Index: AlarmDefs.h =================================================================== diff -u -r0a08bfab79f4b4f3438902008a239f10ac4963a9 -r1e150584ba02ea9f9052bb7c67597ddd763c7384 --- AlarmDefs.h (.../AlarmDefs.h) (revision 0a08bfab79f4b4f3438902008a239f10ac4963a9) +++ AlarmDefs.h (.../AlarmDefs.h) (revision 1e150584ba02ea9f9052bb7c67597ddd763c7384) @@ -220,6 +220,7 @@ ALARM_ID_TD_AUTO_EJECT_EJECTOR_TIMEOUT = 188, ///< TD ejector failed to extend or retract during auto-eject operation ALARM_ID_TD_EJECTOR_POST_TEST_FAILED = 189, ///< TD ejector POST homing failure ALARM_ID_TD_AUTO_LOAD_EJECT_HIGH_BP_TORQUE = 190, ///< TD high blood pump torque during auto-load\eject operation + ALARM_ID_TD_AIR_PUMP_STALL = 191, ///< TD air pump stall detected NUM_OF_ALARM_IDS ///< Number of alarms }; typedef enum Alarm_List ALARM_ID_T; ///< Type for alarm list enumeration @@ -558,6 +559,7 @@ { ALARM_PRIORITY_HIGH, 10, ALM_SRC_TD, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_TD_AUTO_EJECT_EJECTOR_TIMEOUT }, { ALARM_PRIORITY_HIGH, 1, ALM_SRC_TD, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_TD_EJECTOR_POST_TEST_FAILED }, { ALARM_PRIORITY_HIGH, 110, ALM_SRC_TD, FALSE, FALSE, TRUE , FALSE, FALSE, TRUE , TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_TD_AUTO_LOAD_EJECT_HIGH_BP_TORQUE }, + { ALARM_PRIORITY_HIGH, 206, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , ALARM_ID_TD_AIR_PUMP_STALL }, }; // Priority Rank Source Fault DDFault Stops ClrIm NoClr NoRes NoRin NoEnd BlkRB BlkET NoBRcr NoDRcr AutoRes ClrOnly TxLog ID /// Table of alarms and their rank. @@ -710,6 +712,7 @@ { 203, ALARM_ID_TD_ARTERIAL_PRESSURE_HIGH }, { 204, ALARM_ID_TD_TMP_PRESSURE_LOW }, { 205, ALARM_ID_TD_TMP_PRESSURE_HIGH }, + { 206, ALARM_ID_TD_AIR_PUMP_STALL }, { 207, ALARM_ID_TD_SYRINGE_PUMP_SYRINGE_REMOVED }, { 210, ALARM_ID_TD_CARTRIDGE_DOOR_OPENED }, { 290, ALARM_ID_TD_BLOOD_SITTING_WARNING }, @@ -947,7 +950,7 @@ { 162 , ALARM_ID_FP_PERMEATE_FLOW_OUT_HIGH_RANGE , "FP | High Permeate flow | Permeate flow is too high. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | FP Fault: Permeate flow High | Permeate flow is too high from set target flow rate | If the permeate flow is above 25% of set target flow rate for a certain period of time. | "}, { 163 , ALARM_ID_FP_PERMEATE_FLOW_OUT_LOW_RANGE , "FP | low Permeate flow | Permeate flow is too low. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | FP Fault: Permeate flow Low | Permeate flow is too low from set target flow rate | If the permeate flow is above 25% of set target flow rate for a certain period of time. | "}, { 164 , ALARM_ID_FP_INLET_PRESSURE_LOW_RANGE , "FP | low inlet pressure | Inlet pressure is too low. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | FP Fault: Inlet pressure Low | Inlet pressure is too low | If P8 is < 1 PSI | "}, - { 165 , ALARM_ID_TD_AIR_TRAP_LOWER_TIMEOUT , "TD | Blood Pump Stopped: Venous Air Detector | A problem was detected with the venous air detector.\n- Confirm arterial access placement and ensure\nconnections are secure.\n- Treatment must be terminated without rinseback. | Blood Stop: Air Trap Lowering | Air trap lowering timeout during treatment | If the air trap lowering timeout during treatment. | "}, + { 165 , ALARM_ID_TD_AIR_TRAP_LOWER_TIMEOUT , "TD | Blood Pump Stopped: Venous Air Detector | A problem was detected with the venous air detector.\n- Confirm arterial access placement and ensure\nconnections are secure.\n- Treatment must be terminated without rinseback. | Blood Stop: Air Trap Lowering | Air trap lowering timeout during treatment | If the air trap lowering timeout during treatment. | "}, { 166 , ALARM_ID_TD_SYRINGE_PUMP_SELF_TEST_FAILURE , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: Syringe DAC | TD syringe pump self-test failure alarm | If the calibration data that was received from NVDataMgmt and the DAC voltage with syringe retracted are not within tol. | "}, { 167 , ALARM_ID_TD_SYRINGE_PUMP_RUNNING_WHILE_BP_OFF_ERROR , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: Syringe Pump On Err | TD syringe pump is running while the BP is off | If the syringe pump is on while the blood pump is off | "}, { 168 , ALARM_ID_TD_SYRINGE_PUMP_FPGA_ADC_FAULT , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: Syringe Pump ADC Com | TD syringe pump ADC error | If the ADC read is not fresh after POST init and the ADC read counter has not changed. | "}, @@ -974,6 +977,7 @@ { 188 , ALARM_ID_TD_AUTO_EJECT_EJECTOR_TIMEOUT , "TD | Service Required: Hemodialysis Device | The ejector did not reach the expected position within the allowed time.\n- The ejector motor may be faulty or optical sensors may be obstructed or faulty.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call Service to report the issue and schedule a repair. | TD Fault: Ejector Timeout | Ejector failed to reach extended or retracted position during auto-eject | If the ejector does not reach the fully extended or fully retracted position within the allowed time during the auto-eject sequence. | "}, { 189 , ALARM_ID_TD_EJECTOR_POST_TEST_FAILED , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call Service to report the issue and schedule a repair. | TD POST: Ejector Homing | TD ejector did not reach the fully retracted position within the allowed time during power-on self-test | If the ejector does not reach the fully retracted position within allowed time during the power-on self-test. | "}, { 190 , ALARM_ID_TD_AUTO_LOAD_EJECT_HIGH_BP_TORQUE , "TD | Blood Pump Stopped: Tubing Set Jam | A problem was detected during tube set load/eject.\n- The blood pump is reversing to the home position.\n- Once the pump has returned to home, re-seat the blood tubing set and press Resume to retry loading, or wait for the pump to return to home and retry ejecting.\n- If the problem persists, press End Treatment. | Blood Stop: High BP Torque | Blood pump torque exceeded limit during Auto-Load/Eject one-revolution and tubing set jam suspected | If the measured blood pump torque exceeds TBD mNm during the Auto-Load or Auto-Eject one-revolution forward rotation. | "}, + { 191 , ALARM_ID_TD_AIR_PUMP_STALL , "TD | Air Pump Stall Detected | The air pump is commanded to run but no rotation is detected.\n- Check tubing for blockage or occlusion.\n- Verify pump operation and connections.\n- If issue persists, terminate treatment and inspect system. | Blood Pump: Air Pump Stall | Air pump stall detected during treatment | If the air pump is commanded on and the measured RPM is zero for multiple controller cycles. | "}, }; #endif // manual alarms