Index: AlarmDefs.h =================================================================== diff -u -r3db3280c153f78815041a38e69d692c31e99ec65 -rf23a62567aa86da41eb79ee8fdd97d8e58c92beb --- AlarmDefs.h (.../AlarmDefs.h) (revision 3db3280c153f78815041a38e69d692c31e99ec65) +++ AlarmDefs.h (.../AlarmDefs.h) (revision f23a62567aa86da41eb79ee8fdd97d8e58c92beb) @@ -299,9 +299,9 @@ ALARM_ID_FW_RESERVED_267 = 267, ///< FW reserved for use ALARM_ID_FW_RESERVED_268 = 268, ///< FW reserved for use ALARM_ID_FW_RESERVED_269 = 269, ///< FW reserved for use - ALARM_ID_FW_RESERVED_270 = 270, ///< FW reserved for use - ALARM_ID_FW_RESERVED_271 = 271, ///< FW reserved for use - ALARM_ID_FW_RESERVED_272 = 272, ///< FW reserved for use + ALARM_ID_DD_PRE_GEN_CHAMBER_C_FILL_TIMEOUT = 270, ///< DD Pre Gen Chamber C fill timer + ALARM_ID_DD_PRE_GEN_D9_PRESSURE = 271, ///< DD Pre Gen D9 pressure out of range + ALARM_ID_DD_PRE_GEN_D18_PRESSURE = 272, ///< DD Pre Gen D18 pressure out of range ALARM_ID_FW_RESERVED_273 = 273, ///< FW reserved for use ALARM_ID_FW_RESERVED_274 = 274, ///< FW reserved for use ALARM_ID_FW_RESERVED_275 = 275, ///< FW reserved for use @@ -775,9 +775,9 @@ { ALARM_PRIORITY_LOW, 999, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_FW_RESERVED_267 }, { ALARM_PRIORITY_LOW, 999, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_FW_RESERVED_268 }, { ALARM_PRIORITY_LOW, 999, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_FW_RESERVED_269 }, - { ALARM_PRIORITY_LOW, 999, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_FW_RESERVED_270 }, - { ALARM_PRIORITY_LOW, 999, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_FW_RESERVED_271 }, - { ALARM_PRIORITY_LOW, 999, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_FW_RESERVED_272 }, + { ALARM_PRIORITY_LOW, 999, ALM_SRC_DD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_DD_PRE_GEN_CHAMBER_C_FILL_TIMEOUT }, + { ALARM_PRIORITY_LOW, 999, ALM_SRC_DD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_DD_PRE_GEN_D9_PRESSURE }, + { ALARM_PRIORITY_LOW, 999, ALM_SRC_DD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_DD_PRE_GEN_D18_PRESSURE }, { ALARM_PRIORITY_LOW, 999, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_FW_RESERVED_273 }, { ALARM_PRIORITY_LOW, 999, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_FW_RESERVED_274 }, { ALARM_PRIORITY_LOW, 999, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_FW_RESERVED_275 }, @@ -1081,9 +1081,9 @@ { 999, ALARM_ID_FW_RESERVED_267 }, { 999, ALARM_ID_FW_RESERVED_268 }, { 999, ALARM_ID_FW_RESERVED_269 }, - { 999, ALARM_ID_FW_RESERVED_270 }, - { 999, ALARM_ID_FW_RESERVED_271 }, - { 999, ALARM_ID_FW_RESERVED_272 }, + { 999, ALARM_ID_DD_PRE_GEN_CHAMBER_C_FILL_TIMEOUT }, + { 999, ALARM_ID_DD_PRE_GEN_D9_PRESSURE }, + { 999, ALARM_ID_DD_PRE_GEN_D18_PRESSURE }, { 999, ALARM_ID_FW_RESERVED_273 }, { 999, ALARM_ID_FW_RESERVED_274 }, { 999, ALARM_ID_FW_RESERVED_275 }, @@ -1415,9 +1415,9 @@ { 267 , ALARM_ID_FW_RESERVED_267 , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: RESERVED | RESERVED | RESERVED | "}, { 268 , ALARM_ID_FW_RESERVED_268 , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: RESERVED | RESERVED | RESERVED | "}, { 269 , ALARM_ID_FW_RESERVED_269 , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: RESERVED | RESERVED | RESERVED | "}, - { 270 , ALARM_ID_FW_RESERVED_270 , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: RESERVED | RESERVED | RESERVED | "}, - { 271 , ALARM_ID_FW_RESERVED_271 , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: RESERVED | RESERVED | RESERVED | "}, - { 272 , ALARM_ID_FW_RESERVED_272 , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: RESERVED | RESERVED | RESERVED | "}, + { 270 , ALARM_ID_DD_PRE_GEN_CHAMBER_C_FILL_TIMEOUT , "DD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: RESERVED | RESERVED | RESERVED | "}, + { 271 , ALARM_ID_DD_PRE_GEN_D9_PRESSURE , "DD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: RESERVED | RESERVED | RESERVED | "}, + { 272 , ALARM_ID_DD_PRE_GEN_D18_PRESSURE , "DD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: RESERVED | RESERVED | RESERVED | "}, { 273 , ALARM_ID_FW_RESERVED_273 , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: RESERVED | RESERVED | RESERVED | "}, { 274 , ALARM_ID_FW_RESERVED_274 , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: RESERVED | RESERVED | RESERVED | "}, { 275 , ALARM_ID_FW_RESERVED_275 , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: RESERVED | RESERVED | RESERVED | "},