UI_COMM_TO_ALARM 1 // Disable UI comm timeouts #define DISABLE_WD_AND_SFTY_POST_TESTS 1 // Disable watchdog and safety shutdown POST tests #define DISABLE_ILLEGAL_AIR_TRAP_ALARM 1 // Disable illegal state for air trap alarm #define SKIP_RESERVOIR_ALARMS 1 // Skip reservoir management alarms - #define IGNORE_BLOOD_LEAK_SELF_TEST 1 // Ignore blood leak self test - #define IGNORE_BLOOD_LEAK_ALARM 1 // Ignore blood leak alarm + // #define IGNORE_BLOOD_LEAK_SELF_TEST 1 // Ignore blood leak self test // TODO New config implemented +// #define IGNORE_BLOOD_LEAK_ALARM 1 // Ignore blood leak alarm // TODO New config implemented +// #define DISABLE_SERVICE_RECORD 1 // Skip Pre-Treatment and get to treatment as soon as possible -// #define SKIP_UI_INTERACTION 1 // Skip UI interaction. - #define SKIP_SAMPLE_WATER 1 // Skip pre-treatment sample water - #define SKIP_CONSUMABLE_TESTS 1 // Skip pre-treatment consumable Self-tests + #define SKIP_UI_INTERACTION 1 // Skip UI interaction. // TODO New config implemented + #define SKIP_SAMPLE_WATER 1 // Skip pre-treatment sample water // TODO New config implemented + #define SKIP_CONSUMABLE_TESTS 1 // Skip pre-treatment consumable Self-tests // TODO New config implemented #define SKIP_DRY_SELF_TESTS 1 // Skip pre-treatment dry self-tests -// #define SKIP_PRIMING 1 // Skip Pre-treatment Prime + #define SKIP_PRIMING 1 // Skip Pre-treatment Prime // #define SKIP_WET_SELF_TESTS 1 // Skip Pre-treatment prime wet self-tests #include