Index: firmware/App/Modes/ModeTreatment.c =================================================================== diff -u -r5a6f0b9a41702cf284db0a356261da21f06c0bfc -rf70ddc5911bffe11fc5e670c8566164af4b6c88f --- firmware/App/Modes/ModeTreatment.c (.../ModeTreatment.c) (revision 5a6f0b9a41702cf284db0a356261da21f06c0bfc) +++ firmware/App/Modes/ModeTreatment.c (.../ModeTreatment.c) (revision f70ddc5911bffe11fc5e670c8566164af4b6c88f) @@ -8,7 +8,7 @@ * @file ModeTreatment.c * * @author (last) Sean Nash -* @date (last) 12-Jan-2024 +* @date (last) 22-Apr-2024 * * @author (original) Dara Navaei * @date (original) 05-Nov-2019 @@ -27,6 +27,8 @@ #include "ModeTreatmentParams.h" #include "NVDataMgmt.h" #include "OperationModes.h" +#include "PersistentAlarm.h" +#include "PresOccl.h" #include "Reservoirs.h" #include "Rinseback.h" #include "RTC.h" @@ -195,6 +197,11 @@ treatmentStartTimeStamp = getRTCTimestamp(); treatmentEndTimeStamp = 0; + + // reset dialysate temperature alarm persistences prior to starting a treatment. + resetPersistentAlarmTimer( ALARM_ID_HD_DIALYSATE_TEMP_ABOVE_SAFETY_TEMP ); + resetPersistentAlarmTimer( ALARM_ID_HD_DIALYSATE_TEMP_ABOVE_TARGET_TEMP ); + resetPersistentAlarmTimer( ALARM_ID_HD_DIALYSATE_TEMP_BELOW_TARGET_TEMP ); } /*********************************************************************//** @@ -746,6 +753,8 @@ sendTreatmentLogEventData( UF_START_RESUME_EVENT, 0.0, presUFRate ); } transitionToDialysis(); + // To update partial blood pump occlusion baseline - start of treatment + signalBloodPumpPressureOcclBaseline(); result = TREATMENT_DIALYSIS_STATE; } } @@ -1014,42 +1023,45 @@ *************************************************************************/ BOOL verifyTreatmentDurationSettingChange( U32 treatmentTime ) { - BOOL result = FALSE; + BOOL result = FALSE; REQUEST_REJECT_REASON_CODE_T rejectReason = REQUEST_REJECT_REASON_NONE; - HD_OP_MODE_T currMode = getCurrentOperationMode(); + HD_OP_MODE_T currMode = getCurrentOperationMode(); // Check if we are in an appropriate treatment state for settings adjustment if ( ( MODE_TREA == currMode ) && ( currentTreatmentState > TREATMENT_START_STATE ) && ( currentTreatmentState < TREATMENT_END_STATE ) && ( CALC_ELAPSED_TREAT_TIME_IN_MIN() < treatmentTime ) && ( treatmentTime >= getMinTreatmentTimeInMinutes() ) ) { - F32 uFVolume; - U32 dialVolume = getTreatmentParameterU32( TREATMENT_PARAM_DIALYSATE_FLOW ) * treatmentTime; // In mL - // Always adjust UF volume to accommodate treatment time change (not UF rate) - uFVolume = ( (F32)( treatmentTime - CALC_ELAPSED_TREAT_TIME_IN_MIN() ) * presUFRate ) + getUltrafiltrationReferenceVolume(); - if ( ( treatmentTime >= getU32TreatmentParamLowerRangeLimit( TREATMENT_PARAM_TREATMENT_DURATION ) ) && - ( treatmentTime <= getU32TreatmentParamUpperRangeLimit( TREATMENT_PARAM_TREATMENT_DURATION ) ) && - ( dialVolume <= MAX_DIALYSATE_VOLUME_ML ) && - ( uFVolume <= MAX_UF_VOLUME_ML ) ) + F32 uFVolume = ( (F32)( treatmentTime - CALC_ELAPSED_TREAT_TIME_IN_MIN() ) * presUFRate ) + getUltrafiltrationReferenceVolume(); + F32 uFVolumeL = uFVolume / ML_PER_LITER; + U32 dialVolume = getTreatmentParameterU32( TREATMENT_PARAM_DIALYSATE_FLOW ) * treatmentTime; // In mL + // The minimum treatment time is either in the range of the institutional record or the 1-minute