Index: firmware/App/Controllers/AirTrap.c =================================================================== diff -u -re5d1d67106a93a6cd1b5692b586625d715732e2f -r9b3f49e024c38a2a7aad8dbe383b3b6ab0e733f2 --- firmware/App/Controllers/AirTrap.c (.../AirTrap.c) (revision e5d1d67106a93a6cd1b5692b586625d715732e2f) +++ firmware/App/Controllers/AirTrap.c (.../AirTrap.c) (revision 9b3f49e024c38a2a7aad8dbe383b3b6ab0e733f2) @@ -82,8 +82,18 @@ *************************************************************************/ void initAirTrap( void ) { + U32 i; + resetAirTrap(); airTrapIllegalLevelSensorsCtr = 0; + + for ( i = 0; i < NUM_OF_AIR_TRAP_LEVEL_SENSORS; i++ ) + { + airTrapLevels[i].data = 0; + airTrapLevels[i].ovData = 0; + airTrapLevels[i].ovInitData = 0; + airTrapLevels[i].override = OVERRIDE_RESET; + } } /*********************************************************************//** Index: firmware/App/HDCommon.h =================================================================== diff -u -r4a86e82fceb9056cb5b2c7dec1b465698104ca61 -r9b3f49e024c38a2a7aad8dbe383b3b6ab0e733f2 --- firmware/App/HDCommon.h (.../HDCommon.h) (revision 4a86e82fceb9056cb5b2c7dec1b465698104ca61) +++ firmware/App/HDCommon.h (.../HDCommon.h) (revision 9b3f49e024c38a2a7aad8dbe383b3b6ab0e733f2) @@ -62,22 +62,24 @@ // #define EMC_TEST_BUILD 1 // EMC test build - HD/DG run separately but connected, HD pumps toggle on/off w/ stop button #define ALARMS_DEBUG 1 // Triggered alarms sent to debug UART #define ALARM_VOLUME_DEFAULT_LOW 1 // Set default alarm volume to lowest - #define TEMP_UI_ALARM_SILENCE_FIX 1 // Temporary UI fix for handling alarm silence request msg - #define SKIP_PRIMING 1 // Skip Pre-treatment Prime +// #define TEMP_UI_ALARM_SILENCE_FIX 1 // Temporary UI fix for handling alarm silence request msg +// #define SKIP_PRIMING 1 // Skip Pre-treatment Prime #define SKIP_WET_SELF_TESTS 1 // Skip Pre-treatment prime wet self-tests // #define V1_5_SYSTEM 1 // Build for v1.5 system // #define V2_0_SYSTEM 1 // Build for v2.0 system - #define SKIP_SAMPLE_WATER 1 // Skip pre-treatment sample water +// #define SKIP_SAMPLE_WATER 1 // Skip pre-treatment sample water #define SKIP_CONSUMABLE_TESTS 1 // Skip pre-treatment consumable Self-tests #define SKIP_DRY_SELF_TESTS 1 // Skip pre-treatment dry self-tests - #define SKIP_UI_INTERACTION 1 // Skip UI interaction. +// #define SKIP_UI_INTERACTION 1 // Skip UI interaction. // #define DISABLE_BATT_COMM 1 // Disable battery communication. #define SKIP_AIR_BUBBLE_CHECK 1 // Skip air bubble detector self-test. #define DISABLE_OCCLUSION_SELF_TEST 1 // Skip occlusion sensor self-test. +// #define SKIP_CARTRIDGE_REMOVAL 1 // Skip cartridge removal check + #define SKIP_EMPTY_RES_CHECK 1 // Skip reservoir empty check #define DISABLE_FPGA_COUNTER_CHECKS 1 // Disable alarms associated with FPGA read/error counters #define DISABLE_VOLTAGE_MONITOR 1 // Disable voltage monitoring/alarms #define ALLOW_1_MIN_TREATMENT_DURATION 1 // Allow user to change treatment duration to as low as 1 minute -// #define SLOW_SYRINGE_RETRACT 1 // Slow retract speed to reduce chance of stall + #define SLOW_SYRINGE_RETRACT 1 // Slow retract speed to reduce chance of stall #define DISABLE_SYRINGE_PUMP_ALARMS 1 // Disable some syringe pump alarms that are triggering intermittently #include