Index: sources/model/hd/alarm/MAlarmMapping.cpp =================================================================== diff -u -r1286d74bd015276aab604808be2766136091c125 -r96dac796e87a62e65229b52740e3b9a7800f6457 --- sources/model/hd/alarm/MAlarmMapping.cpp (.../MAlarmMapping.cpp) (revision 1286d74bd015276aab604808be2766136091c125) +++ sources/model/hd/alarm/MAlarmMapping.cpp (.../MAlarmMapping.cpp) (revision 96dac796e87a62e65229b52740e3b9a7800f6457) @@ -64,8 +64,8 @@ /*0028*/case GuiAlarmID::ALARM_ID_TD_TMP_PRESSURE_LOW : { result = QObject::tr("TD TMP pressure low." ); break; } /* 28*/ /*0029*/case GuiAlarmID::ALARM_ID_TD_TMP_PRESSURE_HIGH : { result = QObject::tr("TD TMP pressure high." ); break; } /* 29*/ /*0030*/case GuiAlarmID::ALARM_ID_TD_VENOUS_BUBBLE_SELF_TEST_FAILURE : { result = QObject::tr("TD venous bubble self-test failure." ); break; } /* 30*/ -/*0031*/case GuiAlarmID::ALARM_ID_AVAILABLE_31 : { result = QObject::tr("Available alarms." ); break; } /* 31*/ -/*0032*/case GuiAlarmID::ALARM_ID_AVAILABLE_32 : { result = QObject::tr("Available alarms." ); break; } /* 32*/ +/*0031*/case GuiAlarmID::ALARM_ID_TD_BLOOD_PRIME_PAUSE_WARNING : { result = QObject::tr("TD blood prime pause warning." ); break; } /* 31*/ +/*0032*/case GuiAlarmID::ALARM_ID_TD_BLOOD_PRIME_PAUSE_TIMEOUT : { result = QObject::tr("TD blood prime pause timeout." ); break; } /* 32*/ /*0033*/case GuiAlarmID::ALARM_ID_TD_VOLTAGE_OUT_OF_RANGE : { result = QObject::tr("TD voltage out of range fault." ); break; } /* 33*/ /*0034*/case GuiAlarmID::ALARM_ID_TD_AC_POWER_LOST : { result = QObject::tr("TD AC power lost." ); break; } /* 34*/ /*0035*/case GuiAlarmID::ALARM_ID_TD_AC_POWER_LOST_IN_TREATMENT : { result = QObject::tr("TD AC power lost during treatment." ); break; } /* 35*/ @@ -199,8 +199,28 @@ /*0163*/case GuiAlarmID::ALARM_ID_FP_PERMEATE_FLOW_OUT_LOW_RANGE : { result = QObject::tr("FP permeate flow low fault." ); break; } /* 163*/ /*0164*/case GuiAlarmID::ALARM_ID_FP_INLET_PRESSURE_LOW_RANGE : { result = QObject::tr("FP inlet pressure low fault." ); break; } /* 164*/ /*0165*/case GuiAlarmID::ALARM_ID_TD_AIR_TRAP_LOWER_TIMEOUT : { result = QObject::tr("TD air trap lower timeout." ); break; } /* 165*/ -/*0166*/case GuiAlarmID::ALARM_ID_TD_AIR_PUMP_STALL : { result = QObject::tr("TD air pump stall detected." ); break; } /* 166*/ -/*0167*/case GuiAlarmID::NUM_OF_ALARM_IDS : { result = QObject::tr("Number of alarms." ); break; } /* 167*/ +/*0166*/case GuiAlarmID::ALARM_ID_TD_SYRINGE_PUMP_SELF_TEST_FAILURE : { result = QObject::tr("TD syringe pump self-test failure alarm." ); break; } /* 166*/ +/*0167*/case GuiAlarmID::ALARM_ID_TD_SYRINGE_PUMP_RUNNING_WHILE_BP_OFF_ERROR : { result = QObject::tr("TD syringe pump is running while the BP is off." ); break; } /* 167*/ +/*0168*/case GuiAlarmID::ALARM_ID_TD_SYRINGE_PUMP_FPGA_ADC_FAULT : { result = QObject::tr("TD syringe pump ADC FPGA fault." ); break; } /* 168*/ +/*0169*/case GuiAlarmID::ALARM_ID_TD_SYRINGE_PUMP_FAULT : { result = QObject::tr("TD syringe pump fault reported by FPGA." ); break; } /* 169*/ +/*0170*/case GuiAlarmID::ALARM_ID_TD_SYRINGE_PUMP_DAC_WRITE_ERROR : { result = QObject::tr("TD syringe pump DAC write failure." ); break; } /* 170*/ +/*0171*/case GuiAlarmID::ALARM_ID_TD_SYRINGE_PUMP_SPEED_ERROR : { result = QObject::tr("TD syringe pump speed check error." ); break; } /* 171*/ +/*0172*/case GuiAlarmID::ALARM_ID_TD_SYRINGE_PUMP_VOLUME_ERROR : { result = QObject::tr("TD syringe pump volume check error." ); break; } /* 172*/ +/*0173*/case GuiAlarmID::ALARM_ID_TD_SYRINGE_PUMP_OVER_TRAVEL_ERROR : { result = QObject::tr("TD syringe pump over travel error." ); break; } /* 173*/ +/*0174*/case GuiAlarmID::ALARM_ID_TD_SYRINGE_PUMP_NOT_STOPPED_ERROR : { result = QObject::tr("TD syringe pump not stopped in off state error." ); break; } /* 174*/ +/*0175*/case GuiAlarmID::ALARM_ID_TD_SYRINGE_PUMP_ENCODER_DIRECTION_ERROR : { result = QObject::tr("TD syringe pump direction (from encoder) error." ); break; } /* 175*/ +/*0176*/case GuiAlarmID::ALARM_ID_TD_SYRINGE_PUMP_CONTROLLER_DIRECTION_ERROR : { result = QObject::tr("TD syringe pump direction (from controller) error." ); break; } /* 176*/ +/*0177*/case GuiAlarmID::ALARM_ID_TD_SYRINGE_PUMP_SYRINGE_EMPTY : { result = QObject::tr("TD syringe empty alarm." ); break; } /* 177*/ +/*0178*/case GuiAlarmID::ALARM_ID_TD_SYRINGE_PUMP_SYRINGE_REMOVED : { result = QObject::tr("TD syringe pump syringe removed alarm." ); break; } /* 178*/ +/*0179*/case GuiAlarmID::ALARM_ID_TD_SYRINGE_PUMP_STALL : { result = QObject::tr("TD syringe pump stall alarm." ); break; } /* 179*/ +/*0180*/case GuiAlarmID::ALARM_ID_TD_HEPARIN_FORCE_SENSOR_INVALID_CAL_RECORD : { result = QObject::tr("TD heparin force sensor invalid calibration record." ); break; } /* 180*/ +/*0181*/case GuiAlarmID::ALARM_ID_TD_SYRINGE_DETECTED : { result = QObject::tr("TD syringe detected alarm." ); break; } /* 181*/ +/*0182*/case GuiAlarmID::ALARM_ID_TD_SYRINGE_PUMP_NOT_ENOUGH_HEPARIN_ALARM : { result = QObject::tr("TD syringe pump not enough Heparin alarm." ); break; } /* 182*/ +/*0183*/case GuiAlarmID::ALARM_ID_TD_SYRINGE_PUMP_OCCLUSION : { result = QObject::tr("TD syringe pump occlusion alarm." ); break; } /* 183*/ +/*0184*/case GuiAlarmID::ALARM_ID_TD_SYRINGE_PUMP_PRIME_TIMEOUT : { result = QObject::tr("TD syringe pump prime timeout." ); break; } /* 184*/ +/*0185*/case GuiAlarmID::ALARM_ID_FP_P9_COND_SENSOR_FPGA_FAULT : { result = QObject::tr("FP P9 conductivity sensor fpga fault." ); break; } /* 185*/ +/*0186*/case GuiAlarmID::ALARM_ID_FP_P18_COND_SENSOR_FPGA_FAULT : { result = QObject::tr("FP P18 conductivity sensor fpga fault." ); break; } /* 186*/ +/*0187*/case GuiAlarmID::NUM_OF_ALARM_IDS : { result = QObject::tr("Number of alarms." ); break; } /* 187*/ default: result = QObject::tr("ALARM_ID_UNDEFINED [%1]").arg(int(vAlarmID));