treatment config has been requested which is an exception + BOOL isMinTxTimeValid = ( ( treatmentTime >= getU32TreatmentParamLowerRangeLimit( TREATMENT_PARAM_TREATMENT_DURATION ) ) || + ( TRUE == getTestConfigStatus( TEST_CONFIG_ENABLE_ONE_MINUTE_TREATMENT ) ) ? TRUE : FALSE ); + BOOL isTxTimeValid = ( ( TRUE == isMinTxTimeValid ) && + ( treatmentTime <= getU32TreatmentParamUpperRangeLimit( TREATMENT_PARAM_TREATMENT_DURATION ) ) ? TRUE : FALSE ); + BOOL isMinUFVolValid = ( ( uFVolumeL >= getF32TreatmentParamLowerRangeLimit( TREATMENT_PARAM_UF_VOLUME ) ) || ( uFVolumeL <= 0.0F ) ? TRUE : FALSE ); + BOOL isUFVolValid = ( ( TRUE == isMinUFVolValid ) && ( uFVolumeL <= getF32TreatmentParamUpperRangeLimit( TREATMENT_PARAM_UF_VOLUME ) ) ? TRUE : FALSE ); + + if ( ( TRUE == isTxTimeValid ) && ( dialVolume <= MAX_DIALYSATE_VOLUME_ML ) && ( TRUE == isUFVolValid ) ) { result = TRUE; sendTreatmentLogEventData( TREATMENT_DURATION_CHANGE_EVENT, ( presTreatmentTimeSecs / SEC_PER_MIN ), treatmentTime ); presMaxUFVolumeML = uFVolume; presTreatmentTimeSecs = treatmentTime * SEC_PER_MIN; - result &= setTreatmentParameterF32( TREATMENT_PARAM_UF_VOLUME, ( presMaxUFVolumeML / (F32)ML_PER_LITER ) ); - result &= setTreatmentParameterU32( TREATMENT_PARAM_TREATMENT_DURATION, ( presTreatmentTimeSecs / SEC_PER_MIN ) ); + setTreatmentParameterF32( TREATMENT_PARAM_UF_VOLUME, ( presMaxUFVolumeML / (F32)ML_PER_LITER ) ); + setTreatmentParameterU32( TREATMENT_PARAM_TREATMENT_DURATION, ( presTreatmentTimeSecs / SEC_PER_MIN ) ); setDialysisDialInFlowAndUFRate( getTreatmentParameterU32( TREATMENT_PARAM_DIALYSATE_FLOW ), presMaxUFVolumeML, presUFRate ); signalInitiatePressureStabilization( USE_NORMAL_STABILIZATION_PERIOD ); } else { - if ( ( treatmentTime < getU32TreatmentParamLowerRangeLimit( TREATMENT_PARAM_TREATMENT_DURATION ) ) || - ( treatmentTime > getU32TreatmentParamUpperRangeLimit( TREATMENT_PARAM_TREATMENT_DURATION ) ) ) + if ( FALSE == isTxTimeValid ) { rejectReason = REQUEST_REJECT_REASON_TREATMENT_TIME_OUT_OF_RANGE; } - else if ( uFVolume > MAX_UF_VOLUME_ML ) + else if ( FALSE == isUFVolValid ) { rejectReason = REQUEST_REJECT_REASON_UF_VOLUME_OUT_OF_RANGE; } @@ -1175,6 +1187,7 @@ } // UF volume cannot be set lower than the UF volume that has already been collected else if ( ( uFVolume > ( getF32TreatmentParamUpperRangeLimit( TREATMENT_PARAM_UF_VOLUME ) * ML_PER_LITER ) ) || + ( uFVolume < ( getF32TreatmentParamLowerRangeLimit( TREATMENT_PARAM_UF_VOLUME ) * ML_PER_LITER ) ) || ( uFVolume <= colUFVol ) ) { rejectReason = REQUEST_REJECT_REASON_UF_VOLUME_OUT_OF_RANGE; @@ -1294,6 +1307,8 @@ // Set to new rate result &= setTreatmentParameterU32( TREATMENT_PARAM_BLOOD_FLOW, bloodRate ); setDialysisBloodPumpFlowRate( getTreatmentParameterU32( TREATMENT_PARAM_BLOOD_FLOW ) ); + // Update partial occlusion baseline when blood flow rate changes + signalBloodPumpPressureOcclBaseline(); } // Handle dialysate flow rate changes @@ -1304,6 +1319,8 @@ // Set to new rate result &= setTreatmentParameterU32( TREATMENT_PARAM_DIALYSATE_FLOW, dialRate ); setDialysisDialInFlowAndUFRate( getTreatmentParameterU32( TREATMENT_PARAM_DIALYSATE_FLOW ), presMaxUFVolumeML, presUFRate ); + // Update partial occlusion baseline when dialysate flow rate changes + signalBloodPumpPressureOcclBaseline(); } } else