Index: AlarmDefs.h =================================================================== diff -u -r50c3abce8c90232d92aae87baca7d06245cc8d80 -rc030924418f72808e90a2e9e992e43ba2951e440 --- AlarmDefs.h (.../AlarmDefs.h) (revision 50c3abce8c90232d92aae87baca7d06245cc8d80) +++ AlarmDefs.h (.../AlarmDefs.h) (revision c030924418f72808e90a2e9e992e43ba2951e440) @@ -7,8 +7,8 @@ * * @file AlarmDefs.h * -* @author (last) Praneeth Bunne -* @date (last) 07-Aug-2026 +* @author (last) Varshini Nagabooshanam +* @date (last) 19-Aug-2026 * * @author (original) Sean Nash * @date (original) 01-Aug-2024 @@ -230,7 +230,7 @@ ALARM_ID_TD_PRIME_COMPLETED_MEDIUM = 198, ///< TD prime completed medium priority alarm ALARM_ID_TD_REPEATED_AIR_TRAP_LOWER_EVENTS = 199, ///< TD repeated air trap lower events ALARM_ID_TD_TUBE_SET_MISMATCH = 200, ///< TD tubeset mismatch alarm - ALARM_ID_FW_RESERVED_201 = 201, ///< FW reserved for use + ALARM_ID_TD_PRE_TX_HEPARIN_LOAD_SYRINGE = 201, ///< TD Pre-Treatment Load Heparin Syringe ALARM_ID_FW_RESERVED_202 = 202, ///< FW reserved for use ALARM_ID_FW_RESERVED_203 = 203, ///< FW reserved for use ALARM_ID_FW_RESERVED_204 = 204, ///< FW reserved for use @@ -285,19 +285,19 @@ ALARM_ID_FW_RESERVED_253 = 253, ///< FW reserved for use ALARM_ID_FW_RESERVED_254 = 254, ///< FW reserved for use ALARM_ID_FW_RESERVED_255 = 255, ///< FW reserved for use - ALARM_ID_FW_RESERVED_256 = 256, ///< FW reserved for use - ALARM_ID_FW_RESERVED_257 = 257, ///< FW reserved for use - ALARM_ID_FW_RESERVED_258 = 258, ///< FW reserved for use - ALARM_ID_FW_RESERVED_259 = 259, ///< FW reserved for use - ALARM_ID_FW_RESERVED_260 = 260, ///< FW reserved for use - ALARM_ID_FW_RESERVED_261 = 261, ///< FW reserved for use - ALARM_ID_FW_RESERVED_262 = 262, ///< FW reserved for use - ALARM_ID_FW_RESERVED_263 = 263, ///< FW reserved for use - ALARM_ID_FW_RESERVED_264 = 264, ///< FW reserved for use - ALARM_ID_FW_RESERVED_265 = 265, ///< FW reserved for use - ALARM_ID_FW_RESERVED_266 = 266, ///< FW reserved for use - ALARM_ID_FW_RESERVED_267 = 267, ///< FW reserved for use - ALARM_ID_FW_RESERVED_268 = 268, ///< FW reserved for use + ALARM_ID_TD_INVALID_TUBING_SET = 256, ///< TD invalid tubing set + ALARM_ID_TD_INSTALL_NEW_BLOOD_TUBING_SET = 257, ///< TD install new blood tubing set + ALARM_ID_TD_TUBING_SET_NOT_DETECTED = 258, ///< TD no tubing set detected + ALARM_ID_TD_TUBING_SET_AUTHENTICATION_TIMEOUT = 259, ///< TD tubing set authentication timeout + ALARM_ID_TD_PRESSURE_TOO_HIGH_TO_ZERO = 260, ///< TD pressure too high to zero + ALARM_ID_TD_VENOUS_PRESSURIZATION_TIMEOUT = 261, ///< TD venous pressurization timeout + ALARM_ID_TD_VENOUS_PRESSURE_DECAY = 262, ///< TD venous pressure decay failure + ALARM_ID_TD_VENOUS_PRESSURE_LEAK = 263, ///< TD venous pressure leak + ALARM_ID_TD_VENOUS_PRESSURE_RELIEF = 264, ///< TD venous pressure relief failure + ALARM_ID_TD_ARTERIAL_PRESSURIZATION_TIMEOUT = 265, ///< TD arterial pressurization timeout + ALARM_ID_TD_ARTERIAL_PRESSURE_DECAY = 266, ///< TD arterial pressure decay failure + ALARM_ID_TD_ARTERIAL_PRESSURE_LEAK = 267, ///< TD arterial pressure leak + ALARM_ID_TD_ARTERIAL_PRESSURE_RELIEF = 268, ///< TD arterial pressure relief failure ALARM_ID_FW_RESERVED_269 = 269, ///< FW reserved for use ALARM_ID_FW_RESERVED_270 = 270, ///< FW reserved for use ALARM_ID_FW_RESERVED_271 = 271, ///< FW reserved for use @@ -422,7 +422,6 @@ /**@}*/ - #if defined (__ALARM_MGMT_C__) || defined(__ALARM_MGMT_DD_C__) || defined(__ALARM_MGMT_TD_C__) || defined(__ALARM_MGMT_FP_C__) /** @@ -480,7 +479,6 @@ }; typedef struct AlarmTableResponsePayload ALARM_PROP_T; - /// Record defining the ranking of each individual alarm. struct AlarmsRankRecord { @@ -522,7 +520,6 @@ { ALARM_PRIORITY_HIGH, 110, ALM_SRC_DD, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, ALARM_ID_DD_FPGA_COMM_TIMEOUT }, { ALARM_PRIORITY_HIGH, 1, ALM_SRC_TD, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_TD_ALARM_AUDIO_SELF_TEST_FAILURE }, { ALARM_PRIORITY_HIGH, 110, ALM_SRC_DD, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, ALARM_ID_DD_VALVE_CONTROL_FAILURE }, - // Priority Rank Source Fault DDFault Stops ClrIm NoClr NoRes NoRin NoEnd BlkRB BlkET NoBRcr NoDRcr AutoRes ClrOnly TxLog ID { ALARM_PRIORITY_HIGH, 10, ALM_SRC_TD, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_TD_ARTERIAL_SENSOR_TIMEOUT_FAULT }, { ALARM_PRIORITY_HIGH, 10, ALM_SRC_TD, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_TD_VENOUS_SENSOR_TIMEOUT_FAULT }, @@ -705,8 +702,8 @@ { ALARM_PRIORITY_MEDIUM, 590, ALM_SRC_TD, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, ALARM_ID_TD_PRIME_COMPLETED_MEDIUM }, { ALARM_PRIORITY_HIGH, 17, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , ALARM_ID_TD_REPEATED_AIR_TRAP_LOWER_EVENTS }, { ALARM_PRIORITY_MEDIUM, 300, ALM_SRC_TD, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_TD_TUBE_SET_MISMATCH }, + { ALARM_PRIORITY_LOW, 717, ALM_SRC_TD, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, TRUE, TRUE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE, FALSE, ALARM_ID_TD_PRE_TX_HEPARIN_LOAD_SYRINGE }, // Priority Rank Source Fault DDFault Stops ClrIm NoClr NoRes NoRin NoEnd BlkRB BlkET NoBRcr NoDRcr AutoRes ClrOnly TxLog ID - { ALARM_PRIORITY_LOW, 999, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_FW_RESERVED_201 }, { ALARM_PRIORITY_LOW, 999, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_FW_RESERVED_202 }, { ALARM_PRIORITY_LOW, 999, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_FW_RESERVED_203 }, { ALARM_PRIORITY_LOW, 999, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_FW_RESERVED_204 }, @@ -763,19 +760,19 @@ { ALARM_PRIORITY_LOW, 999, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_FW_RESERVED_253 }, { ALARM_PRIORITY_LOW, 999, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_FW_RESERVED_254 }, { ALARM_PRIORITY_LOW, 999, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_FW_RESERVED_255 }, - { ALARM_PRIORITY_LOW, 999, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_FW_RESERVED_256 }, - { ALARM_PRIORITY_LOW, 999, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_FW_RESERVED_257 }, - { ALARM_PRIORITY_LOW, 999, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_FW_RESERVED_258 }, - { ALARM_PRIORITY_LOW, 999, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_FW_RESERVED_259 }, - { ALARM_PRIORITY_LOW, 999, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_FW_RESERVED_260 }, - { ALARM_PRIORITY_LOW, 999, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_FW_RESERVED_261 }, - { ALARM_PRIORITY_LOW, 999, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_FW_RESERVED_262 }, - { ALARM_PRIORITY_LOW, 999, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_FW_RESERVED_263 }, - { ALARM_PRIORITY_LOW, 999, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_FW_RESERVED_264 }, - { ALARM_PRIORITY_LOW, 999, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_FW_RESERVED_265 }, - { ALARM_PRIORITY_LOW, 999, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_FW_RESERVED_266 }, - { ALARM_PRIORITY_LOW, 999, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_FW_RESERVED_267 }, - { ALARM_PRIORITY_LOW, 999, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_FW_RESERVED_268 }, + { ALARM_PRIORITY_LOW, 731, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_TD_INVALID_TUBING_SET }, + { ALARM_PRIORITY_LOW, 718, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_TD_INSTALL_NEW_BLOOD_TUBING_SET }, + { ALARM_PRIORITY_LOW, 719, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_TD_TUBING_SET_NOT_DETECTED }, + { ALARM_PRIORITY_LOW, 720, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_TD_TUBING_SET_AUTHENTICATION_TIMEOUT }, + { ALARM_PRIORITY_LOW, 721, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_TD_PRESSURE_TOO_HIGH_TO_ZERO }, + { ALARM_PRIORITY_LOW, 722, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_TD_VENOUS_PRESSURIZATION_TIMEOUT }, + { ALARM_PRIORITY_LOW, 723, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_TD_VENOUS_PRESSURE_DECAY }, + { ALARM_PRIORITY_LOW, 724, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_TD_VENOUS_PRESSURE_LEAK }, + { ALARM_PRIORITY_LOW, 725, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_TD_VENOUS_PRESSURE_RELIEF }, + { ALARM_PRIORITY_LOW, 726, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_TD_ARTERIAL_PRESSURIZATION_TIMEOUT }, + { ALARM_PRIORITY_LOW, 727, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_TD_ARTERIAL_PRESSURE_DECAY }, + { ALARM_PRIORITY_LOW, 728, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_TD_ARTERIAL_PRESSURE_LEAK }, + { ALARM_PRIORITY_LOW, 729, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_TD_ARTERIAL_PRESSURE_RELIEF }, { ALARM_PRIORITY_LOW, 999, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_FW_RESERVED_269 }, { ALARM_PRIORITY_LOW, 999, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_FW_RESERVED_270 }, { ALARM_PRIORITY_LOW, 999, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_FW_RESERVED_271 }, @@ -1020,7 +1017,21 @@ { 711, ALARM_ID_TD_VENOUS_BUBBLE_SELF_TEST_FAILURE }, { 715, ALARM_ID_TD_SYRINGE_PUMP_NOT_ENOUGH_HEPARIN_ALARM }, { 716, ALARM_ID_TD_SYRINGE_PUMP_OCCLUSION }, + { 717, ALARM_ID_TD_PRE_TX_HEPARIN_LOAD_SYRINGE }, + { 718, ALARM_ID_TD_INSTALL_NEW_BLOOD_TUBING_SET }, + { 719, ALARM_ID_TD_TUBING_SET_NOT_DETECTED }, + { 720, ALARM_ID_TD_TUBING_SET_AUTHENTICATION_TIMEOUT }, + { 721, ALARM_ID_TD_PRESSURE_TOO_HIGH_TO_ZERO }, + { 722, ALARM_ID_TD_VENOUS_PRESSURIZATION_TIMEOUT }, + { 723, ALARM_ID_TD_VENOUS_PRESSURE_DECAY }, + { 724, ALARM_ID_TD_VENOUS_PRESSURE_LEAK }, + { 725, ALARM_ID_TD_VENOUS_PRESSURE_RELIEF }, + { 726, ALARM_ID_TD_ARTERIAL_PRESSURIZATION_TIMEOUT }, + { 727, ALARM_ID_TD_ARTERIAL_PRESSURE_DECAY }, + { 728, ALARM_ID_TD_ARTERIAL_PRESSURE_LEAK }, + { 729, ALARM_ID_TD_ARTERIAL_PRESSURE_RELIEF }, { 730, ALARM_ID_TD_SYRINGE_PUMP_SYRINGE_EMPTY }, + { 731, ALARM_ID_TD_INVALID_TUBING_SET }, { 745, ALARM_ID_TD_SYRINGE_DETECTED }, { 746, ALARM_ID_TD_RECIRC_TIMEOUT_WARNING }, { 850, ALARM_ID_BATTERY_LOW }, @@ -1043,7 +1054,6 @@ { 999, ALARM_ID_UI_RESERVED_128 }, { 999, ALARM_ID_UI_RESERVED_129 }, { 999, ALARM_ID_UI_RESERVED_130 }, - { 999, ALARM_ID_FW_RESERVED_201 }, { 999, ALARM_ID_FW_RESERVED_202 }, { 999, ALARM_ID_FW_RESERVED_203 }, { 999, ALARM_ID_FW_RESERVED_204 }, @@ -1072,19 +1082,6 @@ { 999, ALARM_ID_FW_RESERVED_253 }, { 999, ALARM_ID_FW_RESERVED_254 }, { 999, ALARM_ID_FW_RESERVED_255 }, - { 