Index: AlarmDefs.h =================================================================== diff -u -r439b3c6730f73a0f26a5ea8ce82e3e9326e7060f -r50acbf24a2e073a5ae9c58cd8660973357ac5d0e --- AlarmDefs.h (.../AlarmDefs.h) (revision 439b3c6730f73a0f26a5ea8ce82e3e9326e7060f) +++ AlarmDefs.h (.../AlarmDefs.h) (revision 50acbf24a2e073a5ae9c58cd8660973357ac5d0e) @@ -198,8 +198,9 @@ ALARM_ID_DD_NVM_INVALID_SYSTEM_RECORD_CRC = 166, ///< DD invalid NVM System record ALARM_ID_DD_NVM_INVALID_SERVICE_RECORD_CRC = 167, ///< DD invalid NVM Service record ALARM_ID_DD_NVM_INVALID_CALIBRATION_RECORD_CRC = 168, ///< DD invalid NVM calibration record - ALARM_ID_DD_NVM_INVALID_USAGE_RECORD_CRC = 169, ///< DD invalid NVM Usage Info record - ALARM_ID_DD_NVM_INVALID_SERIAL_NUMBER = 170, ///< DD invalid serial number + ALARM_ID_DD_NVM_INVALID_INSTITUTIONAL_RECORD_CRC = 169, ///< DD invalid NVM institutional record + ALARM_ID_DD_NVM_INVALID_USAGE_RECORD_CRC = 170, ///< DD invalid NVM Usage Info record + ALARM_ID_DD_NVM_INVALID_SERIAL_NUMBER = 171, ///< DD invalid serial number NUM_OF_ALARM_IDS ///< Number of alarms }; typedef enum Alarm_List ALARM_ID_T; ///< Type for alarm list enumeration @@ -513,6 +514,7 @@ { ALARM_PRIORITY_HIGH, 2, ALM_SRC_DD, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, ALARM_ID_DD_NVM_INVALID_SYSTEM_RECORD_CRC }, { ALARM_PRIORITY_HIGH, 2, ALM_SRC_DD, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, ALARM_ID_DD_NVM_INVALID_SERVICE_RECORD_CRC }, { ALARM_PRIORITY_HIGH, 2, ALM_SRC_DD, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, ALARM_ID_DD_NVM_INVALID_CALIBRATION_RECORD_CRC }, + { ALARM_PRIORITY_HIGH, 2, ALM_SRC_DD, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, ALARM_ID_DD_NVM_INVALID_INSTITUTIONAL_RECORD_CRC }, { ALARM_PRIORITY_HIGH, 2, ALM_SRC_DD, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, ALARM_ID_DD_NVM_INVALID_USAGE_RECORD_CRC }, { ALARM_PRIORITY_HIGH, 2, ALM_SRC_DD, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, ALARM_ID_DD_NVM_INVALID_SERIAL_NUMBER }, }; // Priority Rank Source Fault DDFault Stops ClrIm NoClr NoRes NoRin NoEnd BlkRB BlkET NoBRcr NoDRcr AutoRes ClrOnly TxLog ID @@ -547,6 +549,7 @@ { 2, ALARM_ID_DD_NVM_INVALID_SYSTEM_RECORD_CRC }, { 2, ALARM_ID_DD_NVM_INVALID_SERVICE_RECORD_CRC }, { 2, ALARM_ID_DD_NVM_INVALID_CALIBRATION_RECORD_CRC }, + { 2, ALARM_ID_DD_NVM_INVALID_INSTITUTIONAL_RECORD_CRC }, { 2, ALARM_ID_DD_NVM_INVALID_USAGE_RECORD_CRC }, { 2, ALARM_ID_DD_NVM_INVALID_SERIAL_NUMBER }, { 10, ALARM_ID_TD_SOFTWARE_FAULT }, @@ -887,7 +890,8 @@ { 165 , ALARM_ID_TD_AIR_TRAP_LOWER_TIMEOUT , "TD | Blood Pump Stopped: Venous Air Detector | A problem was detected with the venous air detector.\n- Confirm arterial access placement and ensure\nconnections are secure.\n- Treatment must be terminated without rinseback. | Blood Stop: Air Trap Lowering | Air trap lowering timeout during treatment | If the air trap lowering timeout during treatment. | "}, { 166 , ALARM_ID_DD_NVM_INVALID_SYSTEM_RECORD_CRC , "DD | Service Required: Dialysate Device | A problem was detected with the dialysate device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | DD POST: Sys Rec NVRAM CRC | DD invalid system record | If the calculated CRC of the DD system record image does not match the expected CRC. | "}, { 167 , ALARM_ID_DD_NVM_INVALID_SERVICE_RECORD_CRC , "DD | Service Required: Dialysate Device | A problem was detected with the dialysate device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | DD POST: Serv Rec NVRAM CRC | DD invalid service record | If the calculated CRC of the DD service record image does not match the expected CRC. | "}, - { 168 , ALARM_ID_DD_NVM_INVALID_CALIBRATION_RECORD_CRC , "DD | Service Required: Dialysate Device | A problem was detected with the dialysate device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | DD POST: Cal NVRAM CRC | DD non-volatile system group invalid record CRC | If the DD NVDATAMGMT CAL group calculated CRC does not matched the expected CRC. | "}, + { 168 , ALARM_ID_DD_NVM_INVALID_CALIBRATION_RECORD_CRC , "DD | Service Required: Dialysate Device | A problem was detected with the dialysate device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | DD POST: Cal NVRAM CRC | DD non-volatile calibration group invalid record CRC | If the DD NVM Calibration group calculated CRC does not matched the expected CRC. | "}, + { 168 , ALARM_ID_DD_NVM_INVALID_INSTITUTIONAL_RECORD_CRC , "DD | Service Required: Dialysate Device | A problem was detected with the dialysate device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | DD POST: Instit NVRAM CRC | DD non-volatile institutional group invalid record CRC | If the DD NVM Institutional group calculated CRC does not matched the expected CRC. | "}, { 169 , ALARM_ID_DD_NVM_INVALID_USAGE_RECORD_CRC , "DD | Service Required: Dialysate Device | A problem was detected with the dialysate device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | DD POST: Usage Rec NVRAM CRC | DD non-volatile usage information group invalid record CRC | If the DD usage information record's CRC does not match the calculated CRC in POST. | "}, { 170 , ALARM_ID_DD_NVM_INVALID_SERIAL_NUMBER , "DD | Service Required: Dialysate Device | A problem was detected with the dialysate device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | DD POST: Serial Number Check | DD invalid serial number | If the DD serial number is empty and does not have any characters. | "}, };