Index: firmware/App/HDCommon.h =================================================================== diff -u -rbaa9fb9bb10eed6cd211abaa80e9f9acffdeb20d -rafa9d4924d55ac4fc98270a012e92dd1f6ee65d0 --- firmware/App/HDCommon.h (.../HDCommon.h) (revision baa9fb9bb10eed6cd211abaa80e9f9acffdeb20d) +++ firmware/App/HDCommon.h (.../HDCommon.h) (revision afa9d4924d55ac4fc98270a012e92dd1f6ee65d0) @@ -23,7 +23,7 @@ // ********** version ********** #define HD_VERSION_MAJOR 0 -#define HD_VERSION_MINOR 5 +#define HD_VERSION_MINOR 6 #define HD_VERSION_MICRO 0 #define HD_VERSION_BUILD 9037 @@ -37,9 +37,9 @@ // #define RUN_WITHOUT_DG 1 // Run HD w/o DG // #define SIMULATE_UI 1 // Build w/o requirement that UI be there // #define TASK_TIMING_OUTPUT_ENABLED 1 // Re-purposes alarm lamp pins for task timing -// #define DISABLE_ALARM_AUDIO 1 // Disable alarm audio -// #define SKIP_POST 1 // Skip POST tests - all pass -// #define DONT_SKIP_NV_POST 1 // Do not skip NV Data POST + #define DISABLE_ALARM_AUDIO 1 // Disable alarm audio + #define SKIP_POST 1 // Skip POST tests - all pass + #define DONT_SKIP_NV_POST 1 // Do not skip NV Data POST // #define USE_LIBRARY_TIME_FUNCTIONS 1 // Use the C library functions mktime() and gmtime() for epoch<=>date conversions #define DISABLE_AIR_TRAP_LEVELING_ALARM 1 // Disable air trap level control alarms // #define DISABLE_3WAY_VALVES 1 // Disable 3-way valves @@ -57,25 +57,19 @@ // #define DISABLE_UF_ALARMS 1 // Do not error on HD ultrafiltration checks #define DISABLE_VALVE_ALARMS 1 // Do not error on HD valve position #define DISABLE_CAL_CHECK 1 // Disable calibration checks + #define DISABLE_DIALYSATE_TEMP_CHECK 1 // Disable dialysate temperature check // #define RUN_PUMPS_OPEN_LOOP 1 // BP and DPi pumps will be run open loop (no flow sensor feedback) // #define RAW_FLOW_SENSOR_DATA 1 // Test build will not filter flow sensor data // #define READ_FPGA_ASYNC_DATA 1 // Test build reads non-priority register page every other time // #define EMC_TEST_BUILD 1 // EMC test build - HD/DG run separately but connected, HD pumps toggle on/off w/ stop button #define ALARMS_DEBUG 1 // Triggered alarms sent to debug UART #define ALARM_VOLUME_DEFAULT_LOW 1 // Set default alarm volume to lowest // #define TEMP_UI_ALARM_SILENCE_FIX 1 // Temporary UI fix for handling alarm silence request msg - #define SKIP_PRIMING 1 // Skip Pre-treatment Prime - #define SKIP_WET_SELF_TESTS 1 // Skip Pre-treatment prime wet self-tests // #define V2_0_SYSTEM 1 // Build for v2.0 system - #define SKIP_SAMPLE_WATER 1 // Skip pre-treatment sample water - #define SKIP_CONSUMABLE_TESTS 1 // Skip pre-treatment consumable Self-tests - #define SKIP_DRY_SELF_TESTS 1 // Skip pre-treatment dry self-tests - #define SKIP_UI_INTERACTION 1 // Skip UI interaction. -// #define DISABLE_BATT_COMM 1 // Disable battery communication. + #define DISABLE_BATT_COMM 1 // Disable battery communication. #define SKIP_AIR_BUBBLE_CHECK 1 // Skip air bubble detector self-test. #define DISABLE_OCCLUSION_SELF_TEST 1 // Skip occlusion sensor self-test. // #define SKIP_CARTRIDGE_REMOVAL 1 // Skip cartridge removal check - #define SKIP_EMPTY_RES_CHECK 1 // Skip reservoir empty check // #define DISABLE_FPGA_COUNTER_CHECKS 1 // Disable alarms associated with FPGA read/error counters // #define DISABLE_VOLTAGE_MONITOR 1 // Disable voltage monitoring/alarms #define ALLOW_1_MIN_TREATMENT_DURATION 1 // Allow user to change treatment duration to as low as 1 minute @@ -84,6 +78,14 @@ #define DISABLE_BUBBLE_ALARMS 1 // Disable bubble alarms #define DISABLE_UI_POST_TEST 1 // Disable the UI POST + // Skip Pre-Treatment and get to treatment as soon as possible +// #define SKIP_UI_INTERACTION 1 // Skip UI interaction. + #define SKIP_SAMPLE_WATER 1 // Skip pre-treatment sample water + #define SKIP_CONSUMABLE_TESTS 1 // Skip pre-treatment consumable Self-tests + #define SKIP_DRY_SELF_TESTS 1 // Skip pre-treatment dry self-tests + #define SKIP_PRIMING 1 // Skip Pre-treatment Prime + #define SKIP_WET_SELF_TESTS 1 // Skip Pre-treatment prime wet self-tests + #include #include #endif