Index: sources/model/hd/alarm/MAlarmMapping.cpp =================================================================== diff -u -r0b388a9100a6492edeae094dca03b799b98dac6e -recdaa15d6f9cfcf8967d458d9ddabd1d5c42ad5f --- sources/model/hd/alarm/MAlarmMapping.cpp (.../MAlarmMapping.cpp) (revision 0b388a9100a6492edeae094dca03b799b98dac6e) +++ sources/model/hd/alarm/MAlarmMapping.cpp (.../MAlarmMapping.cpp) (revision ecdaa15d6f9cfcf8967d458d9ddabd1d5c42ad5f) @@ -111,7 +111,7 @@ /*0075*/case GuiAlarmID::ALARM_ID_DD_SC_STATE1_FILL_START_PRESSURE_OUT_OF_RANGE: { result = QObject::tr("DD spent chamber state 1 fill pressure out of range." ); break; } /* 75*/ /*0076*/case GuiAlarmID::ALARM_ID_DD_SC_STATE2_FILL_START_PRESSURE_OUT_OF_RANGE: { result = QObject::tr("DD spent chamber state 2 fill pressure out of range." ); break; } /* 76*/ /*0077*/case GuiAlarmID::ALARM_ID_DD_SC_FILL_TIMEOUT_FAULT : { result = QObject::tr("DD spent chamber fill timeout fault." ); break; } /* 77*/ -/*0078*/case GuiAlarmID::ALARM_ID_TD_AIR_TRAP_FILL_DURING_TREATMENT : { result = QObject::tr("TD air trap fill timeout alarm during treatment." ); break; } /* 78*/ +/*0078*/case GuiAlarmID::ALARM_ID_TD_AIR_TRAP_FILL_TIMEOUT : { result = QObject::tr("TD air trap fill timeout." ); break; } /* 78*/ /*0079*/case GuiAlarmID::ALARM_ID_TD_AIR_TRAP_ILLEGAL_LEVELS : { result = QObject::tr("TD air trap illegal levels." ); break; } /* 79*/ /*0080*/case GuiAlarmID::ALARM_ID_TD_PINCH_VALVE_FAULT : { result = QObject::tr("TD pinch valve fault." ); break; } /* 80*/ /*0081*/case GuiAlarmID::ALARM_ID_TD_VALVE_HOMING_FAILED : { result = QObject::tr("TD pinch valve homing fault." ); break; } /* 81*/ @@ -126,7 +126,7 @@ /*0090*/case GuiAlarmID::ALARM_ID_DD_BC_STATE2_FILL_END_PRESSURE_OUT_OF_RANGE : { result = QObject::tr("DD balance chamber state2 fill end pressure not in range." ); break; } /* 90*/ /*0091*/case GuiAlarmID::ALARM_ID_DD_GEND_HYD_CHAMBER_PRESS_OUT_OF_RANGE : { result = QObject::tr("DD generate dialysate hydraulics chamber ngative pressure out of range." ); break; } /* 91*/ /*0092*/case GuiAlarmID::ALARM_ID_DD_BICARB_FILL_TIMEOUT_FAULT : { result = QObject::tr("DD spent chamber fill timeout fault." ); break; } /* 92*/ -/*0093*/case GuiAlarmID::ALARM_ID_AVAILABLE_93 : { result = QObject::tr("Available alarms." ); break; } /* 93*/ +/*0093*/case GuiAlarmID::ALARM_ID_DD_D79_RINSE_PUMP_SPEED_OUT_OF_RANGE : { result = QObject::tr("DD D79 rinse pump commanded vs measured speed out of tolerance." ); break; } /* 93*/ /*0094*/case GuiAlarmID::ALARM_ID_DD_BC_STATE1_FILL_PRESSURE_DROP_OUT_OF_RANGE : { result = QObject::tr("DD balance chamber state1 fill initiated and pressure drop is not in range." ); break; } /* 94*/ /*0095*/case GuiAlarmID::ALARM_ID_DD_BC_STATE2_FILL_PRESSURE_DROP_OUT_OF_RANGE : { result = QObject::tr("DD balance chamber state2 fill initiated and pressure drop is not in range." ); break; } /* 95*/ /*0096*/case GuiAlarmID::ALARM_ID_TD_TREATMENT_STOPPED_BY_USER : { result = QObject::tr("TD treatment paused by user." ); break; } /* 96*/ @@ -198,7 +198,8 @@ /*0162*/case GuiAlarmID::ALARM_ID_FP_PERMEATE_FLOW_OUT_HIGH_RANGE : { result = QObject::tr("FP permeate flow high fault." ); break; } /* 162*/ /*0163*/case GuiAlarmID::ALARM_ID_FP_PERMEATE_FLOW_OUT_LOW_RANGE : { result = QObject::tr("FP permeate flow low fault." ); break; } /* 163*/ /*0164*/case GuiAlarmID::ALARM_ID_FP_INLET_PRESSURE_LOW_RANGE : { result = QObject::tr("FP inlet pressure low fault." ); break; } /* 164*/ -/*0165*/case GuiAlarmID::NUM_OF_ALARM_IDS : { result = QObject::tr("Number of alarms." ); break; } /* 165*/ +/*0165*/case GuiAlarmID::ALARM_ID_TD_AIR_TRAP_LOWER_TIMEOUT : { result = QObject::tr("TD air trap lower timeout." ); break; } /* 165*/ +/*0166*/case GuiAlarmID::NUM_OF_ALARM_IDS : { result = QObject::tr("Number of alarms." ); break; } /* 166*/ default: result = QObject::tr("ALARM_ID_UNDEFINED [%1]").arg(int(vAlarmID));