Index: etc/reports/alarms/AlarmMapping.csv =================================================================== diff -u -r712f4c8a1b2382919300895b4422b831471044a3 -r6be4c52f8c02087da143542a7b4539294803f060 --- etc/reports/alarms/AlarmMapping.csv (.../AlarmMapping.csv) (revision 712f4c8a1b2382919300895b4422b831471044a3) +++ etc/reports/alarms/AlarmMapping.csv (.../AlarmMapping.csv) (revision 6be4c52f8c02087da143542a7b4539294803f060) @@ -1,7 +1,7 @@ 0,"Indication for when no alarms is a possible situation." 1,"TD Software fault.\nSoftware found itself in an unexpected state." 2,"DD software fault.\nSoftware found itself in an unexpected state." - 3,"RO software fault.\nSoftware found itself in an unexpected state." + 3,"FP software fault.\nSoftware found itself in an unexpected state." 4,"TD FPGA POST failure." 5,"TD Watchdog POST failure." 6,"TD UI communication POST failure.\nUI failed to communicate within a reasonable time after power up." @@ -17,7 +17,7 @@ 16,"TD watchdog expired." 17,"DD watchdog expired." 18,"DD too many bad communications CRC." - 19,"DD didn't get ACK on message to RO that required acknowledgment." + 19,"DD didn't get ACK on message to FP that required acknowledgment." 20,"DD didn't get ACK on message to TD that required acknowledgment." 21,"DD FPGA POST failure." 22,"DD processor clock speed checks against FPGA clock failure." @@ -26,11 +26,11 @@ 25,"DD FPGA not accepting commanded valve states." 26,"TD arterial pressure sensor freshness/error timeout fault." 27,"TD venous pressure sensor freshness/error timeout fault." - 28,"DD hydraulics outlet pressure sensor freshness/error timeout fault." - 29,"DD bibag pressure sensor freshness/error timeout fault." - 30,"DD spent dialysate pressure sensor freshness/error timeout fault." - 31,"DD fresh dialysate pressure sensor freshness/error timeout fault." - 32,"DD transmembrane pressure sensor freshness/error timeout fault." + 28,"TD TMP pressure low." + 29,"TD TMP pressure high." + 30,"TD venous bubble self-test failure." + 31,"TD blood prime pause warning." + 32,"TD blood prime pause timeout." 33,"TD voltage out of range fault." 34,"TD AC power lost." 35,"TD AC power lost during treatment." @@ -56,7 +56,7 @@ 55,"DD concentrate pump fault." 56,"DD temperature sensor out of range." 57,"DD temperature sensors freshness timeout fault." - 58,"DD baro sensors freshness timeout fault." + 58,"DD balancing chamber fill timeout fault." 59,"DD barometric sensor coefficients bad CRC." 60,"DD fresh dialysate pump RPM out of range." 61,"DD fresh dialysate pump running when it is not commanded to run." @@ -70,34 +70,34 @@ 69,"DD spent dialysate pump direction error count FPGA fault." 70,"DD primary heater is On when no fluid is present." 71,"DD trimmer heater is On when no fluid is present." - 72,"DD water inlet input pressure sensor freshness/error timeout fault." - 73,"DD water inlet output pressure sensor freshness/error timeout fault." - 74,"DD inlet water pressure input low range." - 75,"DD inlet water pressure input high range." - 76,"DD inlet water pressure output low range." - 77,"DD inlet water pressure output high range." - 78,"TD air trap fill timeout alarm during treatment." + 72,"TD barometric sensor coefficients bad CRC." + 73,"TD barometric sensor pressure out of range." + 74,"DD UF pump speed control error." + 75,"DD spent chamber state 1 fill pressure out of range." + 76,"DD spent chamber state 2 fill pressure out of range." + 77,"DD spent chamber fill timeout fault." + 78,"TD air trap fill timeout." 79,"TD air trap illegal levels." 80,"TD pinch valve fault." 81,"TD pinch valve homing fault." 