999, ALARM_ID_FW_RESERVED_256 }, - { 999, ALARM_ID_FW_RESERVED_257 }, - { 999, ALARM_ID_FW_RESERVED_258 }, - { 999, ALARM_ID_FW_RESERVED_259 }, - { 999, ALARM_ID_FW_RESERVED_260 }, - { 999, ALARM_ID_FW_RESERVED_261 }, - { 999, ALARM_ID_FW_RESERVED_262 }, - { 999, ALARM_ID_FW_RESERVED_263 }, - { 999, ALARM_ID_FW_RESERVED_264 }, - { 999, ALARM_ID_FW_RESERVED_265 }, - { 999, ALARM_ID_FW_RESERVED_266 }, - { 999, ALARM_ID_FW_RESERVED_267 }, - { 999, ALARM_ID_FW_RESERVED_268 }, { 999, ALARM_ID_FW_RESERVED_269 }, { 999, ALARM_ID_FW_RESERVED_270 }, { 999, ALARM_ID_FW_RESERVED_271 }, @@ -1348,8 +1345,8 @@ { 198 , ALARM_ID_TD_PRIME_COMPLETED_MEDIUM , "TD | Prime Complete - 30 MIN WARNING | The priming process completed 90 minutes ago. \n- Treatment must begin within 30 minutes or the\npre-treatment process will be terminated.\n- Press Resume/OK to continue. | Process: Pre-Tx Prime Complete | TD prime completed medium priority alarm | In Pre-Treatment Recirculation for 90 minutes | "}, { 199 , ALARM_ID_TD_REPEATED_AIR_TRAP_LOWER_EVENTS , "TD | Blood Pump Stopped: Venous Air Detector | The air trap level required repeated lowering events. \n- Confirm blood tubing connections are secure.\n- Inspect the air trap for abnormal fluid levels. \n- Resume treatment if the condition has been corrected. | Blood Stop: Repeated Air Trap Lower | Repeated air trap lower events detected during treatment | If 5 air trap lower events occur within 5 minutes during treatment. | "}, { 200 , ALARM_ID_TD_TUBE_SET_MISMATCH , "TD | Wrong Tube Set Installed | The installed tube set does not match the selected treatment type. \n- Remove the current tube set.\n- Install the correct tube set for the selected treatment:\n HD or HD with Online Fluid requires an HD tube set.\n HDF requires an HDF tube set. | TD Tube Set Mismatch | TD installed tube set type does not match the selected treatment modality | If the scanned tube set type does not match the tube set type required for the selected treatment modality. | "}, + { 201 , ALARM_ID_TD_PRE_TX_HEPARIN_LOAD_SYRINGE , "UI TD | Load Syringe | Fill Syringe with {140:2:mL:1} of heparin.\n- Connect heparin filled syringe to infusion port.\n- Insert syringe into the syringe pump.\n- Lock heparin syringe in place.\n- Unclamp heparin pinch clamp. | Process: Pre-Tx Load Syringe | User must load the heparin syringe before continuing heparin setup. | While in Pre-Treatment: Heparin Setup: Await Syringe Load Confirmation state. | "}, // Num Alarm ID Device Display Title Instructions Alarm List Title Description Trigger Condition - { 201 , ALARM_ID_FW_RESERVED_201 , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: RESERVED | RESERVED | RESERVED | "}, { 202 , ALARM_ID_FW_RESERVED_202 , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: RESERVED | RESERVED | RESERVED | "}, { 203 , ALARM_ID_FW_RESERVED_203 , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: RESERVED | RESERVED | RESERVED | "}, { 204 , ALARM_ID_FW_RESERVED_204 , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: RESERVED | RESERVED | RESERVED | "}, @@ -1406,19 +1403,19 @@ { 253 , ALARM_ID_FW_RESERVED_253 , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: RESERVED | RESERVED | RESERVED | "}, { 254 , ALARM_ID_FW_RESERVED_254 , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: RESERVED | RESERVED | RESERVED | "}, { 255 , ALARM_ID_FW_RESERVED_255 , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: RESERVED | RESERVED | RESERVED | "}, - { 256 , ALARM_ID_FW_RESERVED_256 , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: RESERVED | RESERVED | RESERVED | "}, - { 257 , ALARM_ID_FW_RESERVED_257 , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: RESERVED | RESERVED | RESERVED | "}, - { 258 , ALARM_ID_FW_RESERVED_258 , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: RESERVED | RESERVED | RESERVED | "}, - { 259 , ALARM_ID_FW_RESERVED_259 , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: RESERVED | RESERVED | RESERVED | "}, - { 260 , ALARM_ID_FW_RESERVED_260 , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: RESERVED | RESERVED | RESERVED | "}, - { 261 , ALARM_ID_FW_RESERVED_261 , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: RESERVED | RESERVED | RESERVED | "}, - { 262 , ALARM_ID_FW_RESERVED_262 , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: RESERVED | RESERVED | RESERVED | "}, - { 263 , ALARM_ID_FW_RESERVED_263 , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: RESERVED | RESERVED | RESERVED | "}, - { 264 , ALARM_ID_FW_RESERVED_264 , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: RESERVED | RESERVED | RESERVED | "}, - { 265 , ALARM_ID_FW_RESERVED_265 , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: RESERVED | RESERVED | RESERVED | "}, - { 266 , ALARM_ID_FW_RESERVED_266 , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: RESERVED | RESERVED | RESERVED | "}, - { 267 , ALARM_ID_FW_RESERVED_267 , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: RESERVED | RESERVED | RESERVED | "}, - { 268 , ALARM_ID_FW_RESERVED_268 , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: RESERVED | RESERVED | RESERVED | "}, + { 256 , ALARM_ID_TD_INVALID_TUBING_SET , "TD | Invalid Blood Tubing Set | A problem has been detected during self-test.\n- The installed blood tubing set is not valid.\n- Install a valid blood tubing set intended for the selected treatment modality. | Process: Pre-Tx Dry Self-Test | TD detected invalid tubing set during authentication | If authentication response indicates the tubing set is invalid. | "}, + { 257 , ALARM_ID_TD_INSTALL_NEW_BLOOD_TUBING_SET , "TD | Install New Blood Tubing Set | A problem has been detected during self-test.\n- Fluid detected in the tubing set or no valid tubing set installed.\n- Install a new, unused blood tubing set and ensure proper installation. | Process: Pre-Tx Dry Self-Test | TD detected used, wet, or missing blood tubing set | If bubble is detected, air trap levels indicate fluid, or barcode scan fails. | "}, + { 258 , ALARM_ID_TD_TUBING_SET_NOT_DETECTED , "TD | No Blood Tubing Set Detected | A problem has been detected during self-test.\n- No blood tubing set detected in the system.\n- Install a blood tubing set and ensure proper placement. | Process: Pre-Tx Dry Self-Test | TD did not detect tubing set during verification | If no tubing set is detected during tube set loaded check. | "}, + { 259 , ALARM_ID_TD_TUBING_SET_AUTHENTICATION_TIMEOUT , "TD | Tubing Set Authentication Timeout | A problem has been detected during self-test.\n- Authentication response not received.\n- Retry or check system communication. | Process: Pre-Tx Dry Self-Test | TD did not receive authentication response from UI | If no authentication response is received within timeout period. | "}, + { 260 , ALARM_ID_TD_PRESSURE_TOO_HIGH_TO_ZERO , "TD | Pressure Too High to Zero | A problem has been detected during self-test.\n- Pressure levels are too high to perform sensor zeroing.