Index: etc/reports/alarms/AlarmMapping.csv =================================================================== diff -u -r712f4c8a1b2382919300895b4422b831471044a3 -rc43d24c50f4344348d36d8ae9273797f4557356a --- etc/reports/alarms/AlarmMapping.csv (.../AlarmMapping.csv) (revision 712f4c8a1b2382919300895b4422b831471044a3) +++ etc/reports/alarms/AlarmMapping.csv (.../AlarmMapping.csv) (revision c43d24c50f4344348d36d8ae9273797f4557356a) @@ -1,7 +1,7 @@ 0,"Indication for when no alarms is a possible situation." 1,"TD Software fault.\nSoftware found itself in an unexpected state." 2,"DD software fault.\nSoftware found itself in an unexpected state." - 3,"RO software fault.\nSoftware found itself in an unexpected state." + 3,"FP software fault.\nSoftware found itself in an unexpected state." 4,"TD FPGA POST failure." 5,"TD Watchdog POST failure." 6,"TD UI communication POST failure.\nUI failed to communicate within a reasonable time after power up." @@ -17,7 +17,7 @@ 16,"TD watchdog expired." 17,"DD watchdog expired." 18,"DD too many bad communications CRC." - 19,"DD didn't get ACK on message to RO that required acknowledgment." + 19,"DD didn't get ACK on message to FP that required acknowledgment." 20,"DD didn't get ACK on message to TD that required acknowledgment." 21,"DD FPGA POST failure." 22,"DD processor clock speed checks against FPGA clock failure." @@ -72,32 +72,32 @@ 71,"DD trimmer heater is On when no fluid is present." 72,"DD water inlet input pressure sensor freshness/error timeout fault." 73,"DD water inlet output pressure sensor freshness/error timeout fault." - 74,"DD inlet water pressure input low range." - 75,"DD inlet water pressure input high range." - 76,"DD inlet water pressure output low range." - 77,"DD inlet water pressure output high range." + 74,"DD UF pump speed control error." + 75,"DD spent chamber state 1 fill pressure out of range." + 76,"DD spent chamber state 2 fill pressure out of range." + 77,"DD spent chamber fill timeout fault." 78,"TD air trap fill timeout alarm during treatment." 79,"TD air trap illegal levels." 80,"TD pinch valve fault." 81,"TD pinch valve homing fault." 82,"TD pinch valve transition timeout." - 83,"RO can message not acked by DD fault." - 84,"RO FPGA communication timeout." - 85,"RO too many bad crcs." - 86,"RO valve control failure." + 83,"FP can message not acked by DD fault." + 84,"FP FPGA communication timeout." + 85,"FP too many bad crcs." + 86,"FP valve control failure." 87,"DD balance chamber state1 fill start pressure not in range." 88,"DD balance chamber state1 fill end pressure not in range." 89,"DD balance chamber state2 fill start pressure not in range." 90,"DD balance chamber state2 fill end pressure not in range." 91,"DD generate dialysate hydraulics chamber ngative pressure out of range." - 92,"Available alarms." + 92,"DD spent chamber fill timeout fault." 93,"Available alarms." 94,"DD balance chamber state1 fill initiated and pressure drop is not in range." 95,"DD balance chamber state2 fill initiated and pressure drop is not in range." 96,"TD treatment paused by user." 97,"DD D74 bicarb conductivity sensor freshness/error timeout fault." - 98,"Available alarms." - 99,"Available alarms." + 98,"TD blood sitting too long warning." + 99,"TD blood sitting too long alarm; no resume; no rinseback." 100,"TD communication timeout." 101,"UI POST OS version compatibility failure." 102,"UI POST Application Integrity (Sha256Sum) failure." @@ -130,4 +130,33 @@ 129,"UI Reserved failure." 130,"UI Reserved failure." 131,"TD Battery Low warning." - 132,"Number of alarms." + 132,"DD dialysate temperature above safety." + 133,"DD dialysate temperature high." + 134,"DD dialysate temperature low." + 135,"FP Pressure relief valve low." + 136,"FP Pressure relief valve high." + 137,"FP Power budget exceeded." + 138,"FP flow rate low." + 139,"FP inlet water temperature low." + 140,"FP inlet water temperature high." + 141,"FP inlet pressure low." + 142,"FP inlet pressure high." + 143,"FP inlet conductivity high." + 144,"FP inlet conductivty low." + 145,"FP pump inlet pressure high." + 146,"FP pump outlet conductivity high." + 147,"FP pump inlet conductivity high." + 148,"FP rejection ratio low." + 149,"FP inlet pressure regulator out of range." + 150,"FP filter health pressure out of range." + 151,"FP membrane flush timeout." + 152,"FP membrane flush integrated out of range." + 153,"FP tank full time out alarm." + 154,"DD dialysate temperature sensors out of range." + 155,"DD blood leak detected." + 156,"DD blood leak invalid calibration record." + 157,"DD blood leak sensor embedded mode failure." + 158,"DD blood leak sensor set point failure." + 159,"DD blood leak sensor recovering please wait." + 160,"FP tank fill time out alarm." + 161,"Number of alarms."