82,"TD pinch valve transition timeout." - 83,"RO can message not acked by DD fault." - 84,"RO FPGA communication timeout." - 85,"RO too many bad crcs." - 86,"RO valve control failure." + 83,"FP can message not acked by DD fault." + 84,"FP FPGA communication timeout." + 85,"FP too many bad crcs." + 86,"FP valve control failure." 87,"DD balance chamber state1 fill start pressure not in range." 88,"DD balance chamber state1 fill end pressure not in range." 89,"DD balance chamber state2 fill start pressure not in range." 90,"DD balance chamber state2 fill end pressure not in range." 91,"DD generate dialysate hydraulics chamber ngative pressure out of range." - 92,"Available alarms." - 93,"Available alarms." + 92,"DD spent chamber fill timeout fault." + 93,"DD D79 rinse pump commanded vs measured speed out of tolerance." 94,"DD balance chamber state1 fill initiated and pressure drop is not in range." 95,"DD balance chamber state2 fill initiated and pressure drop is not in range." 96,"TD treatment paused by user." 97,"DD D74 bicarb conductivity sensor freshness/error timeout fault." - 98,"Available alarms." - 99,"Available alarms." + 98,"TD blood sitting too long warning." + 99,"TD blood sitting too long alarm; no resume; no rinseback." 100,"TD communication timeout." 101,"UI POST OS version compatibility failure." 102,"UI POST Application Integrity (Sha256Sum) failure." @@ -130,4 +130,59 @@ 129,"UI Reserved failure." 130,"UI Reserved failure." 131,"TD Battery Low warning." - 132,"Number of alarms." + 132,"DD dialysate temperature above safety." + 133,"DD dialysate temperature high." + 134,"DD dialysate temperature low." + 135,"FP Pressure relief valve low." + 136,"FP Pressure relief valve high." + 137,"FP Power budget exceeded." + 138,"FP flow rate low." + 139,"FP inlet water temperature low." + 140,"FP inlet water temperature high." + 141,"FP inlet pressure low." + 142,"FP inlet pressure high." + 143,"FP inlet conductivity high." + 144,"FP inlet conductivty low." + 145,"FP pump inlet pressure high." + 146,"FP pump outlet conductivity high." + 147,"FP pump inlet conductivity high." + 148,"FP rejection ratio low." + 149,"FP inlet pressure regulator out of range." + 150,"FP inlet temperature above 40C during filters flush." + 151,"FP membrane flush timeout." + 152,"FP concentrate flush tank full timeout." + 153,"FP tank full time out alarm." + 154,"DD dialysate temperature sensors out of range." + 155,"DD blood leak detected." + 156,"DD blood leak invalid calibration record." + 157,"DD blood leak sensor embedded mode failure." + 158,"DD blood leak sensor set point failure." + 159,"DD blood leak sensor recovering please wait." + 160,"FP tank fill time out alarm." + 161,"FP inlet pressure high fault." + 162,"FP permeate flow high fault." + 163,"FP permeate flow low fault." + 164,"FP inlet pressure low fault." + 165,"TD air trap lower timeout." + 166,"TD syringe pump self-test failure alarm." + 167,"TD syringe pump is running while the BP is off." + 168,"TD syringe pump ADC FPGA fault." + 169,"TD syringe pump fault reported by FPGA." + 170,"TD syringe pump DAC write failure." + 171,"TD syringe pump speed check error." + 172,"TD syringe pump volume check error." + 173,"TD syringe pump over travel error." + 174,"TD syringe pump not stopped in off state error." + 175,"TD syringe pump direction (from encoder) error." + 176,"TD syringe pump direction (from controller) error." + 177,"TD syringe empty alarm." + 178,"TD syringe pump syringe removed alarm." + 179,"TD syringe pump stall alarm." + 180,"TD heparin force sensor invalid calibration record." + 181,"TD syringe detected alarm." + 182,"TD syringe pump not enough Heparin alarm." + 183,"TD syringe pump occlusion alarm." + 184,"TD syringe pump prime timeout." + 185,"FP P9 conductivity sensor fpga fault." + 186,"FP P18 conductivity sensor fpga fault." + 187,"Number of alarms."