Index: firmware/App/Modes/BloodPrime.c =================================================================== diff -u -rec348bf3bbbe48b5a5e25d563a0aa5686bfcd237 -re45524455c005d4fa1734efcbaf7ed0499302670 --- firmware/App/Modes/BloodPrime.c (.../BloodPrime.c) (revision ec348bf3bbbe48b5a5e25d563a0aa5686bfcd237) +++ firmware/App/Modes/BloodPrime.c (.../BloodPrime.c) (revision e45524455c005d4fa1734efcbaf7ed0499302670) @@ -36,17 +36,9 @@ // ********** private definitiions *********** -// TODO - get from Systems when available #define TARGET_BLOOD_PRIME_VOLUME_ML 300.0 ///< Target blood prime volume to prime the blood side circuit (in mL). #define MIN_RAMP_TIME_SEC 60 ///< Minimum ramp time for blood prime (in seconds). -#ifndef DISABLE_PUMP_FLOW_CHECKS -/// Maximum blood prime volume measured by independent means (as % of target). -static const F32 MAX_BLOOD_PRIME_SAFETY_VOLUME_ML = ( TARGET_BLOOD_PRIME_VOLUME_ML * 1.2 ); -/// Minimum blood prime volume measured by independent means (as % of target). -static const F32 MIN_BLOOD_PRIME_SAFETY_VOLUME_ML = ( TARGET_BLOOD_PRIME_VOLUME_ML * 0.8 ); -#endif - /// Initial flow rate for blood pump when starting blood prime operation. #define BLOOD_PRIME_INIT_BP_FLOW_RATE_ML_MIN 100 @@ -72,15 +64,11 @@ static OVERRIDE_U32_T bloodPrimePublishInterval = { BLOOD_PRIME_DATA_PUBLISH_INTERVAL, BLOOD_PRIME_DATA_PUBLISH_INTERVAL, BLOOD_PRIME_DATA_PUBLISH_INTERVAL, 0 }; static OVERRIDE_F32_T cumulativeBloodPrimeVolume_mL = { 0.0, 0.0, 0.0, 0 }; ///< Total cumulative blood prime volume (in mL). -static OVERRIDE_F32_T bloodPrimeVolumeDelivered_Safety = { 0.0, 0.0, 0.0, 0 }; ///< The cumulative independent blood prime volume (in mL) calculated so far. -static S32 bloodPrimeMotorCount; ///< The cumulative sum of BP motor encoder counts used for independent blood prime volume check. -static U32 bloodPrimeLastMotorCount; ///< The last BP motor encoder count read for independent blood prime volume check. // ********** private function prototypes ********** static void resetBloodPrimeFlags( void ); static F32 getBloodPrimeVolume( void ); -static F32 getBloodPrimeSafetyVolume( void ); static BLOOD_PRIME_STATE_T handleBloodPrimeRampState( void ); static void publishBloodPrimeData( void ); @@ -100,9 +88,6 @@ bloodPrimeRampControlTimerCtr = 0; bloodPrimePublishTimerCtr = BLOOD_PRIME_DATA_PUBLISH_INTERVAL; cumulativeBloodPrimeVolume_mL.data = 0.0; - bloodPrimeVolumeDelivered_Safety.data = 0.0; - bloodPrimeMotorCount = 0; - bloodPrimeLastMotorCount = getBloodPumpMotorCount(); resetBloodPrimeFlags(); bloodPrimeRampFlowRate_mL_min = (F32)BLOOD_PRIME_INIT_BP_FLOW_RATE_ML_MIN; @@ -194,26 +179,6 @@ /*********************************************************************//** * @brief - * The getBloodPrimeSafetyVolume function gets the calculated independent - * blood prime volume delivered. - * @details Inputs: bloodPrimeVolumeDelivered_Safety - * @details Outputs: none - * @return the current blood prime safety volume delivered (in mL). - *************************************************************************/ -static F32 getBloodPrimeSafetyVolume( void ) -{ - F32 result = bloodPrimeVolumeDelivered_Safety.data; - - if ( OVERRIDE_KEY == bloodPrimeVolumeDelivered_Safety.override ) - { - result = bloodPrimeVolumeDelivered_Safety.ovData; - } - - return result; -} - -/*********************************************************************//** - * @brief * The execBloodPrime function executes the Blood Prime sub-mode state machine. * @details Inputs: bloodPrimeState * @details Outputs: bloodPrimeState @@ -253,33 +218,20 @@ // Update blood prime volume delivered so far cumulativeBloodPrimeVolume_mL.data += ( getMeasuredBloodFlowRate() * BLOOD_PRIME_FLOW_INTEGRATOR ); - // Update independent calculated safety volume delivered so far - bloodPrimeMotorCount = u32BiDiffWithWrap( bloodPrimeLastMotorCount, getBloodPumpMotorCount() ) / BP_HALL_EDGE_COUNTS_PER_REV; - bloodPrimeVolumeDelivered_Safety.data = ( (F32)bloodPrimeMotorCount * VOLUME_PER_BP_MOTOR_REV_ML ); // TODO - include upstream pressure compensation to this calc // Has blood prime completed? if ( getBloodPrimeVolume() >= TARGET_BLOOD_PRIME_VOLUME_ML ) { -#ifndef DISABLE_PUMP_FLOW_CHECKS - // check for under-delivery - if ( getBloodPrimeSafetyVolume() < MIN_BLOOD_PRIME_SAFETY_VOLUME_ML ) - { - SET_ALARM_WITH_2_F32_DATA( ALARM_ID_BLOOD_PRIME_VOLUME_CHECK_FAILURE, TARGET_BLOOD_PRIME_VOLUME_ML, getBloodPrimeSafetyVolume() ); - } - else -#endif - { - setBloodIsPrimed( TRUE ); - signalDialInPumpHardStop(); - signalBloodPrimeToDialysis(); - cmdStopDGTrimmerHeater(); - } + setBloodIsPrimed( TRUE ); + signalDialInPumpHardStop(); + signalBloodPrimeToDialysis(); + cmdStopDGTrimmerHeater(); } #ifndef DISABLE_PUMP_FLOW_CHECKS - // Has independent safety volume exceeded safety limit? - else if ( getBloodPrimeSafetyVolume() > MAX_BLOOD_PRIME_SAFETY_VOLUME_ML ) + // Is blood prime taking too long based on set BP rate? + else if ( TBD ) { - SET_ALARM_WITH_2_F32_DATA( ALARM_ID_BLOOD_PRIME_VOLUME_CHECK_FAILURE, TARGET_BLOOD_PRIME_VOLUME_ML, getBloodPrimeSafetyVolume() ); + activateAlarmNoData( ALARM_ID_BLOOD_PRIME_VOLUME_CHECK_FAILURE ); } #endif else @@ -331,7 +283,7 @@ bloodPrimePublishTimerCtr = 0; data.targetBloodPrimeVolumeMl = TARGET_BLOOD_PRIME_VOLUME_ML; data.deliveredBloodPrimeVolumeMl = getBloodPrimeVolume(); - data.indDeliveredBloodPrimeVolumeMl = getBloodPrimeSafetyVolume(); + data.unused = 0.0; // TODO - remove later when UI no longer looking for this field. broadcastData( MSG_ID_HD_BLOOD_PRIME_PROGRESS, COMM_BUFFER_OUT_CAN_HD_BROADCAST, (U08*)&data, sizeof( BLOOD_PRIME_DATA_PAYLOAD_T ) ); } } @@ -389,51 +341,6 @@ /*********************************************************************//** * @brief - * The testSetBloodPrimeSafetyVolumeOverride function overrides the calculated - * blood prime volume. - * @details Inputs: none - * @details Outputs: bloodPrimeVolumeDelivered_Safety - * @param vol override calculated blood prime safety volume (in mL) - * @return TRUE if override successful, FALSE if not - *************************************************************************/ -BOOL testSetBloodPrimeSafetyVolumeOverride( F32 vol ) -{ - BOOL result = FALSE; - - if ( TRUE == isTestingActivated() ) - { - result = TRUE; - bloodPrimeVolumeDelivered_Safety.ovData = vol; - bloodPrimeVolumeDelivered_Safety.override = OVERRIDE_KEY; - } - - return result; -} - -/*********************************************************************//** - * @brief - * The testResetBloodPrimeSafetyVolumeOverride function resets the override of the - * calculated blood prime safety volume. - * @details Inputs: none - * @details Outputs: bloodPrimeVolumeDelivered_Safety - * @return TRUE if reset successful, FALSE if not - *************************************************************************/ -BOOL testResetBloodPrimeSafetyVolumeOverride( void ) -{ - BOOL result = FALSE; - - if ( TRUE == isTestingActivated() ) - { - result = TRUE; - bloodPrimeVolumeDelivered_Safety.override = OVERRIDE_RESET; - bloodPrimeVolumeDelivered_Safety.ovData = bloodPrimeVolumeDelivered_Safety.ovInitData; - } - - return result; -} - -/*********************************************************************//** - * @brief * The testSetBloodPrimePublishIntervalOverride function sets the override of the * blood prime data publication interval. * @details Inputs: none