\n- Ensure system is open to atmosphere and retry. | Process: Pre-Tx Dry Self-Test | TD detected high pressure during zeroing | If arterial or venous pressure ≥ 15 mmHg during pressure sensor normal setup. | "}, + { 261 , ALARM_ID_TD_VENOUS_PRESSURIZATION_TIMEOUT , "TD | Venous Pressurization Timeout | A problem has been detected during self-test.\n- Venous pressure did not reach required level.\n- Check tubing connections and system integrity. | Process: Pre-Tx Dry Self-Test | TD failed to reach venous pressure target | If venous pressure does not reach threshold within allowed time. | "}, + { 262 , ALARM_ID_TD_VENOUS_PRESSURE_DECAY , "TD | Venous Pressure Decay | A problem has been detected during self-test.\n- Venous pressure dropped more than expected.\n- Check for leaks or loose connections. | Process: Pre-Tx Dry Self-Test | TD detected excessive venous pressure decay | If venous pressure reduction exceeds allowed tolerance during stabilization. | "}, + { 263 , ALARM_ID_TD_VENOUS_PRESSURE_LEAK , "TD | Venous Pressure Leak | A problem has been detected during self-test.\n- Possible leak in venous line.\n- Inspect tubing and connections. | Process: Pre-Tx Dry Self-Test | TD detected venous pressure leak | If venous pressure difference exceeds tolerance during leak check. | "}, + { 264 , ALARM_ID_TD_VENOUS_PRESSURE_RELIEF , "TD | Venous Pressure Relief Failure | A problem has been detected during self-test.\n- Pressure did not return to baseline.\n- Ensure valves and tubing are functioning properly. | Process: Pre-Tx Dry Self-Test | TD failed venous pressure relief check | If venous pressure does not return within ±5 mmHg after relief. | "}, + { 265 , ALARM_ID_TD_ARTERIAL_PRESSURIZATION_TIMEOUT , "TD | Arterial Pressurization Timeout | A problem has been detected during self-test.\n- Arterial pressure did not reach required level.\n- Check tubing and pump operation. | Process: Pre-Tx Dry Self-Test | TD failed to reach arterial pressure target | If arterial pressure does not reach threshold within allowed time. | "}, + { 266 , ALARM_ID_TD_ARTERIAL_PRESSURE_DECAY , "TD | Arterial Pressure Decay | A problem has been detected during self-test.\n- Arterial pressure dropped more than expected.\n- Check for leaks or loose connections. | Process: Pre-Tx Dry Self-Test | TD detected excessive arterial pressure decay | If arterial pressure reduction exceeds allowed tolerance during stabilization. | "}, + { 267 , ALARM_ID_TD_ARTERIAL_PRESSURE_LEAK , "TD | Arterial Pressure Leak | A problem has been detected during self-test.\n- Possible leak in arterial line.\n- Inspect tubing and connections. | Process: Pre-Tx Dry Self-Test | TD detected arterial pressure leak | If arterial pressure difference exceeds tolerance during leak check. | "}, + { 268 , ALARM_ID_TD_ARTERIAL_PRESSURE_RELIEF , "TD | Arterial Pressure Relief Failure | A problem has been detected during self-test.\n- Pressure did not return to baseline.\n- Ensure valves and tubing are functioning properly. | Process: Pre-Tx Dry Self-Test | TD failed arterial pressure relief check | If arterial pressure does not return within ±5 mmHg after relief. | "}, { 269 , ALARM_ID_FW_RESERVED_269 , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: RESERVED | RESERVED | RESERVED | "}, { 270 , ALARM_ID_FW_RESERVED_270 , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: RESERVED | RESERVED | RESERVED | "}, { 271 , ALARM_ID_FW_RESERVED_271 , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: RESERVED | RESERVED | RESERVED | "},