Index: firmware/App/HDCommon.h =================================================================== diff -u -rf3c8ef49b4bef41b606325e3db0e053a7a72d98f -r113f804decb50b9511bb8b7365288285fece6628 --- firmware/App/HDCommon.h (.../HDCommon.h) (revision f3c8ef49b4bef41b606325e3db0e053a7a72d98f) +++ firmware/App/HDCommon.h (.../HDCommon.h) (revision 113f804decb50b9511bb8b7365288285fece6628) @@ -10,8 +10,8 @@ * @author (last) Sean Nash * @date (last) 12-Nov-2021 * -* @author (original) Sean -* @date (original) 27-Feb-2020 +* @author (original) Sean +* @date (original) 27-Feb-2020 * ***************************************************************************/ @@ -24,8 +24,8 @@ #define HD_VERSION_MAJOR 0 #define HD_VERSION_MINOR 6 -#define HD_VERSION_MICRO 5 -#define HD_VERSION_BUILD 25 +#define HD_VERSION_MICRO 0 +#define HD_VERSION_BUILD 119 // ********** development build switches ********** @@ -49,18 +49,18 @@ // #define RUN_BP_OPEN_LOOP 1 // Run blood pump in open loop mode // #define RUN_DPI_OPEN_LOOP 1 // Run dialysate inlet pump in open loop mode #define WORN_OUT_CARTRIDGE 1 // Running with an old worn out cartridge (max wear) - #define PBA_ESTIMATION 1 // Estimate arterial pressure rather than look at PBA sensor +// #define PBA_ESTIMATION 1 // Estimate arterial pressure rather than look at PBA sensor #define DISABLE_MOTOR_CURRENT_CHECKS 1 // Do not error on HD pump current checks #define DISABLE_PUMP_FLOW_CHECKS 1 // Do not error on HD pump flow checks #define DISABLE_PUMP_SPEED_CHECKS 1 // Do not error on HD pump speed checks #define DISABLE_PUMP_DIRECTION_CHECKS 1 // Do not error on HD pump direction checks - #define DISABLE_SYRINGE_PUMP 1 // Disable syringe pump functionality +// #define DISABLE_SYRINGE_PUMP 1 // Disable syringe pump functionality #define ALWAYS_ALLOW_SYRINGE_PUMP_CMDS 1 // Allow syringe pump commands at any time except when pump is busy #define DISABLE_PRESSURE_CHECKS 1 // Do not error on HD pressure checks // #define DISABLE_UF_ALARMS 1 // Do not error on HD ultrafiltration checks #define DISABLE_DIALYSATE_TEMP_CHECK 1 // Disable dialysate temperature check -// #define DISABLE_VALVE_ALARMS 1 // Do not error on HD valve position - #define SKIP_CAL_CHECK 1 + #define DISABLE_VALVE_ALARMS 1 // Do not error on HD valve position + #define SKIP_CAL_CHECK 1 // // #define RUN_PUMPS_OPEN_LOOP 1 // BP and DPi pumps will be run open loop (no flow sensor feedback) // #define READ_FPGA_ASYNC_DATA 1 // Test build reads non-priority register page every other time // #define EMC_TEST_BUILD 1 // EMC test build - HD/DG run separately but connected, HD pumps toggle on/off w/ stop button @@ -73,7 +73,7 @@ // #define DISABLE_FPGA_COUNTER_CHECKS 1 // Disable alarms associated with FPGA read/error counters #define DISABLE_VOLTAGE_MONITOR 1 // Disable voltage monitoring/alarms #define ALLOW_1_MIN_TREATMENT_DURATION 1 // Allow user to change treatment duration to as low as 1 minute - #define DISABLE_SYRINGE_PUMP_ALARMS 1 // Disable some syringe pump alarms that are triggering intermittently +// #define DISABLE_SYRINGE_PUMP_ALARMS 1 // Disable some syringe pump alarms that are triggering intermittently // #define NO_PUMP_FLOW_LIMITS 1 // Allow any commanded flow rate for peristaltic pumps #define DISABLE_BUBBLE_ALARMS 1 // Disable bubble alarms #define DISABLE_UI_POST_TEST 1 // Disable the UI POST