Index: firmware/App/HDCommon.h =================================================================== diff -u -r21180e0b65fddfa27f66d8fb59cb55b2db304230 -r6c34ce9c95ba654ebb9f880bf35b7e8c594184f1 --- firmware/App/HDCommon.h (.../HDCommon.h) (revision 21180e0b65fddfa27f66d8fb59cb55b2db304230) +++ firmware/App/HDCommon.h (.../HDCommon.h) (revision 6c34ce9c95ba654ebb9f880bf35b7e8c594184f1) @@ -25,7 +25,7 @@ #define HD_VERSION_MAJOR 0 #define HD_VERSION_MINOR 5 #define HD_VERSION_MICRO 0 -#define HD_VERSION_BUILD 9033 +#define HD_VERSION_BUILD 9035 // ********** development build switches ********** @@ -43,7 +43,7 @@ #define DISABLE_AIR_TRAP_LEVELING 1 // Disable air trap level control // #define DISABLE_3WAY_VALVES 1 // Disable 3-way valves // #define TST_3WAY_VALVES_ALWAYS_OPEN 1 // After POST and homing, open all 4 valves - #define DISABLE_ACCELS 1 // Disable accelerometer POST and monitoring +// #define DISABLE_ACCELS 1 // Disable accelerometer POST and monitoring // #define DISABLE_CRC_ERROR 1 // Do not error on bad CRC for CAN messages // #define DISABLE_ACK_ERRORS 1 // Do not error on failure of other node(s) to ACK a message #define DISABLE_MOTOR_CURRENT_CHECKS 1 // Do not error on HD pump current checks @@ -54,30 +54,33 @@ #define ALWAYS_ALLOW_SYRINGE_PUMP_CMDS 1 // Allow syringe pump commands at any time except when pump is busy #define DISABLE_PRESSURE_CHECKS 1 // Do not error on HD pressure checks // #define DISABLE_UF_ALARMS 1 // Do not error on HD ultrafiltration checks -// #define DISABLE_VALVE_ALARMS 1 // Do not error on HD valve position + #define DISABLE_VALVE_ALARMS 1 // Do not error on HD valve position #define DISABLE_CAL_CHECK 1 // Disable calibration checks // #define RUN_PUMPS_OPEN_LOOP 1 // BP and DPi pumps will be run open loop (no flow sensor feedback) // #define RAW_FLOW_SENSOR_DATA 1 // Test build will not filter flow sensor data // #define READ_FPGA_ASYNC_DATA 1 // Test build reads non-priority register page every other time // #define EMC_TEST_BUILD 1 // EMC test build - HD/DG run separately but connected, HD pumps toggle on/off w/ stop button #define ALARMS_DEBUG 1 // Triggered alarms sent to debug UART #define ALARM_VOLUME_DEFAULT_LOW 1 // Set default alarm volume to lowest - #define TEMP_UI_ALARM_SILENCE_FIX 1 // Temporary UI fix for handling alarm silence request msg +// #define TEMP_UI_ALARM_SILENCE_FIX 1 // Temporary UI fix for handling alarm silence request msg #define SKIP_PRIMING 1 // Skip Pre-treatment Prime #define SKIP_WET_SELF_TESTS 1 // Skip Pre-treatment prime wet self-tests // #define V1_5_SYSTEM 1 // Build for v1.5 system // #define V2_0_SYSTEM 1 // Build for v2.0 system - #define SKIP_SAMPLE_WATER 1 // Skip pre-treatment sample water +// #define SKIP_SAMPLE_WATER 1 // Skip pre-treatment sample water #define SKIP_CONSUMABLE_TESTS 1 // Skip pre-treatment consumable Self-tests #define SKIP_DRY_SELF_TESTS 1 // Skip pre-treatment dry self-tests - #define SKIP_UI_INTERACTION 1 // Skip UI interaction. +// #define SKIP_UI_INTERACTION 1 // Skip UI interaction. // #define DISABLE_BATT_COMM 1 // Disable battery communication. #define SKIP_AIR_BUBBLE_CHECK 1 // Skip air bubble detector self-test. #define DISABLE_OCCLUSION_SELF_TEST 1 // Skip occlusion sensor self-test. +// #define SKIP_CARTRIDGE_REMOVAL 1 // Skip cartridge removal check + #define SKIP_EMPTY_RES_CHECK 1 // Skip reservoir empty check #define DISABLE_FPGA_COUNTER_CHECKS 1 // Disable alarms associated with FPGA read/error counters #define DISABLE_VOLTAGE_MONITOR 1 // Disable voltage monitoring/alarms #define ALLOW_1_MIN_TREATMENT_DURATION 1 // Allow user to change treatment duration to as low as 1 minute + #include #include #endif