Index: firmware/App/HDCommon.h =================================================================== diff -u -rec76cd7277fc01f63dc29328bb40da032b9ef83b -r5c2822d5c0c20c0bb3c668ee2dba6eaeafdce986 --- firmware/App/HDCommon.h (.../HDCommon.h) (revision ec76cd7277fc01f63dc29328bb40da032b9ef83b) +++ firmware/App/HDCommon.h (.../HDCommon.h) (revision 5c2822d5c0c20c0bb3c668ee2dba6eaeafdce986) @@ -23,9 +23,9 @@ // ********** version ********** #define HD_VERSION_MAJOR 0 -#define HD_VERSION_MINOR 5 +#define HD_VERSION_MINOR 6 #define HD_VERSION_MICRO 0 -#define HD_VERSION_BUILD 9037 +#define HD_VERSION_BUILD 34 // ********** development build switches ********** @@ -47,40 +47,40 @@ // #define DISABLE_ACCELS 1 // Disable accelerometer POST and monitoring // #define DISABLE_CRC_ERROR 1 // Do not error on bad CRC for CAN messages // #define DISABLE_ACK_ERRORS 1 // Do not error on failure of other node(s) to ACK a message -// #define DISABLE_MOTOR_CURRENT_CHECKS 1 // Do not error on HD pump current checks -// #define DISABLE_PUMP_FLOW_CHECKS 1 // Do not error on HD pump flow checks -// #define DISABLE_PUMP_SPEED_CHECKS 1 // Do not error on HD pump speed checks -// #define DISABLE_PUMP_DIRECTION_CHECKS 1 // Do not error on HD pump direction checks -// #define DISABLE_SYRINGE_PUMP 1 // Disable syringe pump functionality + #define DISABLE_MOTOR_CURRENT_CHECKS 1 // Do not error on HD pump current checks + #define DISABLE_PUMP_FLOW_CHECKS 1 // Do not error on HD pump flow checks + #define DISABLE_PUMP_SPEED_CHECKS 1 // Do not error on HD pump speed checks + #define DISABLE_PUMP_DIRECTION_CHECKS 1 // Do not error on HD pump direction checks + #define DISABLE_SYRINGE_PUMP 1 // Disable syringe pump functionality #define ALWAYS_ALLOW_SYRINGE_PUMP_CMDS 1 // Allow syringe pump commands at any time except when pump is busy // #define DISABLE_PRESSURE_CHECKS 1 // Do not error on HD pressure checks -// #define DISABLE_UF_ALARMS 1 // Do not error on HD ultrafiltration checks -// #define DISABLE_VALVE_ALARMS 1 // Do not error on HD valve position + #define DISABLE_UF_ALARMS 1 // Do not error on HD ultrafiltration checks + #define DISABLE_VALVE_ALARMS 1 // Do not error on HD valve position #define DISABLE_CAL_CHECK 1 // Disable calibration checks // #define RUN_PUMPS_OPEN_LOOP 1 // BP and DPi pumps will be run open loop (no flow sensor feedback) // #define RAW_FLOW_SENSOR_DATA 1 // Test build will not filter flow sensor data // #define READ_FPGA_ASYNC_DATA 1 // Test build reads non-priority register page every other time // #define EMC_TEST_BUILD 1 // EMC test build - HD/DG run separately but connected, HD pumps toggle on/off w/ stop button #define ALARMS_DEBUG 1 // Triggered alarms sent to debug UART #define ALARM_VOLUME_DEFAULT_LOW 1 // Set default alarm volume to lowest - #define TEMP_UI_ALARM_SILENCE_FIX 1 // Temporary UI fix for handling alarm silence request msg +// #define TEMP_UI_ALARM_SILENCE_FIX 1 // Temporary UI fix for handling alarm silence request msg #define SKIP_PRIMING 1 // Skip Pre-treatment Prime #define SKIP_WET_SELF_TESTS 1 // Skip Pre-treatment prime wet self-tests // #define V2_0_SYSTEM 1 // Build for v2.0 system #define SKIP_SAMPLE_WATER 1 // Skip pre-treatment sample water #define SKIP_CONSUMABLE_TESTS 1 // Skip pre-treatment consumable Self-tests #define SKIP_DRY_SELF_TESTS 1 // Skip pre-treatment dry self-tests #define SKIP_UI_INTERACTION 1 // Skip UI interaction. -// #define DISABLE_BATT_COMM 1 // Disable battery communication. + #define DISABLE_BATT_COMM 1 // Disable battery communication. #define SKIP_AIR_BUBBLE_CHECK 1 // Skip air bubble detector self-test. #define DISABLE_OCCLUSION_SELF_TEST 1 // Skip occlusion sensor self-test. -// #define SKIP_CARTRIDGE_REMOVAL 1 // Skip cartridge removal check + #define SKIP_CARTRIDGE_REMOVAL 1 // Skip cartridge removal check #define SKIP_EMPTY_RES_CHECK 1 // Skip reservoir empty check -// #define DISABLE_FPGA_COUNTER_CHECKS 1 // Disable alarms associated with FPGA read/error counters -// #define DISABLE_VOLTAGE_MONITOR 1 // Disable voltage monitoring/alarms + #define DISABLE_FPGA_COUNTER_CHECKS 1 // Disable alarms associated with FPGA read/error counters + #define DISABLE_VOLTAGE_MONITOR 1 // Disable voltage monitoring/alarms #define ALLOW_1_MIN_TREATMENT_DURATION 1 // Allow user to change treatment duration to as low as 1 minute -// #define DISABLE_SYRINGE_PUMP_ALARMS 1 // Disable some syringe pump alarms that are triggering intermittently -// #define NO_PUMP_FLOW_LIMITS 1 // Allow any commanded flow rate for peristaltic pumps + #define DISABLE_SYRINGE_PUMP_ALARMS 1 // Disable some syringe pump alarms that are triggering intermittently + #define NO_PUMP_FLOW_LIMITS 1 // Allow any commanded flow rate for peristaltic pumps #define DISABLE_BUBBLE_ALARMS 1 // Disable bubble alarms #include