Index: firmware/App/HDCommon.h =================================================================== diff -u -red89b19b0b1fbab494fee7a762efae059f32b274 -r8a1cd1c30c5dacc8a3423145c93f83dd519f5824 --- firmware/App/HDCommon.h (.../HDCommon.h) (revision ed89b19b0b1fbab494fee7a762efae059f32b274) +++ firmware/App/HDCommon.h (.../HDCommon.h) (revision 8a1cd1c30c5dacc8a3423145c93f83dd519f5824) @@ -5,13 +5,13 @@ * THIS CODE MAY NOT BE COPIED OR REPRODUCED IN ANY FORM, IN PART OR IN * WHOLE, WITHOUT THE EXPLICIT PERMISSION OF THE COPYRIGHT OWNER. * -* @file HDCommon.h +* @file HDCommon.h * -* @author (last) Sean Nash -* @date (last) 14-Oct-2020 +* @author (last) Sean Nash +* @date (last) 14-Oct-2020 * -* @author (original) Sean -* @date (original) 27-Feb-2020 +* @author (original) Sean +* @date (original) 27-Feb-2020 * ***************************************************************************/ @@ -25,7 +25,7 @@ #define HD_VERSION_MAJOR 0 #define HD_VERSION_MINOR 6 #define HD_VERSION_MICRO 0 -#define HD_VERSION_BUILD 0 +#define HD_VERSION_BUILD 89 // ********** development build switches ********** @@ -56,8 +56,9 @@ // #define DISABLE_PUMP_DIRECTION_CHECKS 1 // Do not error on HD pump direction checks #define DISABLE_SYRINGE_PUMP 1 // Disable syringe pump functionality #define ALWAYS_ALLOW_SYRINGE_PUMP_CMDS 1 // Allow syringe pump commands at any time except when pump is busy + #define DISABLE_UF_ALARMS 1 // Do not error on HD ultrafiltration checks + #define DISABLE_DIALYSATE_TEMP_CHECK 1 // Disable dialysate temperature check // #define DISABLE_PRESSURE_CHECKS 1 // Do not error on HD pressure checks -// #define DISABLE_UF_ALARMS 1 // Do not error on HD ultrafiltration checks #define DISABLE_VALVE_ALARMS 1 // Do not error on HD valve position #define SKIP_CAL_CHECK 1 // // #define RUN_PUMPS_OPEN_LOOP 1 // BP and DPi pumps will be run open loop (no flow sensor feedback) @@ -71,7 +72,7 @@ #define DISABLE_OCCLUSION_SELF_TEST 1 // Skip occlusion sensor self-test. // #define SKIP_CARTRIDGE_REMOVAL 1 // Skip cartridge removal check // #define DISABLE_FPGA_COUNTER_CHECKS 1 // Disable alarms associated with FPGA read/error counters -// #define DISABLE_VOLTAGE_MONITOR 1 // Disable voltage monitoring/alarms + #define DISABLE_VOLTAGE_MONITOR 1 // Disable voltage monitoring/alarms #define ALLOW_1_MIN_TREATMENT_DURATION 1 // Allow user to change treatment duration to as low as 1 minute #define DISABLE_SYRINGE_PUMP_ALARMS 1 // Disable some syringe pump alarms that are triggering intermittently // #define NO_PUMP_FLOW_LIMITS 1 // Allow any commanded flow rate for peristaltic pumps