Index: firmware/App/HDCommon.h =================================================================== diff -u -rd33ae635eb38ae8f2647f68304be74e8e4f78cfd -r667feab319b14681a0330a715da7a1ba930b518d --- firmware/App/HDCommon.h (.../HDCommon.h) (revision d33ae635eb38ae8f2647f68304be74e8e4f78cfd) +++ firmware/App/HDCommon.h (.../HDCommon.h) (revision 667feab319b14681a0330a715da7a1ba930b518d) @@ -38,27 +38,14 @@ // #define SIMULATE_UI 1 // Build w/o requirement that UI be there // #define TASK_TIMING_OUTPUT_ENABLED 1 // Re-purposes alarm lamp pins for task timing // TODO convert the new configuration way -// #define DISABLE_ALARM_AUDIO 1 // Disable alarm audio // TODo sw config implemented -// #define SKIP_POST 1 // Skip POST tests - all pass // TODO remove this -// #define DISABLE_AIR_TRAP_LEVELING_ALARM 1 // Disable air trap level control alarms // TODO sw config implemented // #define DISABLE_3WAY_VALVES 1 // Disable 3-way valves // #define TST_3WAY_VALVES_ALWAYS_OPEN 1 // After POST and homing, open all 4 valves // #define DISABLE_ACCELS 1 // Disable accelerometer POST and monitoring // #define DISABLE_CRC_ERROR 1 // Do not error on bad CRC for CAN messages // #define DISABLE_ACK_ERRORS 1 // Do not error on failure of other node(s) to ACK a message // TODO sw config implemented // #define RUN_BP_OPEN_LOOP 1 // Run blood pump in open loop mode // #define RUN_DPI_OPEN_LOOP 1 // Run dialysate inlet pump in open loop mode -// #define WORN_OUT_CARTRIDGE 1 // Running with an old worn out cartridge (max wear) // TODO sw config implemented // #define PBA_ESTIMATION 1 // Estimate arterial pressure rather than look at PBA sensor -// #define DISABLE_MOTOR_CURRENT_CHECKS 1 // Do not error on HD pump current checks // TODO sw config implemented -// #define DISABLE_PUMP_FLOW_CHECKS 1 // Do not error on HD pump flow checks // TODO sw config implemented -// #define DISABLE_PUMP_SPEED_CHECKS 1 // Do not error on HD pump speed checks // TODO sw config implemented -// #define DISABLE_PUMP_DIRECTION_CHECKS 1 // Do not error on HD pump direction checks // TODO sw config implemented -// #define DISABLE_SYRINGE_PUMP 1 // Disable syringe pump functionality // TODO sw config implemented -// #define ALWAYS_ALLOW_SYRINGE_PUMP_CMDS 1 // Allow syringe pump commands at any time except when pump is busy // TODO sw config implemented -// #define DISABLE_PRESSURE_CHECKS 1 // Do not error on HD pressure checks // TODO sw config implemented -// #define DISABLE_ARTERIAL_PRESSURE_CHECK 1 // Do not error on arterial pressure out of range // TODO sw config implemented -// #define DISABLE_VENOUS_PRESSURE_CHECK 1 // Do not error on venous pressure out of range // TODO sw config implemented #define USE_PBO_AS_PBA 1 // PBo readings used for PBA, PBo replaced with fixed pressure (100 mmHg) // #define DISABLE_UF_ALARMS 1 // Do not error on HD ultrafiltration checks @@ -77,24 +64,14 @@ // #define DISABLE_FPGA_COUNTER_CHECKS 1 // Disable alarms associated with FPGA read/error counters #define DISABLE_VOLTAGE_MONITOR 1 // Disable voltage monitoring/alarms #define ALLOW_1_MIN_TREATMENT_DURATION 1 // Allow user to change treatment duration to as low as 1 minute -// #define DISABLE_SYRINGE_PUMP_ALARMS 1 // Disable some syringe pump alarms that are triggering intermittently // TODO New config implemented // #define NO_PUMP_FLOW_LIMITS 1 // Allow any commanded flow rate for peristaltic pumps #define DISABLE_BUBBLE_ALARMS 1 // Disable bubble alarms #define DISABLE_UI_POST_TEST 1 // Disable the UI POST // #define DISABLE_UI_COMM_TO_ALARM 1 // Disable UI comm timeouts #define DISABLE_WD_AND_SFTY_POST_TESTS 1 // Disable watchdog and safety shutdown POST tests #define DISABLE_ILLEGAL_AIR_TRAP_ALARM 1 // Disable illegal state for air trap alarm #define SKIP_RESERVOIR_ALARMS 1 // Skip reservoir management alarms -// #define IGNORE_BLOOD_LEAK_SELF_TEST 1 // Ignore blood leak self test // TODO New config implemented -// #define IGNORE_BLOOD_LEAK_ALARM 1 // Ignore blood leak alarm // TODO New config implemented - // Skip Pre-Treatment and get to treatment as soon as possible -// #define SKIP_UI_INTERACTION 1 // Skip UI interaction. // TODO New config implemented -// #define SKIP_SAMPLE_WATER 1 // Skip pre-treatment sample water // TODO New config implemented -// #define SKIP_CONSUMABLE_TESTS 1 // Skip pre-treatment consumable Self-tests // TODO New config implemented -// #define SKIP_DRY_SELF_TESTS 1 // Skip pre-treatment dry self-tests // TODO New config implemented -// #define SKIP_PRIMING 1 // Skip Pre-treatment Prime // TODO New config implemented -// #define SKIP_WET_SELF_TESTS 1 // Skip Pre-treatment prime wet self-tests // TODO New config implemented #include #include