Index: sources/model/hd/alarm/MAlarmMapping.cpp =================================================================== diff -u -recdaa15d6f9cfcf8967d458d9ddabd1d5c42ad5f -r701916b565680f1d5a6e85f25a72d4cc17dbc402 --- sources/model/hd/alarm/MAlarmMapping.cpp (.../MAlarmMapping.cpp) (revision ecdaa15d6f9cfcf8967d458d9ddabd1d5c42ad5f) +++ sources/model/hd/alarm/MAlarmMapping.cpp (.../MAlarmMapping.cpp) (revision 701916b565680f1d5a6e85f25a72d4cc17dbc402) @@ -63,7 +63,7 @@ /*0027*/case GuiAlarmID::ALARM_ID_TD_VENOUS_SENSOR_TIMEOUT_FAULT : { result = QObject::tr("TD venous pressure sensor freshness/error timeout fault." ); break; } /* 27*/ /*0028*/case GuiAlarmID::ALARM_ID_TD_TMP_PRESSURE_LOW : { result = QObject::tr("TD TMP pressure low." ); break; } /* 28*/ /*0029*/case GuiAlarmID::ALARM_ID_TD_TMP_PRESSURE_HIGH : { result = QObject::tr("TD TMP pressure high." ); break; } /* 29*/ -/*0030*/case GuiAlarmID::ALARM_ID_AVAILABLE_30 : { result = QObject::tr("Available alarms." ); break; } /* 30*/ +/*0030*/case GuiAlarmID::ALARM_ID_TD_VENOUS_BUBBLE_SELF_TEST_FAILURE : { result = QObject::tr("TD venous bubble self-test failure." ); break; } /* 30*/ /*0031*/case GuiAlarmID::ALARM_ID_AVAILABLE_31 : { result = QObject::tr("Available alarms." ); break; } /* 31*/ /*0032*/case GuiAlarmID::ALARM_ID_AVAILABLE_32 : { result = QObject::tr("Available alarms." ); break; } /* 32*/ /*0033*/case GuiAlarmID::ALARM_ID_TD_VOLTAGE_OUT_OF_RANGE : { result = QObject::tr("TD voltage out of range fault." ); break; } /* 33*/ @@ -91,7 +91,7 @@ /*0055*/case GuiAlarmID::ALARM_ID_DD_CONCENTRATE_PUMP_FAULT : { result = QObject::tr("DD concentrate pump fault." ); break; } /* 55*/ /*0056*/case GuiAlarmID::ALARM_ID_DD_TEMPERATURE_SENSOR_OUT_OF_RANGE : { result = QObject::tr("DD temperature sensor out of range." ); break; } /* 56*/ /*0057*/case GuiAlarmID::ALARM_ID_DD_RTD_SENSORS_FPGA_FAULT : { result = QObject::tr("DD temperature sensors freshness timeout fault." ); break; } /* 57*/ -/*0058*/case GuiAlarmID::ALARM_ID_AVAILABLE_58 : { result = QObject::tr("DD Available alarms." ); break; } /* 58*/ +/*0058*/case GuiAlarmID::ALARM_ID_DD_BC_FILL_TIMEOUT_FAULT : { result = QObject::tr("DD balancing chamber fill timeout fault." ); break; } /* 58*/ /*0059*/case GuiAlarmID::ALARM_ID_DD_BAROMETRIC_SENSOR_COEFFS_BAD_CRC : { result = QObject::tr("DD barometric sensor coefficients bad CRC." ); break; } /* 59*/ /*0060*/case GuiAlarmID::ALARM_ID_DD_D12_PUMP_RPM_OUT_OF_RANGE : { result = QObject::tr("DD fresh dialysate pump RPM out of range." ); break; } /* 60*/ /*0061*/case GuiAlarmID::ALARM_ID_DD_D12_PUMP_OFF_FAULT : { result = QObject::tr("DD fresh dialysate pump running when it is not commanded to run." ); break; } /* 61*/