Index: AlarmDefs.h =================================================================== diff -u -r141201a69404df10d50fd2166ad4f7032c204e45 -rc723a1d97ef4141a70a01747654e6707e3956118 --- AlarmDefs.h (.../AlarmDefs.h) (revision 141201a69404df10d50fd2166ad4f7032c204e45) +++ AlarmDefs.h (.../AlarmDefs.h) (revision c723a1d97ef4141a70a01747654e6707e3956118) @@ -239,7 +239,7 @@ ALARM_ID_FW_RESERVED_207 = 207, ///< FW reserved for use ALARM_ID_TD_INITIAL_BC_REV_PRIME_LIMIT_REACHED = 208, ///< TD initial rev blood circuit prime limit reached ALARM_ID_TD_INITIAL_BC_REV_PRIME_TIMEOUT = 209, ///< TD initial blood circuit prime timeout - ALARM_ID_FW_RESERVED_210 = 210, ///< FW reserved for use + ALARM_ID_TD_PRIME_COMPLETE = 210, ///< TD prime complete ALARM_ID_FW_RESERVED_211 = 211, ///< FW reserved for use ALARM_ID_FW_RESERVED_212 = 212, ///< FW reserved for use ALARM_ID_FW_RESERVED_213 = 213, ///< FW reserved for use @@ -715,7 +715,7 @@ { ALARM_PRIORITY_LOW, 999, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_FW_RESERVED_207 }, { ALARM_PRIORITY_HIGH, 293, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_TD_INITIAL_BC_REV_PRIME_LIMIT_REACHED }, { ALARM_PRIORITY_HIGH, 294, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_TD_INITIAL_BC_REV_PRIME_TIMEOUT }, - { ALARM_PRIORITY_LOW, 999, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_FW_RESERVED_210 }, + { ALARM_PRIORITY_LOW, 853, ALM_SRC_TD, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_TD_PRIME_COMPLETE }, { ALARM_PRIORITY_LOW, 999, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_FW_RESERVED_211 }, { ALARM_PRIORITY_LOW, 999, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_FW_RESERVED_212 }, { ALARM_PRIORITY_LOW, 999, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_FW_RESERVED_213 }, @@ -999,6 +999,7 @@ { 745, ALARM_ID_TD_SYRINGE_DETECTED }, { 850, ALARM_ID_BATTERY_LOW }, { 852, ALARM_ID_TD_AC_POWER_LOST }, + { 853, ALARM_ID_TD_PRIME_COMPLETE }, { 999, ALARM_ID_DD_AVAILABLE_1 }, { 999, ALARM_ID_DD_AVAILABLE_2 }, { 999, ALARM_ID_UI_RESERVED_116 }, @@ -1023,7 +1024,6 @@ { 999, ALARM_ID_FW_RESERVED_205 }, { 999, ALARM_ID_FW_RESERVED_206 }, { 999, ALARM_ID_FW_RESERVED_207 }, - { 999, ALARM_ID_FW_RESERVED_210 }, { 999, ALARM_ID_FW_RESERVED_211 }, { 999, ALARM_ID_FW_RESERVED_212 }, { 999, ALARM_ID_FW_RESERVED_213 }, @@ -1355,7 +1355,7 @@ { 207 , ALARM_ID_FW_RESERVED_207 , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: RESERVED | RESERVED | RESERVED | "}, { 208 , ALARM_ID_TD_INITIAL_BC_REV_PRIME_LIMIT_REACHED , "TD | Prime Paused: Check Saline Line | The system has repeatedly paused priming to relieve negative pressure in the venous line.\n- Check that the saline line is not clamped or kinked.\n- Check that the saline bag is not empty.\n- Resume priming once checked, or end treatment. | Prime: BC: Venous Line, Retry Limit | Venous pressure (H14) reached the neg pressure pause limit, possibly indicating a clamped or occluded saline/H14 line. | During Blood Circuit: Venous Line prime state, when the negative pressure pause/equalize cycle has occurred 3 times. | "}, { 209 , ALARM_ID_TD_INITIAL_BC_REV_PRIME_TIMEOUT , "TD | Prime Timeout: Venous Line | Priming the venous line and air trap did not complete within the expected time.\n- Check the saline line and connections.\n- Resume priming, or end treatment. | Prime: BC: Venous Line, Timeout | Blood Circuit: Venous Line state failed to complete within 40 seconds, excluding time spent paused for pressure equalization. | During Blood Circuit: Venous Line prime state, when the state has been active for more than 40 seconds, excluding paused time. | "}, - { 210 , ALARM_ID_FW_RESERVED_210 , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: RESERVED | RESERVED | RESERVED | "}, + { 210 , ALARM_ID_TD_PRIME_COMPLETE , "TD | Prime Complete | Priming completed, click ok to enter rx. | TD prime complete | | Prime completed | "}, { 211 , ALARM_ID_FW_RESERVED_211 , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: RESERVED | RESERVED | RESERVED | "}, { 212 , ALARM_ID_FW_RESERVED_212 , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: RESERVED | RESERVED | RESERVED | "}, { 213 , ALARM_ID_FW_RESERVED_213 , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: RESERVED | RESERVED | RESERVED | "},