Index: firmware/App/Controllers/DialOutFlow.c =================================================================== diff -u -r8466e63f95f65a3ffb18c3af85ac99328e41167b -rcce9dc093c569089e29b52faffceb2701469a7cd --- firmware/App/Controllers/DialOutFlow.c (.../DialOutFlow.c) (revision 8466e63f95f65a3ffb18c3af85ac99328e41167b) +++ firmware/App/Controllers/DialOutFlow.c (.../DialOutFlow.c) (revision cce9dc093c569089e29b52faffceb2701469a7cd) @@ -853,7 +853,7 @@ F32 measMCMotorSpeed = fabs( getMeasuredDialOutPumpMCSpeed() ); // Check for pump running while commanded off - if ( dialOutPumpPWMDutyCyclePctSet > DOP_PWM_ZERO_OFFSET ) + if ( dialOutPumpPWMDutyCyclePctSet <= DOP_PWM_ZERO_OFFSET ) { if ( measMotorSpeed > DOP_MAX_MOTOR_SPEED_WHILE_OFF_RPM ) {